--/***************************************************************************/ --/** */ --/** This MIB is a superset which includes all of the features in the */ --/** RAMOS family. Some features may not be implemented in certain */ --/** models. */ --/** */ --/***************************************************************************/ -- -- * -- */ CONTEG-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; conteg OBJECT IDENTIFIER ::= { enterprises 3854 } ramosOptima OBJECT IDENTIFIER ::= { conteg 1 } spSummary OBJECT IDENTIFIER ::= { ramosOptima 1 } spStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), warning(3), critical(4), sensorError(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this ramosOptima. The status of the ramosOptima is the worst status of all the sensors under the control of this ramosOptima." ::= { spSummary 2 } spManufName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The manufacturers name" ::= { spSummary 6 } spHelpUrl OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The URL of the web based help" ::= { spSummary 7 } spProductName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The product name" ::= { spSummary 8 } spHostName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The hostname" ::= { spSummary 9 } spSensor OBJECT IDENTIFIER ::= { ramosOptima 2 } ramosOptimaDetail OBJECT IDENTIFIER ::= { spSensor 2 } ramosOptimaEntry OBJECT IDENTIFIER ::= { ramosOptimaDetail 1 } ramosOptimaHost OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Host of this sensor, this is the IP address" ::= { ramosOptimaEntry 1 } ramosOptimaUseDHCP OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To use DHCP enter a 1, to use a static IP address enter a 2" ::= { ramosOptimaEntry 2 } ramosOptimaMAC OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of this system" ::= { ramosOptimaEntry 3 } ramosOptimaSetCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The ramosOptima community string used for snmp Sets" ::= { ramosOptimaEntry 4 } ramosOptimaGetCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The ramosOptima community string used for snmp Gets" ::= { ramosOptimaEntry 5 } ramosOptimaTempTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Temperature Sensor in the SensorArray. Each row in the table contains data for a different Temperature Sensor." ::= { ramosOptimaEntry 16 } ramosOptimaTempEntry OBJECT-TYPE SYNTAX RamosOptimaTempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTempEntry Table" INDEX { ramosOptimaTempIndex } ::= { ramosOptimaTempTable 1 } RamosOptimaTempEntry ::= SEQUENCE { ramosOptimaTempDescription DisplayString, ramosOptimaTempLocation DisplayString, ramosOptimaTempDegree INTEGER, ramosOptimaTempStatus INTEGER, ramosOptimaTempOnline INTEGER, ramosOptimaTempGoOnline INTEGER, ramosOptimaTempHighWarning INTEGER, ramosOptimaTempHighCritical INTEGER, ramosOptimaTempLowWarning INTEGER, ramosOptimaTempLowCritical INTEGER, ramosOptimaTempRearm INTEGER, ramosOptimaTempDegreeType INTEGER, ramosOptimaTempSensorType INTEGER, ramosOptimaTempDegreeRaw INTEGER, ramosOptimaTempEmailTrapLimit INTEGER, ramosOptimaTempEmailTrapSchedule DisplayString, ramosOptimaTempEmailTrapInterval INTEGER, ramosOptimaTempSendNormalTrap INTEGER, ramosOptimaTempDelayError INTEGER, ramosOptimaTempDelayNormal INTEGER, ramosOptimaTempIndex INTEGER, ramosOptimaTempRelayCycleTime INTEGER, ramosOptimaTempRelayOnPort INTEGER, ramosOptimaTempRelayActiveStatus INTEGER, ramosOptimaTempRelayAction INTEGER, ramosOptimaTempEmailInterval INTEGER, ramosOptimaTempIndexCount INTEGER, ramosOptimaTempOffset INTEGER, ramosOptimaTempSirenCycleTime INTEGER, ramosOptimaTempSirenOnPort INTEGER, ramosOptimaTempSirenActiveStatus INTEGER, ramosOptimaTempSirenAction INTEGER, ramosOptimaTempAcknowledgement INTEGER, ramosOptimaTempSirenDelayAlarm INTEGER, ramosOptimaTempURL DisplayString, ramosOptimaTempOpenURL INTEGER, ramosOptimaTempDatacollectType INTEGER, ramosOptimaTempContTimeHighCritical INTEGER, ramosOptimaTempContTimeHighWarning INTEGER, ramosOptimaTempContTimeNormal INTEGER, ramosOptimaTempContTimeLowWarning INTEGER, ramosOptimaTempContTimeLowCritical INTEGER, ramosOptimaTempContTimeSensorError INTEGER, ramosOptimaTempCalendar INTEGER, ramosOptimaThermostatIndex INTEGER, ramosOptimaThermostatDescription DisplayString, ramosOptimaThermostatValue INTEGER, ramosOptimaThermostatOnline INTEGER, ramosOptimaThermostatGoOnline INTEGER, ramosOptimaThermostatMode INTEGER, ramosOptimaThermostatRelayControlPort INTEGER, ramosOptimaThermostatNormalAction1 INTEGER, ramosOptimaThermostatHighLimit1 INTEGER, ramosOptimaThermostatHighLimitAction1 INTEGER, ramosOptimaThermostatLowLimit1 INTEGER, ramosOptimaThermostatLowLimitAction1 INTEGER, ramosOptimaThermostatNormalAction2 INTEGER, ramosOptimaThermostatHighLimit2 INTEGER, ramosOptimaThermostatHighLimitAction2 INTEGER, ramosOptimaThermostatLowLimit2 INTEGER, ramosOptimaThermostatLowLimitAction2 INTEGER, ramosOptimaThermostatEnableTime DisplayString, ramosOptimaTempSendNormalMail INTEGER, ramosOptimaTempSendTrap INTEGER, ramosOptimaTempSendMail INTEGER } ramosOptimaTempDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { ramosOptimaTempEntry 1 } ramosOptimaTempLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this sensor" ::= { ramosOptimaTempEntry 2 } ramosOptimaTempDegree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The degrees in this sensor" ::= { ramosOptimaTempEntry 3 } ramosOptimaTempStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTempEntry 4 } ramosOptimaTempOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTempEntry 5 } ramosOptimaTempGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTempEntry 6 } ramosOptimaTempHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTempEntry 7 } ramosOptimaTempHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTempEntry 8 } ramosOptimaTempLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTempEntry 9 } ramosOptimaTempLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTempEntry 10 } ramosOptimaTempRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTempEntry 11 } ramosOptimaTempDegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTempEntry 12 } ramosOptimaTempSensorType OBJECT-TYPE SYNTAX INTEGER { type1(0), type2(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of temperture sensor" ::= { ramosOptimaTempEntry 13 } ramosOptimaTempDegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SP Only: The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTempEntry 14 } ramosOptimaTempEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { ramosOptimaTempEntry 16 } ramosOptimaTempEmailTrapSchedule OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: Email/trap limit schedule for this sensor" ::= { ramosOptimaTempEntry 17 } ramosOptimaTempEmailTrapInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)." ::= { ramosOptimaTempEntry 18 } ramosOptimaTempSendNormalTrap OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email/trap when sensor goes to normal" ::= { ramosOptimaTempEntry 19 } ramosOptimaTempDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { ramosOptimaTempEntry 20 } ramosOptimaTempDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { ramosOptimaTempEntry 21 } ramosOptimaTempIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the temperature sensor table" ::= { ramosOptimaTempEntry 22 } ramosOptimaTempRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaTempEntry 23 } ramosOptimaTempRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { ramosOptimaTempEntry 24 } ramosOptimaTempRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { ramosOptimaTempEntry 25 } ramosOptimaTempRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaTempEntry 26 } ramosOptimaTempEmailInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "CP8 Only: Minimum time between each email (can be from 0 to 60 minutes)" ::= { ramosOptimaTempEntry 27 } ramosOptimaTempIndexCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Temperature sensor online" ::= { ramosOptimaTempEntry 28 } ramosOptimaTempOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Temperature Offset reading" ::= { ramosOptimaTempEntry 29 } ramosOptimaTempSirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { ramosOptimaTempEntry 30 } ramosOptimaTempSirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { ramosOptimaTempEntry 31 } ramosOptimaTempSirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { ramosOptimaTempEntry 32 } ramosOptimaTempSirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { ramosOptimaTempEntry 33 } ramosOptimaTempAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledged sensor error and stop notification" ::= { ramosOptimaTempEntry 34 } ramosOptimaTempSirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren delay in seconds before start Alarm." ::= { ramosOptimaTempEntry 35 } ramosOptimaTempURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTempEntry 36 } ramosOptimaTempOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTempEntry 37 } ramosOptimaTempDatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTempEntry 38 } ramosOptimaTempContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTempEntry 39 } ramosOptimaTempContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTempEntry 40 } ramosOptimaTempContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTempEntry 41 } ramosOptimaTempContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTempEntry 42 } ramosOptimaTempContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTempEntry 43 } ramosOptimaTempContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTempEntry 44 } ramosOptimaTempCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTempEntry 45 } ramosOptimaThermostatIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTempEntry 46 } ramosOptimaThermostatDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTempEntry 47 } ramosOptimaThermostatValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTempEntry 48 } ramosOptimaThermostatOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTempEntry 49 } ramosOptimaThermostatGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTempEntry 50 } ramosOptimaThermostatMode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTempEntry 51 } ramosOptimaThermostatRelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTempEntry 52 } ramosOptimaThermostatNormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTempEntry 53 } ramosOptimaThermostatHighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTempEntry 54 } ramosOptimaThermostatHighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTempEntry 55 } ramosOptimaThermostatLowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTempEntry 56 } ramosOptimaThermostatLowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTempEntry 57 } ramosOptimaThermostatNormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTempEntry 58 } ramosOptimaThermostatHighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTempEntry 59 } ramosOptimaThermostatHighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTempEntry 60 } ramosOptimaThermostatLowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTempEntry 61 } ramosOptimaThermostatLowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTempEntry 62 } ramosOptimaThermostatEnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTempEntry 63 } ramosOptimaTempSendNormalMail OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email when sensor goes to normal" ::= { ramosOptimaTempEntry 64 } ramosOptimaTempSendTrap OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending trap when sensor change status" ::= { ramosOptimaTempEntry 65 } ramosOptimaTempSendMail OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email when sensor change status" ::= { ramosOptimaTempEntry 66 } ramosOptimaHumidityTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaHumidityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Humidity Sensor in the SensorArray. Each row in the table contains data for a different Humidity Sensor." ::= { ramosOptimaEntry 17 } ramosOptimaHumidityEntry OBJECT-TYPE SYNTAX RamosOptimaHumidityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaHumidityEntry Table" INDEX { ramosOptimaHumidityIndex } ::= { ramosOptimaHumidityTable 1 } RamosOptimaHumidityEntry ::= SEQUENCE { ramosOptimaHumidityDescription DisplayString, ramosOptimaHumidityLocation DisplayString, ramosOptimaHumidityPercent INTEGER, ramosOptimaHumidityStatus INTEGER, ramosOptimaHumidityOnline INTEGER, ramosOptimaHumidityGoOnline INTEGER, ramosOptimaHumidityHighWarning INTEGER, ramosOptimaHumidityHighCritical INTEGER, ramosOptimaHumidityLowWarning INTEGER, ramosOptimaHumidityLowCritical INTEGER, ramosOptimaHumidityRearm INTEGER, ramosOptimaHumidityRaw INTEGER, ramosOptimaHumidityLowVoltage INTEGER, ramosOptimaHumidityHighVoltage INTEGER, ramosOptimaHumidityEmailTrapLimit INTEGER, ramosOptimaHumidityEmailTrapSchedule DisplayString, ramosOptimaHumidityEmailTrapInterval INTEGER, ramosOptimaHumiditySendNormalTrap INTEGER, ramosOptimaHumidityDelayError INTEGER, ramosOptimaHumidityDelayNormal INTEGER, ramosOptimaHumidityIndex INTEGER, ramosOptimaHumidityAtoDAmountMaxVoltage INTEGER, ramosOptimaHumidityAtoDAmountBaseVoltage INTEGER, ramosOptimaHumidityAtoDTypeUnit INTEGER, ramosOptimaHumidityDcUnit DisplayString, ramosOptimaHumidityAtoDJumper INTEGER, ramosOptimaHumidityRelayCycleTime INTEGER, ramosOptimaHumidityRelayOnPort INTEGER, ramosOptimaHumidityRelayActiveStatus INTEGER, ramosOptimaHumidityRelayAction INTEGER, ramosOptimaHumidityEmailInterval INTEGER, ramosOptimaHumidity4to20mAUnit DisplayString, ramosOptimaHumidityIndexCount INTEGER, ramosOptimaHumidityOffset INTEGER, ramosOptimaHumiditySirenCycleTime INTEGER, ramosOptimaHumiditySirenOnPort INTEGER, ramosOptimaHumiditySirenActiveStatus INTEGER, ramosOptimaHumiditySirenAction INTEGER, ramosOptimaHumidityAcknowledgement INTEGER, ramosOptimaHumiditySirenDelayAlarm INTEGER, ramosOptimaHumidityURL DisplayString, ramosOptimaHumidityOpenURL INTEGER, ramosOptimaHumidityDatacollectType INTEGER, ramosOptimaHumidityContTimeHighCritical INTEGER, ramosOptimaHumidityContTimeHighWarning INTEGER, ramosOptimaHumidityContTimeNormal INTEGER, ramosOptimaHumidityContTimeLowWarning INTEGER, ramosOptimaHumidityContTimeLowCritical INTEGER, ramosOptimaHumidityContTimeSensorError INTEGER, ramosOptimaHumidityCalendar INTEGER, ramosOptimaHumiditySendNormalMail INTEGER, ramosOptimaHumiditySendTrap INTEGER, ramosOptimaHumiditySendMail INTEGER } ramosOptimaHumidityDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { ramosOptimaHumidityEntry 1 } ramosOptimaHumidityLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this sensor" ::= { ramosOptimaHumidityEntry 2 } ramosOptimaHumidityPercent OBJECT-TYPE SYNTAX INTEGER (-32768..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The relative humidity percentage measured by this sensor" ::= { ramosOptimaHumidityEntry 3 } ramosOptimaHumidityStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaHumidityEntry 4 } ramosOptimaHumidityOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaHumidityEntry 5 } ramosOptimaHumidityGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaHumidityEntry 6 } ramosOptimaHumidityHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative humidity this sensor measures before it sends a warning" ::= { ramosOptimaHumidityEntry 7 } ramosOptimaHumidityHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative humidity this sensor measures before it becomes critical" ::= { ramosOptimaHumidityEntry 8 } ramosOptimaHumidityLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative humidity this sensor measures before it sends a warning" ::= { ramosOptimaHumidityEntry 9 } ramosOptimaHumidityLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative humidity this sensor measures before it becomes critical" ::= { ramosOptimaHumidityEntry 10 } ramosOptimaHumidityRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The percent relative humidity to rearm the status. For example if status goes from normal to warning, the humidity must go down spAnalogueRearm below warning before the status goes to normal" ::= { ramosOptimaHumidityEntry 11 } ramosOptimaHumidityRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { ramosOptimaHumidityEntry 13 } ramosOptimaHumidityLowVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: The low voltage range for use in AtoD conversion." ::= { ramosOptimaHumidityEntry 14 } ramosOptimaHumidityHighVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: The high voltage range for use in AtoD conversion." ::= { ramosOptimaHumidityEntry 15 } ramosOptimaHumidityEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { ramosOptimaHumidityEntry 17 } ramosOptimaHumidityEmailTrapSchedule OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: Email/trap limit schedule for this sensor" ::= { ramosOptimaHumidityEntry 18 } ramosOptimaHumidityEmailTrapInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)" ::= { ramosOptimaHumidityEntry 19 } ramosOptimaHumiditySendNormalTrap OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email/trap when sensor goes to normal" ::= { ramosOptimaHumidityEntry 20 } ramosOptimaHumidityDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { ramosOptimaHumidityEntry 21 } ramosOptimaHumidityDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { ramosOptimaHumidityEntry 22 } ramosOptimaHumidityIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Humidity sensor table" ::= { ramosOptimaHumidityEntry 23 } ramosOptimaHumidityAtoDAmountMaxVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum scale of DC voltage conversion." ::= { ramosOptimaHumidityEntry 24 } ramosOptimaHumidityAtoDAmountBaseVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The base scale of DC voltage conversion." ::= { ramosOptimaHumidityEntry 25 } ramosOptimaHumidityAtoDTypeUnit OBJECT-TYPE SYNTAX INTEGER { absolute(1), percent(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of scale for use in DC voltage conversion." ::= { ramosOptimaHumidityEntry 26 } ramosOptimaHumidityDcUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Display unit in DC voltage conversion." ::= { ramosOptimaHumidityEntry 27 } ramosOptimaHumidityAtoDJumper OBJECT-TYPE SYNTAX INTEGER { jumperAt-60(-600), jumperAt-40(-400), jumperAt-30(-300), jumperAt-20(-200), jumperAt-10(-100), jumperAt10(100), jumperAt20(200), jumperAt30(300), jumperAt40(400), jumperAt60(600) } ACCESS read-write STATUS mandatory DESCRIPTION "Selected voltage scale (jumper 0) in DC voltage conversion." ::= { ramosOptimaHumidityEntry 28 } ramosOptimaHumidityRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaHumidityEntry 29 } ramosOptimaHumidityRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { ramosOptimaHumidityEntry 30 } ramosOptimaHumidityRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { ramosOptimaHumidityEntry 31 } ramosOptimaHumidityRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaHumidityEntry 32 } ramosOptimaHumidityEmailInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "CP8 Only: Minimum time between each emial (can be from 0 to 60 minutes)" ::= { ramosOptimaHumidityEntry 33 } ramosOptimaHumidity4to20mAUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Display unit in DC voltage conversion." ::= { ramosOptimaHumidityEntry 34 } ramosOptimaHumidityIndexCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Humidity sensor online" ::= { ramosOptimaHumidityEntry 35 } ramosOptimaHumidityOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Humidity Offset reading" ::= { ramosOptimaHumidityEntry 36 } ramosOptimaHumiditySirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { ramosOptimaHumidityEntry 37 } ramosOptimaHumiditySirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { ramosOptimaHumidityEntry 38 } ramosOptimaHumiditySirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { ramosOptimaHumidityEntry 39 } ramosOptimaHumiditySirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { ramosOptimaHumidityEntry 40 } ramosOptimaHumidityAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledged sensor error and stop notification" ::= { ramosOptimaHumidityEntry 41 } ramosOptimaHumiditySirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren delay in seconds before start Alarm." ::= { ramosOptimaHumidityEntry 42 } ramosOptimaHumidityURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaHumidityEntry 43 } ramosOptimaHumidityOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaHumidityEntry 44 } ramosOptimaHumidityDatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaHumidityEntry 45 } ramosOptimaHumidityContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaHumidityEntry 46 } ramosOptimaHumidityContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaHumidityEntry 47 } ramosOptimaHumidityContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaHumidityEntry 48 } ramosOptimaHumidityContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaHumidityEntry 49 } ramosOptimaHumidityContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaHumidityEntry 50 } ramosOptimaHumidityContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaHumidityEntry 51 } ramosOptimaHumidityCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaHumidityEntry 52 } ramosOptimaHumiditySendNormalMail OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email when sensor goes to normal" ::= { ramosOptimaHumidityEntry 53 } ramosOptimaHumiditySendTrap OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending trap when sensor change status" ::= { ramosOptimaHumidityEntry 54 } ramosOptimaHumiditySendMail OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email when sensor change status" ::= { ramosOptimaHumidityEntry 55 } ramosOptimaSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaSwitchEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaEntry 18 } ramosOptimaSwitchEntry OBJECT-TYPE SYNTAX RamosOptimaSwitchEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaSwitchEntry Table" INDEX { ramosOptimaSwitchIndex } ::= { ramosOptimaSwitchTable 1 } RamosOptimaSwitchEntry ::= SEQUENCE { ramosOptimaSwitchDescription DisplayString, ramosOptimaSwitchLocation DisplayString, ramosOptimaSwitchStatus INTEGER, ramosOptimaSwitchOnline INTEGER, ramosOptimaSwitchGoOnline INTEGER, ramosOptimaSwitchDirection INTEGER, ramosOptimaSwitchNormalState INTEGER, ramosOptimaSwitchOutputLevel INTEGER, ramosOptimaSensorType INTEGER, ramosOptimaSwitchEmailTrapLimit INTEGER, ramosOptimaSwitchEmailTrapSchedule DisplayString, ramosOptimaSwitchEmailTrapInterval INTEGER, ramosOptimaSwitchSendNormalTrap INTEGER, ramosOptimaSwitchDelayError INTEGER, ramosOptimaSwitchDelayNormal INTEGER, ramosOptimaSwitchIndex INTEGER, ramosOptimaSwitchRelayCycleTime INTEGER, ramosOptimaSwitchRelayOnPort INTEGER, ramosOptimaSwitchRelayActiveStatus INTEGER, ramosOptimaSwitchRelayAction INTEGER, ramosOptimaSwitchEmailInterval INTEGER, ramosOptimaSwitchRelayOutputVoltStatus INTEGER, ramosOptimaSwitchManualRelayCycleTime INTEGER, ramosOptimaSwitchManualRelayAction INTEGER, ramosOptimaSwitchRelayDescOn DisplayString, ramosOptimaSwitchRelayDescOff DisplayString, ramosOptimaSwitchIndexCount INTEGER, ramosOptimaSwitchSirenCycleTime INTEGER, ramosOptimaSwitchSirenOnPort INTEGER, ramosOptimaSwitchSirenActiveStatus INTEGER, ramosOptimaSwitchSirenAction INTEGER, ramosOptimaSwitchAcknowledgement INTEGER, ramosOptimaSwitchSirenDelayAlarm INTEGER, ramosOptimaSwitchURL DisplayString, ramosOptimaSwitchOpenURL INTEGER, ramosOptimaSwitchContTimeHighCritical INTEGER, ramosOptimaSwitchContTimeNormal INTEGER, ramosOptimaSwitchCalendar INTEGER, ramosOptimaSwitchRelayControlMode INTEGER, ramosOptimaSwitchSirenControlMode INTEGER, ramosOptimaSwitchSendNormalMail INTEGER, ramosOptimaSwitchSendTrap INTEGER, ramosOptimaSwitchSendMail INTEGER, ramosOptimaSwitchWaterRopeLeakLocation INTEGER, ramosOptimaSwitchWaterRopeLength INTEGER, ramosOptimaSwitchWaterRopeUnit INTEGER, ramosOptimaSwitchWaterRopeImpedance INTEGER, ramosOptimaSwitchWaterRopeRaw INTEGER, ramosOptimaSwitchWaterRopeType INTEGER } ramosOptimaSwitchDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { ramosOptimaSwitchEntry 1 } ramosOptimaSwitchLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The physical location of this sensor Switch" ::= { ramosOptimaSwitchEntry 2 } ramosOptimaSwitchStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { ramosOptimaSwitchEntry 3 } ramosOptimaSwitchOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaSwitchEntry 4 } ramosOptimaSwitchGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaSwitchEntry 5 } ramosOptimaSwitchDirection OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a switch to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaSwitchEntry 6 } ramosOptimaSwitchNormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of an input switch. If an input switch is in this state it is normal, else it is critical. An open switch senses +5 volts. A closed switch senses 0 volts." ::= { ramosOptimaSwitchEntry 7 } ramosOptimaSwitchOutputLevel OBJECT-TYPE SYNTAX INTEGER { low(0), high(1) } ACCESS read-write STATUS mandatory DESCRIPTION "An output swith can be set to this level" ::= { ramosOptimaSwitchEntry 8 } ramosOptimaSensorType OBJECT-TYPE SYNTAX INTEGER { temperature(1), fourTo20mA(2), humidity(3), water(4), atod(5), security(6), airflow(8), siren(9), dryContact(10), voltage(12), relay(13), motion(14) } ACCESS read-write STATUS mandatory DESCRIPTION "Enter the type of this Sensor" ::= { ramosOptimaSwitchEntry 9 } ramosOptimaSwitchEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { ramosOptimaSwitchEntry 11 } ramosOptimaSwitchEmailTrapSchedule OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: Email/trap limit schedule for this sensor" ::= { ramosOptimaSwitchEntry 12 } ramosOptimaSwitchEmailTrapInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)" ::= { ramosOptimaSwitchEntry 13 } ramosOptimaSwitchSendNormalTrap OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email/trap when sensor goes to normal" ::= { ramosOptimaSwitchEntry 14 } ramosOptimaSwitchDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { ramosOptimaSwitchEntry 15 } ramosOptimaSwitchDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { ramosOptimaSwitchEntry 16 } ramosOptimaSwitchIndex OBJECT-TYPE SYNTAX INTEGER (0..67) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { ramosOptimaSwitchEntry 17 } ramosOptimaSwitchRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaSwitchEntry 18 } ramosOptimaSwitchRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { ramosOptimaSwitchEntry 19 } ramosOptimaSwitchRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { ramosOptimaSwitchEntry 20 } ramosOptimaSwitchRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaSwitchEntry 21 } ramosOptimaSwitchEmailInterval OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "CP8 Only: Minimum time between each email (can be from 0 to 60 minutes)" ::= { ramosOptimaSwitchEntry 22 } ramosOptimaSwitchRelayOutputVoltStatus OBJECT-TYPE SYNTAX INTEGER { sensorError(7), noVoltagePresent(10), voltagePresent(11) } ACCESS read-only STATUS mandatory DESCRIPTION "SP Only: The current voltage status of the relay" ::= { ramosOptimaSwitchEntry 23 } ramosOptimaSwitchManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaSwitchEntry 24 } ramosOptimaSwitchManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaSwitchEntry 25 } ramosOptimaSwitchRelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaSwitchEntry 26 } ramosOptimaSwitchRelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaSwitchEntry 27 } ramosOptimaSwitchIndexCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Switch sensor online" ::= { ramosOptimaSwitchEntry 28 } ramosOptimaSwitchSirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { ramosOptimaSwitchEntry 29 } ramosOptimaSwitchSirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { ramosOptimaSwitchEntry 30 } ramosOptimaSwitchSirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { ramosOptimaSwitchEntry 31 } ramosOptimaSwitchSirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { ramosOptimaSwitchEntry 32 } ramosOptimaSwitchAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledged sensor error and stop notification" ::= { ramosOptimaSwitchEntry 33 } ramosOptimaSwitchSirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren delay in seconds before start Alarm." ::= { ramosOptimaSwitchEntry 34 } ramosOptimaSwitchURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaSwitchEntry 35 } ramosOptimaSwitchOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaSwitchEntry 36 } ramosOptimaSwitchContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaSwitchEntry 37 } ramosOptimaSwitchContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaSwitchEntry 39 } ramosOptimaSwitchCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaSwitchEntry 43 } ramosOptimaSwitchRelayControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaSwitchEntry 44 } ramosOptimaSwitchSirenControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Siren Control Mode used for selecting the mode to control a siren." ::= { ramosOptimaSwitchEntry 45 } ramosOptimaSwitchSendNormalMail OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email when sensor goes to normal" ::= { ramosOptimaSwitchEntry 46 } ramosOptimaSwitchSendTrap OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending trap when sensor change status" ::= { ramosOptimaSwitchEntry 47 } ramosOptimaSwitchSendMail OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable sending email when sensor change status" ::= { ramosOptimaSwitchEntry 48 } ramosOptimaSwitchWaterRopeLeakLocation OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Location of leakage of water rope sensor." ::= { ramosOptimaSwitchEntry 49 } ramosOptimaSwitchWaterRopeLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of water rope sensor." ::= { ramosOptimaSwitchEntry 50 } ramosOptimaSwitchWaterRopeUnit OBJECT-TYPE SYNTAX INTEGER { meters(0), feet(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Display unit of water rope sensor." ::= { ramosOptimaSwitchEntry 51 } ramosOptimaSwitchWaterRopeImpedance OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Sensing wire impedance per meter value times 100" ::= { ramosOptimaSwitchEntry 52 } ramosOptimaSwitchWaterRopeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Raw value of location or length in ohms" ::= { ramosOptimaSwitchEntry 53 } ramosOptimaSwitchWaterRopeType OBJECT-TYPE SYNTAX INTEGER { custom(0), water(1), fuel(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Water rope sensing cable type" ::= { ramosOptimaSwitchEntry 55 } ramosOptimaOtherSensor OBJECT IDENTIFIER ::= { ramosOptimaEntry 19 } ramosOptimaIRMSSensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 26 } ramosOptimaIRMSSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of RMS current Sensor port." ::= { ramosOptimaIRMSSensor 1 } ramosOptimaIRMSSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaIRMSSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every RMS current Sensor in the SensorArray. Each row in the table contains data for a different RMS current Sensor." ::= { ramosOptimaIRMSSensor 2 } ramosOptimaIRMSSensorEntry OBJECT-TYPE SYNTAX RamosOptimaIRMSSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaIRMSSensorEntry Table" INDEX { ramosOptimaIRMSSensorIndex } ::= { ramosOptimaIRMSSensorTable 1 } RamosOptimaIRMSSensorEntry ::= SEQUENCE { ramosOptimaIRMSSensorIndex INTEGER, ramosOptimaIRMSDescription DisplayString, ramosOptimaIRMSPercent INTEGER, ramosOptimaIRMSStatus INTEGER, ramosOptimaIRMSOnline INTEGER, ramosOptimaIRMSGoOnline INTEGER, ramosOptimaIRMSHighWarning INTEGER, ramosOptimaIRMSHighCritical INTEGER, ramosOptimaIRMSLowWarning INTEGER, ramosOptimaIRMSLowCritical INTEGER, ramosOptimaIRMSRearm INTEGER, ramosOptimaIRMSRaw INTEGER, ramosOptimaIRMSEmailTrapLimit INTEGER, ramosOptimaIRMSDelayError INTEGER, ramosOptimaIRMSDelayNormal INTEGER, ramosOptimaIRMSRelayCycleTime INTEGER, ramosOptimaIRMSRelayOnPort INTEGER, ramosOptimaIRMSRelayActiveStatus INTEGER, ramosOptimaIRMSRelayAction INTEGER, ramosOptimaIRMSSirenCycleTime INTEGER, ramosOptimaIRMSSirenOnPort INTEGER, ramosOptimaIRMSSirenActiveStatus INTEGER, ramosOptimaIRMSSirenAction INTEGER, ramosOptimaIRMSAcknowledgement INTEGER, ramosOptimaIRMSSirenDelayAlarm INTEGER, ramosOptimaIRMSURL DisplayString, ramosOptimaIRMSOpenURL INTEGER, ramosOptimaIRMSDatacollectType INTEGER, ramosOptimaIRMSContTimeHighCritical INTEGER, ramosOptimaIRMSContTimeHighWarning INTEGER, ramosOptimaIRMSContTimeNormal INTEGER, ramosOptimaIRMSContTimeLowWarning INTEGER, ramosOptimaIRMSContTimeLowCritical INTEGER, ramosOptimaIRMSContTimeSensorError INTEGER, ramosOptimaIRMSCalendar INTEGER } ramosOptimaIRMSSensorIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each IRMS sensor port." ::= { ramosOptimaIRMSSensorEntry 1 } ramosOptimaIRMSDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor IRMS" ::= { ramosOptimaIRMSSensorEntry 2 } ramosOptimaIRMSPercent OBJECT-TYPE SYNTAX INTEGER (-32768..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The relative IRMS percentage measured by this sensor" ::= { ramosOptimaIRMSSensorEntry 3 } ramosOptimaIRMSStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaIRMSSensorEntry 4 } ramosOptimaIRMSOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaIRMSSensorEntry 5 } ramosOptimaIRMSGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaIRMSSensorEntry 6 } ramosOptimaIRMSHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative IRMS this sensor measures before it sends a warning" ::= { ramosOptimaIRMSSensorEntry 7 } ramosOptimaIRMSHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative IRMS this sensor measures before it becomes critical" ::= { ramosOptimaIRMSSensorEntry 8 } ramosOptimaIRMSLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative IRMS this sensor measures before it sends a warning" ::= { ramosOptimaIRMSSensorEntry 9 } ramosOptimaIRMSLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative IRMS this sensor measures before it becomes critical" ::= { ramosOptimaIRMSSensorEntry 10 } ramosOptimaIRMSRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The percent relative IRMS to rearm the status. For example if status goes from normal to warning, the IRMS must go down spAnalogueRearm below warning before the status goes to normal" ::= { ramosOptimaIRMSSensorEntry 11 } ramosOptimaIRMSRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { ramosOptimaIRMSSensorEntry 13 } ramosOptimaIRMSEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { ramosOptimaIRMSSensorEntry 17 } ramosOptimaIRMSDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { ramosOptimaIRMSSensorEntry 21 } ramosOptimaIRMSDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { ramosOptimaIRMSSensorEntry 22 } ramosOptimaIRMSRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaIRMSSensorEntry 29 } ramosOptimaIRMSRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { ramosOptimaIRMSSensorEntry 30 } ramosOptimaIRMSRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { ramosOptimaIRMSSensorEntry 31 } ramosOptimaIRMSRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaIRMSSensorEntry 32 } ramosOptimaIRMSSirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { ramosOptimaIRMSSensorEntry 37 } ramosOptimaIRMSSirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { ramosOptimaIRMSSensorEntry 38 } ramosOptimaIRMSSirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { ramosOptimaIRMSSensorEntry 39 } ramosOptimaIRMSSirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { ramosOptimaIRMSSensorEntry 40 } ramosOptimaIRMSAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledged sensor error and stop notification" ::= { ramosOptimaIRMSSensorEntry 41 } ramosOptimaIRMSSirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren delay in seconds before start Alarm." ::= { ramosOptimaIRMSSensorEntry 42 } ramosOptimaIRMSURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaIRMSSensorEntry 43 } ramosOptimaIRMSOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaIRMSSensorEntry 44 } ramosOptimaIRMSDatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaIRMSSensorEntry 45 } ramosOptimaIRMSContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaIRMSSensorEntry 46 } ramosOptimaIRMSContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaIRMSSensorEntry 47 } ramosOptimaIRMSContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaIRMSSensorEntry 48 } ramosOptimaIRMSContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaIRMSSensorEntry 49 } ramosOptimaIRMSContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaIRMSSensorEntry 50 } ramosOptimaIRMSContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaIRMSSensorEntry 51 } ramosOptimaIRMSCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaIRMSSensorEntry 52 } ramosOptimaVRMSSensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 27 } ramosOptimaVRMSSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of RMS voltage Sensor port." ::= { ramosOptimaVRMSSensor 1 } ramosOptimaVRMSSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaVRMSSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every RMS voltage Sensor in the SensorArray. Each row in the table contains data for a different RMS voltage Sensor." ::= { ramosOptimaVRMSSensor 2 } ramosOptimaVRMSSensorEntry OBJECT-TYPE SYNTAX RamosOptimaVRMSSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaVRMSSensorEntry Table" INDEX { ramosOptimaVRMSSensorIndex } ::= { ramosOptimaVRMSSensorTable 1 } RamosOptimaVRMSSensorEntry ::= SEQUENCE { ramosOptimaVRMSSensorIndex INTEGER, ramosOptimaVRMSDescription DisplayString, ramosOptimaVRMSPercent INTEGER, ramosOptimaVRMSStatus INTEGER, ramosOptimaVRMSOnline INTEGER, ramosOptimaVRMSGoOnline INTEGER, ramosOptimaVRMSHighWarning INTEGER, ramosOptimaVRMSHighCritical INTEGER, ramosOptimaVRMSLowWarning INTEGER, ramosOptimaVRMSLowCritical INTEGER, ramosOptimaVRMSRearm INTEGER, ramosOptimaVRMSRaw INTEGER, ramosOptimaVRMSEmailTrapLimit INTEGER, ramosOptimaVRMSDelayError INTEGER, ramosOptimaVRMSDelayNormal INTEGER, ramosOptimaVRMSRelayCycleTime INTEGER, ramosOptimaVRMSRelayOnPort INTEGER, ramosOptimaVRMSRelayActiveStatus INTEGER, ramosOptimaVRMSRelayAction INTEGER, ramosOptimaVRMSSirenCycleTime INTEGER, ramosOptimaVRMSSirenOnPort INTEGER, ramosOptimaVRMSSirenActiveStatus INTEGER, ramosOptimaVRMSSirenAction INTEGER, ramosOptimaVRMSAcknowledgement INTEGER, ramosOptimaVRMSSirenDelayAlarm INTEGER, ramosOptimaVRMSvoltageMode INTEGER, ramosOptimaVRMSURL DisplayString, ramosOptimaVRMSOpenURL INTEGER, ramosOptimaVRMSDatacollectType INTEGER, ramosOptimaVRMSContTimeHighCritical INTEGER, ramosOptimaVRMSContTimeHighWarning INTEGER, ramosOptimaVRMSContTimeNormal INTEGER, ramosOptimaVRMSContTimeLowWarning INTEGER, ramosOptimaVRMSContTimeLowCritical INTEGER, ramosOptimaVRMSContTimeSensorError INTEGER, ramosOptimaVRMSCalendar INTEGER } ramosOptimaVRMSSensorIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each VRMS sensor port." ::= { ramosOptimaVRMSSensorEntry 1 } ramosOptimaVRMSDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor VRMS" ::= { ramosOptimaVRMSSensorEntry 2 } ramosOptimaVRMSPercent OBJECT-TYPE SYNTAX INTEGER (-32768..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The relative VRMS percentage measured by this sensor" ::= { ramosOptimaVRMSSensorEntry 3 } ramosOptimaVRMSStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaVRMSSensorEntry 4 } ramosOptimaVRMSOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaVRMSSensorEntry 5 } ramosOptimaVRMSGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaVRMSSensorEntry 6 } ramosOptimaVRMSHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative VRMS this sensor measures before it sends a warning" ::= { ramosOptimaVRMSSensorEntry 7 } ramosOptimaVRMSHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative VRMS this sensor measures before it becomes critical" ::= { ramosOptimaVRMSSensorEntry 8 } ramosOptimaVRMSLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative VRMS this sensor measures before it sends a warning" ::= { ramosOptimaVRMSSensorEntry 9 } ramosOptimaVRMSLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative VRMS this sensor measures before it becomes critical" ::= { ramosOptimaVRMSSensorEntry 10 } ramosOptimaVRMSRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The percent relative VRMS to rearm the status. For example if status goes from normal to warning, the VRMS must go down spAnalogueRearm below warning before the status goes to normal" ::= { ramosOptimaVRMSSensorEntry 11 } ramosOptimaVRMSRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { ramosOptimaVRMSSensorEntry 13 } ramosOptimaVRMSEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { ramosOptimaVRMSSensorEntry 17 } ramosOptimaVRMSDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { ramosOptimaVRMSSensorEntry 21 } ramosOptimaVRMSDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { ramosOptimaVRMSSensorEntry 22 } ramosOptimaVRMSRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaVRMSSensorEntry 29 } ramosOptimaVRMSRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { ramosOptimaVRMSSensorEntry 30 } ramosOptimaVRMSRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { ramosOptimaVRMSSensorEntry 31 } ramosOptimaVRMSRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaVRMSSensorEntry 32 } ramosOptimaVRMSSirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { ramosOptimaVRMSSensorEntry 37 } ramosOptimaVRMSSirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { ramosOptimaVRMSSensorEntry 38 } ramosOptimaVRMSSirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { ramosOptimaVRMSSensorEntry 39 } ramosOptimaVRMSSirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { ramosOptimaVRMSSensorEntry 40 } ramosOptimaVRMSAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledged sensor error and stop notification" ::= { ramosOptimaVRMSSensorEntry 41 } ramosOptimaVRMSSirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren delay in seconds before start Alarm." ::= { ramosOptimaVRMSSensorEntry 42 } ramosOptimaVRMSvoltageMode OBJECT-TYPE SYNTAX INTEGER { ac-110(110), ac-220(220) } ACCESS read-write STATUS mandatory DESCRIPTION "VRMS Voltage Mode." ::= { ramosOptimaVRMSSensorEntry 43 } ramosOptimaVRMSURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaVRMSSensorEntry 44 } ramosOptimaVRMSOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaVRMSSensorEntry 45 } ramosOptimaVRMSDatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaVRMSSensorEntry 46 } ramosOptimaVRMSContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaVRMSSensorEntry 47 } ramosOptimaVRMSContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaVRMSSensorEntry 48 } ramosOptimaVRMSContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaVRMSSensorEntry 49 } ramosOptimaVRMSContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaVRMSSensorEntry 50 } ramosOptimaVRMSContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaVRMSSensorEntry 51 } ramosOptimaVRMSContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaVRMSSensorEntry 52 } ramosOptimaVRMSCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaVRMSSensorEntry 53 } ramosOptimaEnergySensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 28 } ramosOptimaEnergySensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Energy Sensor port." ::= { ramosOptimaEnergySensor 1 } ramosOptimaEnergySensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaEnergySensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Energy Sensor in the SensorArray. Each row in the table contains data for a different Energy Sensor." ::= { ramosOptimaEnergySensor 2 } ramosOptimaEnergySensorEntry OBJECT-TYPE SYNTAX RamosOptimaEnergySensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaEnergySensorEntry Table" INDEX { ramosOptimaEnergySensorIndex } ::= { ramosOptimaEnergySensorTable 1 } RamosOptimaEnergySensorEntry ::= SEQUENCE { ramosOptimaEnergySensorIndex INTEGER, ramosOptimaEnergyDescription DisplayString, ramosOptimaEnergyPercent INTEGER, ramosOptimaEnergyStatus INTEGER, ramosOptimaEnergyOnline INTEGER, ramosOptimaEnergyGoOnline INTEGER, ramosOptimaEnergyHighWarning INTEGER, ramosOptimaEnergyHighCritical INTEGER, ramosOptimaEnergyLowWarning INTEGER, ramosOptimaEnergyLowCritical INTEGER, ramosOptimaEnergyRearm INTEGER, ramosOptimaEnergyRaw INTEGER, ramosOptimaEnergyEmailTrapLimit INTEGER, ramosOptimaEnergyDelayError INTEGER, ramosOptimaEnergyDelayNormal INTEGER, ramosOptimaEnergyRelayCycleTime INTEGER, ramosOptimaEnergyRelayOnPort INTEGER, ramosOptimaEnergyRelayActiveStatus INTEGER, ramosOptimaEnergyRelayAction INTEGER, ramosOptimaEnergySirenCycleTime INTEGER, ramosOptimaEnergySirenOnPort INTEGER, ramosOptimaEnergySirenActiveStatus INTEGER, ramosOptimaEnergySirenAction INTEGER, ramosOptimaEnergyAcknowledgement INTEGER, ramosOptimaEnergySirenDelayAlarm INTEGER, ramosOptimaEnergyReadingMode INTEGER, ramosOptimaEnergyURL DisplayString, ramosOptimaEnergyOpenURL INTEGER, ramosOptimaEnergyDatacollectType INTEGER, ramosOptimaEnergyContTimeHighCritical INTEGER, ramosOptimaEnergyContTimeHighWarning INTEGER, ramosOptimaEnergyContTimeNormal INTEGER, ramosOptimaEnergyContTimeLowWarning INTEGER, ramosOptimaEnergyContTimeLowCritical INTEGER, ramosOptimaEnergyContTimeSensorError INTEGER, ramosOptimaEnergyCalendar INTEGER } ramosOptimaEnergySensorIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each Energy sensor port." ::= { ramosOptimaEnergySensorEntry 1 } ramosOptimaEnergyDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Energy" ::= { ramosOptimaEnergySensorEntry 2 } ramosOptimaEnergyPercent OBJECT-TYPE SYNTAX INTEGER (-32768..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The relative Energy percentage measured by this sensor" ::= { ramosOptimaEnergySensorEntry 3 } ramosOptimaEnergyStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaEnergySensorEntry 4 } ramosOptimaEnergyOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaEnergySensorEntry 5 } ramosOptimaEnergyGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaEnergySensorEntry 6 } ramosOptimaEnergyHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative Energy this sensor measures before it sends a warning" ::= { ramosOptimaEnergySensorEntry 7 } ramosOptimaEnergyHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative Energy this sensor measures before it becomes critical" ::= { ramosOptimaEnergySensorEntry 8 } ramosOptimaEnergyLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative Energy this sensor measures before it sends a warning" ::= { ramosOptimaEnergySensorEntry 9 } ramosOptimaEnergyLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative Energy this sensor measures before it becomes critical" ::= { ramosOptimaEnergySensorEntry 10 } ramosOptimaEnergyRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The percent relative Energy to rearm the status. For example if status goes from normal to warning, the Energy must go down spAnalogueRearm below warning before the status goes to normal" ::= { ramosOptimaEnergySensorEntry 11 } ramosOptimaEnergyRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { ramosOptimaEnergySensorEntry 13 } ramosOptimaEnergyEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { ramosOptimaEnergySensorEntry 17 } ramosOptimaEnergyDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { ramosOptimaEnergySensorEntry 21 } ramosOptimaEnergyDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { ramosOptimaEnergySensorEntry 22 } ramosOptimaEnergyRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaEnergySensorEntry 29 } ramosOptimaEnergyRelayOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports" ::= { ramosOptimaEnergySensorEntry 30 } ramosOptimaEnergyRelayActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the relay" ::= { ramosOptimaEnergySensorEntry 31 } ramosOptimaEnergyRelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaEnergySensorEntry 32 } ramosOptimaEnergySirenCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren toggle period in seconds for Cycle action." ::= { ramosOptimaEnergySensorEntry 37 } ramosOptimaEnergySirenOnPort OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports" ::= { ramosOptimaEnergySensorEntry 38 } ramosOptimaEnergySirenActiveStatus OBJECT-TYPE SYNTAX INTEGER { highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), anyError(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Sensor status that will activate the siren" ::= { ramosOptimaEnergySensorEntry 39 } ramosOptimaEnergySirenAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the siren will do when the listened to port status turns to the specified active status." ::= { ramosOptimaEnergySensorEntry 40 } ramosOptimaEnergyAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledged sensor error and stop notification" ::= { ramosOptimaEnergySensorEntry 41 } ramosOptimaEnergySirenDelayAlarm OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Siren delay in seconds before start Alarm." ::= { ramosOptimaEnergySensorEntry 42 } ramosOptimaEnergyReadingMode OBJECT-TYPE SYNTAX INTEGER { active(0), apparent(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Energy Meter Reading Mode." ::= { ramosOptimaEnergySensorEntry 43 } ramosOptimaEnergyURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaEnergySensorEntry 44 } ramosOptimaEnergyOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaEnergySensorEntry 45 } ramosOptimaEnergyDatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaEnergySensorEntry 46 } ramosOptimaEnergyContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaEnergySensorEntry 47 } ramosOptimaEnergyContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaEnergySensorEntry 48 } ramosOptimaEnergyContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaEnergySensorEntry 49 } ramosOptimaEnergyContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaEnergySensorEntry 50 } ramosOptimaEnergyContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaEnergySensorEntry 51 } ramosOptimaEnergyContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaEnergySensorEntry 52 } ramosOptimaEnergyCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaEnergySensorEntry 53 } ramosOptimaRelayArraySensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 29 } ramosOptimaRelayArrayPort1 OBJECT IDENTIFIER ::= { ramosOptimaRelayArraySensor 1 } ramosOptimaRelayArrayPort1Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the RelayArray." ::= { ramosOptimaRelayArrayPort1 1 } ramosOptimaRelayArrayPort1Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaRelayArrayPort1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaRelayArrayPort1 2 } ramosOptimaRelayArrayPort1Entry OBJECT-TYPE SYNTAX RamosOptimaRelayArrayPort1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaRelayArrayPort1 Table" INDEX { ramosOptimaRelayArrayPort1Index } ::= { ramosOptimaRelayArrayPort1Table 1 } RamosOptimaRelayArrayPort1Entry ::= SEQUENCE { ramosOptimaRelayArrayPort1Index INTEGER, ramosOptimaRelayArrayPort1Description DisplayString, ramosOptimaRelayArrayPort1Status INTEGER, ramosOptimaRelayArrayPort1Online INTEGER, ramosOptimaRelayArrayPort1GoOnline INTEGER, ramosOptimaRelayArrayPort1NormalState INTEGER, ramosOptimaRelayArrayPort1RelayCycleTime INTEGER, ramosOptimaRelayArrayPort1RelayAction INTEGER, ramosOptimaRelayArrayPort1ManualRelayCycleTime INTEGER, ramosOptimaRelayArrayPort1ManualRelayAction INTEGER, ramosOptimaRelayArrayPort1RelayDescOn DisplayString, ramosOptimaRelayArrayPort1RelayDescOff DisplayString, ramosOptimaRelayArrayPort1URL DisplayString, ramosOptimaRelayArrayPort1OpenURL INTEGER, ramosOptimaRelayArrayPort1ControlMode INTEGER } ramosOptimaRelayArrayPort1Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor RelayArray port." ::= { ramosOptimaRelayArrayPort1Entry 1 } ramosOptimaRelayArrayPort1Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor RelayArray" ::= { ramosOptimaRelayArrayPort1Entry 2 } ramosOptimaRelayArrayPort1Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaRelayArrayPort1Entry 4 } ramosOptimaRelayArrayPort1Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaRelayArrayPort1Entry 5 } ramosOptimaRelayArrayPort1GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaRelayArrayPort1Entry 6 } ramosOptimaRelayArrayPort1NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of RelayArray" ::= { ramosOptimaRelayArrayPort1Entry 7 } ramosOptimaRelayArrayPort1RelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaRelayArrayPort1Entry 18 } ramosOptimaRelayArrayPort1RelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaRelayArrayPort1Entry 21 } ramosOptimaRelayArrayPort1ManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaRelayArrayPort1Entry 24 } ramosOptimaRelayArrayPort1ManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaRelayArrayPort1Entry 25 } ramosOptimaRelayArrayPort1RelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaRelayArrayPort1Entry 26 } ramosOptimaRelayArrayPort1RelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaRelayArrayPort1Entry 27 } ramosOptimaRelayArrayPort1URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sersor URL link." ::= { ramosOptimaRelayArrayPort1Entry 28 } ramosOptimaRelayArrayPort1OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaRelayArrayPort1Entry 29 } ramosOptimaRelayArrayPort1ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaRelayArrayPort1Entry 30 } ramosOptimaRelayArrayPort2 OBJECT IDENTIFIER ::= { ramosOptimaRelayArraySensor 2 } ramosOptimaRelayArrayPort2Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the RelayArray." ::= { ramosOptimaRelayArrayPort2 1 } ramosOptimaRelayArrayPort2Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaRelayArrayPort2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaRelayArrayPort2 2 } ramosOptimaRelayArrayPort2Entry OBJECT-TYPE SYNTAX RamosOptimaRelayArrayPort2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaRelayArrayPort2 Table" INDEX { ramosOptimaRelayArrayPort2Index } ::= { ramosOptimaRelayArrayPort2Table 1 } RamosOptimaRelayArrayPort2Entry ::= SEQUENCE { ramosOptimaRelayArrayPort2Index INTEGER, ramosOptimaRelayArrayPort2Description DisplayString, ramosOptimaRelayArrayPort2Status INTEGER, ramosOptimaRelayArrayPort2Online INTEGER, ramosOptimaRelayArrayPort2GoOnline INTEGER, ramosOptimaRelayArrayPort2NormalState INTEGER, ramosOptimaRelayArrayPort2RelayCycleTime INTEGER, ramosOptimaRelayArrayPort2RelayAction INTEGER, ramosOptimaRelayArrayPort2ManualRelayCycleTime INTEGER, ramosOptimaRelayArrayPort2ManualRelayAction INTEGER, ramosOptimaRelayArrayPort2RelayDescOn DisplayString, ramosOptimaRelayArrayPort2RelayDescOff DisplayString, ramosOptimaRelayArrayPort2URL DisplayString, ramosOptimaRelayArrayPort2OpenURL INTEGER, ramosOptimaRelayArrayPort2ControlMode INTEGER } ramosOptimaRelayArrayPort2Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor RelayArray port." ::= { ramosOptimaRelayArrayPort2Entry 1 } ramosOptimaRelayArrayPort2Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor RelayArray" ::= { ramosOptimaRelayArrayPort2Entry 2 } ramosOptimaRelayArrayPort2Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaRelayArrayPort2Entry 4 } ramosOptimaRelayArrayPort2Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaRelayArrayPort2Entry 5 } ramosOptimaRelayArrayPort2GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaRelayArrayPort2Entry 6 } ramosOptimaRelayArrayPort2NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of RleayArray" ::= { ramosOptimaRelayArrayPort2Entry 7 } ramosOptimaRelayArrayPort2RelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaRelayArrayPort2Entry 18 } ramosOptimaRelayArrayPort2RelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaRelayArrayPort2Entry 21 } ramosOptimaRelayArrayPort2ManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaRelayArrayPort2Entry 24 } ramosOptimaRelayArrayPort2ManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaRelayArrayPort2Entry 25 } ramosOptimaRelayArrayPort2RelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaRelayArrayPort2Entry 26 } ramosOptimaRelayArrayPort2RelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaRelayArrayPort2Entry 27 } ramosOptimaRelayArrayPort2URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link" ::= { ramosOptimaRelayArrayPort2Entry 28 } ramosOptimaRelayArrayPort2OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaRelayArrayPort2Entry 29 } ramosOptimaRelayArrayPort2ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaRelayArrayPort2Entry 30 } ramosOptimaRelayArrayPort3 OBJECT IDENTIFIER ::= { ramosOptimaRelayArraySensor 3 } ramosOptimaRelayArrayPort3Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the RelayArray." ::= { ramosOptimaRelayArrayPort3 1 } ramosOptimaRelayArrayPort3Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaRelayArrayPort3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaRelayArrayPort3 2 } ramosOptimaRelayArrayPort3Entry OBJECT-TYPE SYNTAX RamosOptimaRelayArrayPort3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaRelayArrayPort3 Table" INDEX { ramosOptimaRelayArrayPort3Index } ::= { ramosOptimaRelayArrayPort3Table 1 } RamosOptimaRelayArrayPort3Entry ::= SEQUENCE { ramosOptimaRelayArrayPort3Index INTEGER, ramosOptimaRelayArrayPort3Description DisplayString, ramosOptimaRelayArrayPort3Status INTEGER, ramosOptimaRelayArrayPort3Online INTEGER, ramosOptimaRelayArrayPort3GoOnline INTEGER, ramosOptimaRelayArrayPort3NormalState INTEGER, ramosOptimaRelayArrayPort3RelayCycleTime INTEGER, ramosOptimaRelayArrayPort3RelayAction INTEGER, ramosOptimaRelayArrayPort3ManualRelayCycleTime INTEGER, ramosOptimaRelayArrayPort3ManualRelayAction INTEGER, ramosOptimaRelayArrayPort3RelayDescOn DisplayString, ramosOptimaRelayArrayPort3RelayDescOff DisplayString, ramosOptimaRelayArrayPort3URL DisplayString, ramosOptimaRelayArrayPort3OpenURL INTEGER, ramosOptimaRelayArrayPort3ControlMode INTEGER } ramosOptimaRelayArrayPort3Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor RelayArray port." ::= { ramosOptimaRelayArrayPort3Entry 1 } ramosOptimaRelayArrayPort3Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor RelayArray" ::= { ramosOptimaRelayArrayPort3Entry 2 } ramosOptimaRelayArrayPort3Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaRelayArrayPort3Entry 4 } ramosOptimaRelayArrayPort3Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaRelayArrayPort3Entry 5 } ramosOptimaRelayArrayPort3GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaRelayArrayPort3Entry 6 } ramosOptimaRelayArrayPort3NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of RleayArray" ::= { ramosOptimaRelayArrayPort3Entry 7 } ramosOptimaRelayArrayPort3RelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaRelayArrayPort3Entry 18 } ramosOptimaRelayArrayPort3RelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaRelayArrayPort3Entry 21 } ramosOptimaRelayArrayPort3ManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaRelayArrayPort3Entry 24 } ramosOptimaRelayArrayPort3ManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaRelayArrayPort3Entry 25 } ramosOptimaRelayArrayPort3RelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaRelayArrayPort3Entry 26 } ramosOptimaRelayArrayPort3RelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaRelayArrayPort3Entry 27 } ramosOptimaRelayArrayPort3URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaRelayArrayPort3Entry 28 } ramosOptimaRelayArrayPort3OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaRelayArrayPort3Entry 29 } ramosOptimaRelayArrayPort3ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaRelayArrayPort3Entry 30 } ramosOptimaRelayArrayPort4 OBJECT IDENTIFIER ::= { ramosOptimaRelayArraySensor 4 } ramosOptimaRelayArrayPort4Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the RelayArray." ::= { ramosOptimaRelayArrayPort4 1 } ramosOptimaRelayArrayPort4Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaRelayArrayPort4Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaRelayArrayPort4 2 } ramosOptimaRelayArrayPort4Entry OBJECT-TYPE SYNTAX RamosOptimaRelayArrayPort4Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaRelayArrayPort4 Table" INDEX { ramosOptimaRelayArrayPort4Index } ::= { ramosOptimaRelayArrayPort4Table 1 } RamosOptimaRelayArrayPort4Entry ::= SEQUENCE { ramosOptimaRelayArrayPort4Index INTEGER, ramosOptimaRelayArrayPort4Description DisplayString, ramosOptimaRelayArrayPort4Status INTEGER, ramosOptimaRelayArrayPort4Online INTEGER, ramosOptimaRelayArrayPort4GoOnline INTEGER, ramosOptimaRelayArrayPort4NormalState INTEGER, ramosOptimaRelayArrayPort4RelayCycleTime INTEGER, ramosOptimaRelayArrayPort4RelayAction INTEGER, ramosOptimaRelayArrayPort4ManualRelayCycleTime INTEGER, ramosOptimaRelayArrayPort4ManualRelayAction INTEGER, ramosOptimaRelayArrayPort4RelayDescOn DisplayString, ramosOptimaRelayArrayPort4RelayDescOff DisplayString, ramosOptimaRelayArrayPort4URL DisplayString, ramosOptimaRelayArrayPort4OpenURL INTEGER, ramosOptimaRelayArrayPort4ControlMode INTEGER } ramosOptimaRelayArrayPort4Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor RelayArray port." ::= { ramosOptimaRelayArrayPort4Entry 1 } ramosOptimaRelayArrayPort4Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor RelayArray" ::= { ramosOptimaRelayArrayPort4Entry 2 } ramosOptimaRelayArrayPort4Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaRelayArrayPort4Entry 4 } ramosOptimaRelayArrayPort4Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaRelayArrayPort4Entry 5 } ramosOptimaRelayArrayPort4GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaRelayArrayPort4Entry 6 } ramosOptimaRelayArrayPort4NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of RleayArray" ::= { ramosOptimaRelayArrayPort4Entry 7 } ramosOptimaRelayArrayPort4RelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaRelayArrayPort4Entry 18 } ramosOptimaRelayArrayPort4RelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaRelayArrayPort4Entry 21 } ramosOptimaRelayArrayPort4ManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaRelayArrayPort4Entry 24 } ramosOptimaRelayArrayPort4ManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaRelayArrayPort4Entry 25 } ramosOptimaRelayArrayPort4RelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaRelayArrayPort4Entry 26 } ramosOptimaRelayArrayPort4RelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaRelayArrayPort4Entry 27 } ramosOptimaRelayArrayPort4URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaRelayArrayPort4Entry 28 } ramosOptimaRelayArrayPort4OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaRelayArrayPort4Entry 29 } ramosOptimaRelayArrayPort4ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaRelayArrayPort4Entry 30 } ramosOptimaRelayArrayPort5 OBJECT IDENTIFIER ::= { ramosOptimaRelayArraySensor 5 } ramosOptimaRelayArrayPort5Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the RelayArray." ::= { ramosOptimaRelayArrayPort5 1 } ramosOptimaRelayArrayPort5Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaRelayArrayPort5Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaRelayArrayPort5 2 } ramosOptimaRelayArrayPort5Entry OBJECT-TYPE SYNTAX RamosOptimaRelayArrayPort5Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaRelayArrayPort5 Table" INDEX { ramosOptimaRelayArrayPort5Index } ::= { ramosOptimaRelayArrayPort5Table 1 } RamosOptimaRelayArrayPort5Entry ::= SEQUENCE { ramosOptimaRelayArrayPort5Index INTEGER, ramosOptimaRelayArrayPort5Description DisplayString, ramosOptimaRelayArrayPort5Status INTEGER, ramosOptimaRelayArrayPort5Online INTEGER, ramosOptimaRelayArrayPort5GoOnline INTEGER, ramosOptimaRelayArrayPort5NormalState INTEGER, ramosOptimaRelayArrayPort5RelayCycleTime INTEGER, ramosOptimaRelayArrayPort5RelayAction INTEGER, ramosOptimaRelayArrayPort5ManualRelayCycleTime INTEGER, ramosOptimaRelayArrayPort5ManualRelayAction INTEGER, ramosOptimaRelayArrayPort5RelayDescOn DisplayString, ramosOptimaRelayArrayPort5RelayDescOff DisplayString, ramosOptimaRelayArrayPort5URL DisplayString, ramosOptimaRelayArrayPort5OpenURL INTEGER, ramosOptimaRelayArrayPort5ControlMode INTEGER } ramosOptimaRelayArrayPort5Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor RelayArray port." ::= { ramosOptimaRelayArrayPort5Entry 1 } ramosOptimaRelayArrayPort5Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor RelayArray" ::= { ramosOptimaRelayArrayPort5Entry 2 } ramosOptimaRelayArrayPort5Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaRelayArrayPort5Entry 4 } ramosOptimaRelayArrayPort5Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaRelayArrayPort5Entry 5 } ramosOptimaRelayArrayPort5GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaRelayArrayPort5Entry 6 } ramosOptimaRelayArrayPort5NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of RleayArray" ::= { ramosOptimaRelayArrayPort5Entry 7 } ramosOptimaRelayArrayPort5RelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaRelayArrayPort5Entry 18 } ramosOptimaRelayArrayPort5RelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaRelayArrayPort5Entry 21 } ramosOptimaRelayArrayPort5ManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaRelayArrayPort5Entry 24 } ramosOptimaRelayArrayPort5ManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaRelayArrayPort5Entry 25 } ramosOptimaRelayArrayPort5RelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaRelayArrayPort5Entry 26 } ramosOptimaRelayArrayPort5RelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaRelayArrayPort5Entry 27 } ramosOptimaRelayArrayPort5URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaRelayArrayPort5Entry 28 } ramosOptimaRelayArrayPort5OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaRelayArrayPort5Entry 29 } ramosOptimaRelayArrayPort5ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaRelayArrayPort5Entry 30 } ramosOptimaRelayArrayPort6 OBJECT IDENTIFIER ::= { ramosOptimaRelayArraySensor 6 } ramosOptimaRelayArrayPort6Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the RelayArray." ::= { ramosOptimaRelayArrayPort6 1 } ramosOptimaRelayArrayPort6Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaRelayArrayPort6Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaRelayArrayPort6 2 } ramosOptimaRelayArrayPort6Entry OBJECT-TYPE SYNTAX RamosOptimaRelayArrayPort6Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaRelayArrayPort6 Table" INDEX { ramosOptimaRelayArrayPort6Index } ::= { ramosOptimaRelayArrayPort6Table 1 } RamosOptimaRelayArrayPort6Entry ::= SEQUENCE { ramosOptimaRelayArrayPort6Index INTEGER, ramosOptimaRelayArrayPort6Description DisplayString, ramosOptimaRelayArrayPort6Status INTEGER, ramosOptimaRelayArrayPort6Online INTEGER, ramosOptimaRelayArrayPort6GoOnline INTEGER, ramosOptimaRelayArrayPort6NormalState INTEGER, ramosOptimaRelayArrayPort6RelayCycleTime INTEGER, ramosOptimaRelayArrayPort6RelayAction INTEGER, ramosOptimaRelayArrayPort6ManualRelayCycleTime INTEGER, ramosOptimaRelayArrayPort6ManualRelayAction INTEGER, ramosOptimaRelayArrayPort6RelayDescOn DisplayString, ramosOptimaRelayArrayPort6RelayDescOff DisplayString, ramosOptimaRelayArrayPort6URL DisplayString, ramosOptimaRelayArrayPort6OpenURL INTEGER, ramosOptimaRelayArrayPort6ControlMode INTEGER } ramosOptimaRelayArrayPort6Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor RelayArray port." ::= { ramosOptimaRelayArrayPort6Entry 1 } ramosOptimaRelayArrayPort6Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor RelayArray" ::= { ramosOptimaRelayArrayPort6Entry 2 } ramosOptimaRelayArrayPort6Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaRelayArrayPort6Entry 4 } ramosOptimaRelayArrayPort6Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaRelayArrayPort6Entry 5 } ramosOptimaRelayArrayPort6GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaRelayArrayPort6Entry 6 } ramosOptimaRelayArrayPort6NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of RleayArray" ::= { ramosOptimaRelayArrayPort6Entry 7 } ramosOptimaRelayArrayPort6RelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaRelayArrayPort6Entry 18 } ramosOptimaRelayArrayPort6RelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaRelayArrayPort6Entry 21 } ramosOptimaRelayArrayPort6ManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaRelayArrayPort6Entry 24 } ramosOptimaRelayArrayPort6ManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaRelayArrayPort6Entry 25 } ramosOptimaRelayArrayPort6RelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaRelayArrayPort6Entry 26 } ramosOptimaRelayArrayPort6RelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaRelayArrayPort6Entry 27 } ramosOptimaRelayArrayPort6URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaRelayArrayPort6Entry 28 } ramosOptimaRelayArrayPort6OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaRelayArrayPort6Entry 29 } ramosOptimaRelayArrayPort6ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaRelayArrayPort6Entry 30 } ramosOptimaRelayArrayPort7 OBJECT IDENTIFIER ::= { ramosOptimaRelayArraySensor 7 } ramosOptimaRelayArrayPort7Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the RelayArray." ::= { ramosOptimaRelayArrayPort7 1 } ramosOptimaRelayArrayPort7Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaRelayArrayPort7Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaRelayArrayPort7 2 } ramosOptimaRelayArrayPort7Entry OBJECT-TYPE SYNTAX RamosOptimaRelayArrayPort7Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaRelayArrayPort7 Table" INDEX { ramosOptimaRelayArrayPort7Index } ::= { ramosOptimaRelayArrayPort7Table 1 } RamosOptimaRelayArrayPort7Entry ::= SEQUENCE { ramosOptimaRelayArrayPort7Index INTEGER, ramosOptimaRelayArrayPort7Description DisplayString, ramosOptimaRelayArrayPort7Status INTEGER, ramosOptimaRelayArrayPort7Online INTEGER, ramosOptimaRelayArrayPort7GoOnline INTEGER, ramosOptimaRelayArrayPort7NormalState INTEGER, ramosOptimaRelayArrayPort7RelayCycleTime INTEGER, ramosOptimaRelayArrayPort7RelayAction INTEGER, ramosOptimaRelayArrayPort7ManualRelayCycleTime INTEGER, ramosOptimaRelayArrayPort7ManualRelayAction INTEGER, ramosOptimaRelayArrayPort7RelayDescOn DisplayString, ramosOptimaRelayArrayPort7RelayDescOff DisplayString, ramosOptimaRelayArrayPort7URL DisplayString, ramosOptimaRelayArrayPort7OpenURL INTEGER, ramosOptimaRelayArrayPort7ControlMode INTEGER } ramosOptimaRelayArrayPort7Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor RelayArray port." ::= { ramosOptimaRelayArrayPort7Entry 1 } ramosOptimaRelayArrayPort7Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor RelayArray" ::= { ramosOptimaRelayArrayPort7Entry 2 } ramosOptimaRelayArrayPort7Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaRelayArrayPort7Entry 4 } ramosOptimaRelayArrayPort7Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaRelayArrayPort7Entry 5 } ramosOptimaRelayArrayPort7GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaRelayArrayPort7Entry 6 } ramosOptimaRelayArrayPort7NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of RleayArray" ::= { ramosOptimaRelayArrayPort7Entry 7 } ramosOptimaRelayArrayPort7RelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaRelayArrayPort7Entry 18 } ramosOptimaRelayArrayPort7RelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaRelayArrayPort7Entry 21 } ramosOptimaRelayArrayPort7ManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaRelayArrayPort7Entry 24 } ramosOptimaRelayArrayPort7ManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaRelayArrayPort7Entry 25 } ramosOptimaRelayArrayPort7RelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaRelayArrayPort7Entry 26 } ramosOptimaRelayArrayPort7RelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaRelayArrayPort7Entry 27 } ramosOptimaRelayArrayPort7URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaRelayArrayPort7Entry 28 } ramosOptimaRelayArrayPort7OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaRelayArrayPort7Entry 29 } ramosOptimaRelayArrayPort7ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaRelayArrayPort7Entry 30 } ramosOptimaRelayArrayPort8 OBJECT IDENTIFIER ::= { ramosOptimaRelayArraySensor 8 } ramosOptimaRelayArrayPort8Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the RelayArray." ::= { ramosOptimaRelayArrayPort8 1 } ramosOptimaRelayArrayPort8Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaRelayArrayPort8Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaRelayArrayPort8 2 } ramosOptimaRelayArrayPort8Entry OBJECT-TYPE SYNTAX RamosOptimaRelayArrayPort8Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaRelayArrayPort8 Table" INDEX { ramosOptimaRelayArrayPort8Index } ::= { ramosOptimaRelayArrayPort8Table 1 } RamosOptimaRelayArrayPort8Entry ::= SEQUENCE { ramosOptimaRelayArrayPort8Index INTEGER, ramosOptimaRelayArrayPort8Description DisplayString, ramosOptimaRelayArrayPort8Status INTEGER, ramosOptimaRelayArrayPort8Online INTEGER, ramosOptimaRelayArrayPort8GoOnline INTEGER, ramosOptimaRelayArrayPort8NormalState INTEGER, ramosOptimaRelayArrayPort8RelayCycleTime INTEGER, ramosOptimaRelayArrayPort8RelayAction INTEGER, ramosOptimaRelayArrayPort8ManualRelayCycleTime INTEGER, ramosOptimaRelayArrayPort8ManualRelayAction INTEGER, ramosOptimaRelayArrayPort8RelayDescOn DisplayString, ramosOptimaRelayArrayPort8RelayDescOff DisplayString, ramosOptimaRelayArrayPort8URL DisplayString, ramosOptimaRelayArrayPort8OpenURL INTEGER, ramosOptimaRelayArrayPort8ControlMode INTEGER } ramosOptimaRelayArrayPort8Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor RelayArray port." ::= { ramosOptimaRelayArrayPort8Entry 1 } ramosOptimaRelayArrayPort8Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor RelayArray" ::= { ramosOptimaRelayArrayPort8Entry 2 } ramosOptimaRelayArrayPort8Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaRelayArrayPort8Entry 4 } ramosOptimaRelayArrayPort8Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaRelayArrayPort8Entry 5 } ramosOptimaRelayArrayPort8GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaRelayArrayPort8Entry 6 } ramosOptimaRelayArrayPort8NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of RleayArray" ::= { ramosOptimaRelayArrayPort8Entry 7 } ramosOptimaRelayArrayPort8RelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Cycle action." ::= { ramosOptimaRelayArrayPort8Entry 18 } ramosOptimaRelayArrayPort8RelayAction OBJECT-TYPE SYNTAX INTEGER { cycle(2), turn-on(3), turn-off(4) } ACCESS read-write STATUS mandatory DESCRIPTION "What the relay will do when the listened to port status turns to the specified active status." ::= { ramosOptimaRelayArrayPort8Entry 21 } ramosOptimaRelayArrayPort8ManualRelayCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Relay toggle period in seconds for Manual Cycle action." ::= { ramosOptimaRelayArrayPort8Entry 24 } ramosOptimaRelayArrayPort8ManualRelayAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { ramosOptimaRelayArrayPort8Entry 25 } ramosOptimaRelayArrayPort8RelayDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay On" ::= { ramosOptimaRelayArrayPort8Entry 26 } ramosOptimaRelayArrayPort8RelayDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of relay Off" ::= { ramosOptimaRelayArrayPort8Entry 27 } ramosOptimaRelayArrayPort8URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaRelayArrayPort8Entry 28 } ramosOptimaRelayArrayPort8OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaRelayArrayPort8Entry 29 } ramosOptimaRelayArrayPort8ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Relay Control Mode used for selecting the mode to control a relay." ::= { ramosOptimaRelayArrayPort8Entry 30 } ramosOptimaVirtualAnalogSensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 30 } ramosOptimaVirtualAnalogSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of VirtualAnalog Sensor port." ::= { ramosOptimaVirtualAnalogSensor 1 } ramosOptimaVirtualAnalogSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaVirtualAnalogSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every VirtualAnalog Sensor in the SensorArray. Each row in the table contains data for a different VirtualAnalog Sensor." ::= { ramosOptimaVirtualAnalogSensor 2 } ramosOptimaVirtualAnalogSensorEntry OBJECT-TYPE SYNTAX RamosOptimaVirtualAnalogSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaVirtualAnalogSensorEntry Table" INDEX { ramosOptimaVirtualAnalogSensorIndex } ::= { ramosOptimaVirtualAnalogSensorTable 1 } RamosOptimaVirtualAnalogSensorEntry ::= SEQUENCE { ramosOptimaVirtualAnalogSensorIndex INTEGER, ramosOptimaVirtualAnalogDescription DisplayString, ramosOptimaVirtualAnalogStatus INTEGER, ramosOptimaVirtualAnalogOnline INTEGER, ramosOptimaVirtualAnalogGoOnline INTEGER, ramosOptimaVirtualAnalogHighWarning INTEGER, ramosOptimaVirtualAnalogHighCritical INTEGER, ramosOptimaVirtualAnalogLowWarning INTEGER, ramosOptimaVirtualAnalogLowCritical INTEGER, ramosOptimaVirtualAnalogRearm INTEGER, ramosOptimaVirtualAnalogRaw INTEGER, ramosOptimaVirtualAnalogEmailTrapLimit INTEGER, ramosOptimaVirtualAnalogDelayError INTEGER, ramosOptimaVirtualAnalogDelayNormal INTEGER, ramosOptimaVirtualAnalogUnit DisplayString, ramosOptimaVirtualAnalogAcknowledgement INTEGER, ramosOptimaVirtualAnalogURL DisplayString, ramosOptimaVirtualAnalogOpenURL INTEGER, ramosOptimaVirtualAnalogContTimeHighCritical INTEGER, ramosOptimaVirtualAnalogContTimeHighWarning INTEGER, ramosOptimaVirtualAnalogContTimeNormal INTEGER, ramosOptimaVirtualAnalogContTimeLowWarning INTEGER, ramosOptimaVirtualAnalogContTimeLowCritical INTEGER, ramosOptimaVirtualAnalogContTimeSensorError INTEGER, ramosOptimaVirtualAnalogCalendar INTEGER, ramosOptimaVirtualAnalogValueFactor INTEGER } ramosOptimaVirtualAnalogSensorIndex OBJECT-TYPE SYNTAX INTEGER (0..67) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each VirtualAnalog sensor port." ::= { ramosOptimaVirtualAnalogSensorEntry 1 } ramosOptimaVirtualAnalogDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { ramosOptimaVirtualAnalogSensorEntry 2 } ramosOptimaVirtualAnalogStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaVirtualAnalogSensorEntry 4 } ramosOptimaVirtualAnalogOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaVirtualAnalogSensorEntry 5 } ramosOptimaVirtualAnalogGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaVirtualAnalogSensorEntry 6 } ramosOptimaVirtualAnalogHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative VirtualAnalog this sensor measures before it sends a warning" ::= { ramosOptimaVirtualAnalogSensorEntry 7 } ramosOptimaVirtualAnalogHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How high the relative VirtualAnalog this sensor measures before it becomes critical" ::= { ramosOptimaVirtualAnalogSensorEntry 8 } ramosOptimaVirtualAnalogLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative VirtualAnalog this sensor measures before it sends a warning" ::= { ramosOptimaVirtualAnalogSensorEntry 9 } ramosOptimaVirtualAnalogLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How low the relative VirtualAnalog this sensor measures before it becomes critical" ::= { ramosOptimaVirtualAnalogSensorEntry 10 } ramosOptimaVirtualAnalogRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The percent relative VirtualAnalog to rearm the status. For example if status goes from normal to warning, the VirtualAnalog must go down spAnalogueRearm below warning before the status goes to normal" ::= { ramosOptimaVirtualAnalogSensorEntry 11 } ramosOptimaVirtualAnalogRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { ramosOptimaVirtualAnalogSensorEntry 13 } ramosOptimaVirtualAnalogEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { ramosOptimaVirtualAnalogSensorEntry 17 } ramosOptimaVirtualAnalogDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { ramosOptimaVirtualAnalogSensorEntry 21 } ramosOptimaVirtualAnalogDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { ramosOptimaVirtualAnalogSensorEntry 22 } ramosOptimaVirtualAnalogUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Display unit in VirtualAnalog." ::= { ramosOptimaVirtualAnalogSensorEntry 27 } ramosOptimaVirtualAnalogAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledged sensor error and stop notification" ::= { ramosOptimaVirtualAnalogSensorEntry 41 } ramosOptimaVirtualAnalogURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaVirtualAnalogSensorEntry 43 } ramosOptimaVirtualAnalogOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaVirtualAnalogSensorEntry 44 } ramosOptimaVirtualAnalogContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaVirtualAnalogSensorEntry 45 } ramosOptimaVirtualAnalogContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaVirtualAnalogSensorEntry 46 } ramosOptimaVirtualAnalogContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaVirtualAnalogSensorEntry 47 } ramosOptimaVirtualAnalogContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaVirtualAnalogSensorEntry 48 } ramosOptimaVirtualAnalogContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaVirtualAnalogSensorEntry 49 } ramosOptimaVirtualAnalogContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaVirtualAnalogSensorEntry 50 } ramosOptimaVirtualAnalogCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaVirtualAnalogSensorEntry 51 } ramosOptimaVirtualAnalogValueFactor OBJECT-TYPE SYNTAX INTEGER { x1(1), x0-1(10), x0-01(100), x0-001(1000) } ACCESS read-write STATUS mandatory DESCRIPTION "To change the ratio of value." ::= { ramosOptimaVirtualAnalogSensorEntry 52 } ramosOptimaVirtualSwitchSensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 31 } ramosOptimaVirtualSwitchSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of VirtualSwitch Sensor port." ::= { ramosOptimaVirtualSwitchSensor 1 } ramosOptimaVirtualSwitchSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaVirtualSwitchSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every VirtualSwitch Sensor in the SensorArray. Each row in the table contains data for a different VirtualSwitch Sensor." ::= { ramosOptimaVirtualSwitchSensor 2 } ramosOptimaVirtualSwitchSensorEntry OBJECT-TYPE SYNTAX RamosOptimaVirtualSwitchSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaVirtualSwitchSensorEntry Table" INDEX { ramosOptimaVirtualSwitchSensorIndex } ::= { ramosOptimaVirtualSwitchSensorTable 1 } RamosOptimaVirtualSwitchSensorEntry ::= SEQUENCE { ramosOptimaVirtualSwitchSensorIndex INTEGER, ramosOptimaVirtualSwitchDescription DisplayString, ramosOptimaVirtualSwitchStatus INTEGER, ramosOptimaVirtualSwitchOnline INTEGER, ramosOptimaVirtualSwitchGoOnline INTEGER, ramosOptimaVirtualSwitchEmailTrapLimit INTEGER, ramosOptimaVirtualSwitchContTimeHighCritical INTEGER, ramosOptimaVirtualSwitchContTimeNormal INTEGER, ramosOptimaVirtualSwitchDescriptionCritical DisplayString, ramosOptimaVirtualSwitchDescriptionNormal DisplayString, ramosOptimaVirtualSwitchAcknowledgement INTEGER, ramosOptimaVirtualSwitchURL DisplayString, ramosOptimaVirtualSwitchOpenURL INTEGER, ramosOptimaVirtualSwitchCalendar INTEGER, ramosOptimaVirtualSwitchNormalState INTEGER } ramosOptimaVirtualSwitchSensorIndex OBJECT-TYPE SYNTAX INTEGER (0..67) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each VirtualSwitch sensor port." ::= { ramosOptimaVirtualSwitchSensorEntry 1 } ramosOptimaVirtualSwitchDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { ramosOptimaVirtualSwitchSensorEntry 2 } ramosOptimaVirtualSwitchStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaVirtualSwitchSensorEntry 4 } ramosOptimaVirtualSwitchOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaVirtualSwitchSensorEntry 5 } ramosOptimaVirtualSwitchGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaVirtualSwitchSensorEntry 6 } ramosOptimaVirtualSwitchEmailTrapLimit OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable email/trap limit feature" ::= { ramosOptimaVirtualSwitchSensorEntry 17 } ramosOptimaVirtualSwitchContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaVirtualSwitchSensorEntry 21 } ramosOptimaVirtualSwitchContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaVirtualSwitchSensorEntry 22 } ramosOptimaVirtualSwitchDescriptionCritical OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of status when the virsual switch is critical" ::= { ramosOptimaVirtualSwitchSensorEntry 26 } ramosOptimaVirtualSwitchDescriptionNormal OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of status when the virsual switch is normal" ::= { ramosOptimaVirtualSwitchSensorEntry 27 } ramosOptimaVirtualSwitchAcknowledgement OBJECT-TYPE SYNTAX INTEGER { ack(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledged sensor error and stop notification" ::= { ramosOptimaVirtualSwitchSensorEntry 41 } ramosOptimaVirtualSwitchURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaVirtualSwitchSensorEntry 43 } ramosOptimaVirtualSwitchOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaVirtualSwitchSensorEntry 44 } ramosOptimaVirtualSwitchCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaVirtualSwitchSensorEntry 45 } ramosOptimaVirtualSwitchNormalState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of a return of the virsual switch. If a return of the virsual switch is equal this normal state value, it is normal. Otherwise, it is critical." ::= { ramosOptimaVirtualSwitchSensorEntry 46 } ramosOptimaWattHoursSensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 32 } ramosOptimaWattHoursSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of WattHours Sensor port." ::= { ramosOptimaWattHoursSensor 1 } ramosOptimaWattHoursSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaWattHoursSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every WattHours Sensor in the SensorArray. Each row in the table contains data for a different WattHours Sensor." ::= { ramosOptimaWattHoursSensor 2 } ramosOptimaWattHoursSensorEntry OBJECT-TYPE SYNTAX RamosOptimaWattHoursSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaWattHoursSensorEntry Table" INDEX { ramosOptimaWattHoursSensorIndex } ::= { ramosOptimaWattHoursSensorTable 1 } RamosOptimaWattHoursSensorEntry ::= SEQUENCE { ramosOptimaWattHoursSensorIndex INTEGER, ramosOptimaWattHoursDescription DisplayString, ramosOptimaWattHoursPercent INTEGER, ramosOptimaWattHoursReset INTEGER } ramosOptimaWattHoursSensorIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each WattHours sensor port." ::= { ramosOptimaWattHoursSensorEntry 1 } ramosOptimaWattHoursDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { ramosOptimaWattHoursSensorEntry 2 } ramosOptimaWattHoursPercent OBJECT-TYPE SYNTAX INTEGER (-32768..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The relative WattHours percentage measured by this sensor" ::= { ramosOptimaWattHoursSensorEntry 3 } ramosOptimaWattHoursReset OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-write STATUS mandatory DESCRIPTION "The relative WattHours percentage measured by this sensor" ::= { ramosOptimaWattHoursSensorEntry 43 } ramosOptimaTemperatureArraySensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 33 } ramosOptimaTemperatureArrayPort1 OBJECT IDENTIFIER ::= { ramosOptimaTemperatureArraySensor 1 } ramosOptimaTemperatureArrayPort1Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the TemperatureArray." ::= { ramosOptimaTemperatureArrayPort1 1 } ramosOptimaTemperatureArrayPort1Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTemperatureArrayPort1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaTemperatureArrayPort1 2 } ramosOptimaTemperatureArrayPort1Entry OBJECT-TYPE SYNTAX RamosOptimaTemperatureArrayPort1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTemperatureArrayPort1 Table" INDEX { ramosOptimaTemperatureArrayPort1Index } ::= { ramosOptimaTemperatureArrayPort1Table 1 } RamosOptimaTemperatureArrayPort1Entry ::= SEQUENCE { ramosOptimaTemperatureArrayPort1Index INTEGER, ramosOptimaTemperatureArrayPort1Description DisplayString, ramosOptimaTemperatureArrayPort1Value INTEGER, ramosOptimaTemperatureArrayPort1Status INTEGER, ramosOptimaTemperatureArrayPort1Online INTEGER, ramosOptimaTemperatureArrayPort1GoOnline INTEGER, ramosOptimaTemperatureArrayPort1HighWarning INTEGER, ramosOptimaTemperatureArrayPort1HighCritical INTEGER, ramosOptimaTemperatureArrayPort1LowWarning INTEGER, ramosOptimaTemperatureArrayPort1LowCritical INTEGER, ramosOptimaTemperatureArrayPort1Rearm INTEGER, ramosOptimaTemperatureArrayPort1DegreeType INTEGER, ramosOptimaTemperatureArrayPort1DegreeRaw INTEGER, ramosOptimaTemperatureArrayPort1Offset INTEGER, ramosOptimaTemperatureArrayPort1URL DisplayString, ramosOptimaTemperatureArrayPort1OpenURL INTEGER, ramosOptimaTemperatureArrayPort1DatacollectType INTEGER, ramosOptimaTemperatureArrayPort1ContTimeHighCritical INTEGER, ramosOptimaTemperatureArrayPort1ContTimeHighWarning INTEGER, ramosOptimaTemperatureArrayPort1ContTimeNormal INTEGER, ramosOptimaTemperatureArrayPort1ContTimeLowWarning INTEGER, ramosOptimaTemperatureArrayPort1ContTimeLowCritical INTEGER, ramosOptimaTemperatureArrayPort1ContTimeSensorError INTEGER, ramosOptimaTemperatureArrayPort1Calendar INTEGER, ramosOptimaThermostatTemperatureArrayPort1Index INTEGER, ramosOptimaThermostatTemperatureArrayPort1Description DisplayString, ramosOptimaThermostatTemperatureArrayPort1Value INTEGER, ramosOptimaThermostatTemperatureArrayPort1Online INTEGER, ramosOptimaThermostatTemperatureArrayPort1GoOnline INTEGER, ramosOptimaThermostatTemperatureArrayPort1Mode INTEGER, ramosOptimaThermostatTemperatureArrayPort1RelayControlPort INTEGER, ramosOptimaThermostatTemperatureArrayPort1NormalAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort1HighLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort1HighLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort1LowLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort1LowLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort1NormalAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort1HighLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort1HighLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort1LowLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort1LowLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort1EnableTime DisplayString } ramosOptimaTemperatureArrayPort1Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor TemperatureArray port." ::= { ramosOptimaTemperatureArrayPort1Entry 1 } ramosOptimaTemperatureArrayPort1Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor TemperatureArray" ::= { ramosOptimaTemperatureArrayPort1Entry 2 } ramosOptimaTemperatureArrayPort1Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort1Entry 3 } ramosOptimaTemperatureArrayPort1Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTemperatureArrayPort1Entry 4 } ramosOptimaTemperatureArrayPort1Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort1Entry 5 } ramosOptimaTemperatureArrayPort1GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort1Entry 6 } ramosOptimaTemperatureArrayPort1HighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort1Entry 7 } ramosOptimaTemperatureArrayPort1HighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort1Entry 8 } ramosOptimaTemperatureArrayPort1LowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort1Entry 9 } ramosOptimaTemperatureArrayPort1LowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort1Entry 10 } ramosOptimaTemperatureArrayPort1Rearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTemperatureArrayPort1Entry 11 } ramosOptimaTemperatureArrayPort1DegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTemperatureArrayPort1Entry 12 } ramosOptimaTemperatureArrayPort1DegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTemperatureArrayPort1Entry 14 } ramosOptimaTemperatureArrayPort1Offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset reading" ::= { ramosOptimaTemperatureArrayPort1Entry 15 } ramosOptimaTemperatureArrayPort1URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTemperatureArrayPort1Entry 16 } ramosOptimaTemperatureArrayPort1OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTemperatureArrayPort1Entry 17 } ramosOptimaTemperatureArrayPort1DatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTemperatureArrayPort1Entry 18 } ramosOptimaTemperatureArrayPort1ContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort1Entry 19 } ramosOptimaTemperatureArrayPort1ContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort1Entry 20 } ramosOptimaTemperatureArrayPort1ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTemperatureArrayPort1Entry 21 } ramosOptimaTemperatureArrayPort1ContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort1Entry 22 } ramosOptimaTemperatureArrayPort1ContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort1Entry 23 } ramosOptimaTemperatureArrayPort1ContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTemperatureArrayPort1Entry 24 } ramosOptimaTemperatureArrayPort1Calendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTemperatureArrayPort1Entry 25 } ramosOptimaThermostatTemperatureArrayPort1Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTemperatureArrayPort1Entry 26 } ramosOptimaThermostatTemperatureArrayPort1Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTemperatureArrayPort1Entry 27 } ramosOptimaThermostatTemperatureArrayPort1Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort1Entry 28 } ramosOptimaThermostatTemperatureArrayPort1Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort1Entry 29 } ramosOptimaThermostatTemperatureArrayPort1GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort1Entry 30 } ramosOptimaThermostatTemperatureArrayPort1Mode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTemperatureArrayPort1Entry 31 } ramosOptimaThermostatTemperatureArrayPort1RelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTemperatureArrayPort1Entry 32 } ramosOptimaThermostatTemperatureArrayPort1NormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort1Entry 33 } ramosOptimaThermostatTemperatureArrayPort1HighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort1Entry 34 } ramosOptimaThermostatTemperatureArrayPort1HighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort1Entry 35 } ramosOptimaThermostatTemperatureArrayPort1LowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort1Entry 36 } ramosOptimaThermostatTemperatureArrayPort1LowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort1Entry 37 } ramosOptimaThermostatTemperatureArrayPort1NormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort1Entry 38 } ramosOptimaThermostatTemperatureArrayPort1HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort1Entry 39 } ramosOptimaThermostatTemperatureArrayPort1HighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort1Entry 40 } ramosOptimaThermostatTemperatureArrayPort1LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort1Entry 41 } ramosOptimaThermostatTemperatureArrayPort1LowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort1Entry 42 } ramosOptimaThermostatTemperatureArrayPort1EnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTemperatureArrayPort1Entry 43 } ramosOptimaTemperatureArrayPort2 OBJECT IDENTIFIER ::= { ramosOptimaTemperatureArraySensor 2 } ramosOptimaTemperatureArrayPort2Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the TemperatureArray." ::= { ramosOptimaTemperatureArrayPort2 1 } ramosOptimaTemperatureArrayPort2Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTemperatureArrayPort2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaTemperatureArrayPort2 2 } ramosOptimaTemperatureArrayPort2Entry OBJECT-TYPE SYNTAX RamosOptimaTemperatureArrayPort2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTemperatureArrayPort2 Table" INDEX { ramosOptimaTemperatureArrayPort2Index } ::= { ramosOptimaTemperatureArrayPort2Table 1 } RamosOptimaTemperatureArrayPort2Entry ::= SEQUENCE { ramosOptimaTemperatureArrayPort2Index INTEGER, ramosOptimaTemperatureArrayPort2Description DisplayString, ramosOptimaTemperatureArrayPort2Value INTEGER, ramosOptimaTemperatureArrayPort2Status INTEGER, ramosOptimaTemperatureArrayPort2Online INTEGER, ramosOptimaTemperatureArrayPort2GoOnline INTEGER, ramosOptimaTemperatureArrayPort2HighWarning INTEGER, ramosOptimaTemperatureArrayPort2HighCritical INTEGER, ramosOptimaTemperatureArrayPort2LowWarning INTEGER, ramosOptimaTemperatureArrayPort2LowCritical INTEGER, ramosOptimaTemperatureArrayPort2Rearm INTEGER, ramosOptimaTemperatureArrayPort2DegreeType INTEGER, ramosOptimaTemperatureArrayPort2DegreeRaw INTEGER, ramosOptimaTemperatureArrayPort2Offset INTEGER, ramosOptimaTemperatureArrayPort2URL DisplayString, ramosOptimaTemperatureArrayPort2OpenURL INTEGER, ramosOptimaTemperatureArrayPort2DatacollectType INTEGER, ramosOptimaTemperatureArrayPort2ContTimeHighCritical INTEGER, ramosOptimaTemperatureArrayPort2ContTimeHighWarning INTEGER, ramosOptimaTemperatureArrayPort2ContTimeNormal INTEGER, ramosOptimaTemperatureArrayPort2ContTimeLowWarning INTEGER, ramosOptimaTemperatureArrayPort2ContTimeLowCritical INTEGER, ramosOptimaTemperatureArrayPort2ContTimeSensorError INTEGER, ramosOptimaTemperatureArrayPort2Calendar INTEGER, ramosOptimaThermostatTemperatureArrayPort2Index INTEGER, ramosOptimaThermostatTemperatureArrayPort2Description DisplayString, ramosOptimaThermostatTemperatureArrayPort2Value INTEGER, ramosOptimaThermostatTemperatureArrayPort2Online INTEGER, ramosOptimaThermostatTemperatureArrayPort2GoOnline INTEGER, ramosOptimaThermostatTemperatureArrayPort2Mode INTEGER, ramosOptimaThermostatTemperatureArrayPort2RelayControlPort INTEGER, ramosOptimaThermostatTemperatureArrayPort2NormalAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort2HighLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort2HighLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort2LowLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort2LowLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort2NormalAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort2HighLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort2HighLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort2LowLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort2LowLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort2EnableTime DisplayString } ramosOptimaTemperatureArrayPort2Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor TemperatureArray port." ::= { ramosOptimaTemperatureArrayPort2Entry 1 } ramosOptimaTemperatureArrayPort2Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor TemperatureArray" ::= { ramosOptimaTemperatureArrayPort2Entry 2 } ramosOptimaTemperatureArrayPort2Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort2Entry 3 } ramosOptimaTemperatureArrayPort2Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTemperatureArrayPort2Entry 4 } ramosOptimaTemperatureArrayPort2Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort2Entry 5 } ramosOptimaTemperatureArrayPort2GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort2Entry 6 } ramosOptimaTemperatureArrayPort2HighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort2Entry 7 } ramosOptimaTemperatureArrayPort2HighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort2Entry 8 } ramosOptimaTemperatureArrayPort2LowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort2Entry 9 } ramosOptimaTemperatureArrayPort2LowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort2Entry 10 } ramosOptimaTemperatureArrayPort2Rearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTemperatureArrayPort2Entry 11 } ramosOptimaTemperatureArrayPort2DegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTemperatureArrayPort2Entry 12 } ramosOptimaTemperatureArrayPort2DegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTemperatureArrayPort2Entry 14 } ramosOptimaTemperatureArrayPort2Offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset reading" ::= { ramosOptimaTemperatureArrayPort2Entry 15 } ramosOptimaTemperatureArrayPort2URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTemperatureArrayPort2Entry 16 } ramosOptimaTemperatureArrayPort2OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTemperatureArrayPort2Entry 17 } ramosOptimaTemperatureArrayPort2DatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTemperatureArrayPort2Entry 18 } ramosOptimaTemperatureArrayPort2ContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort2Entry 19 } ramosOptimaTemperatureArrayPort2ContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort2Entry 20 } ramosOptimaTemperatureArrayPort2ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTemperatureArrayPort2Entry 21 } ramosOptimaTemperatureArrayPort2ContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort2Entry 22 } ramosOptimaTemperatureArrayPort2ContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort2Entry 23 } ramosOptimaTemperatureArrayPort2ContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTemperatureArrayPort2Entry 24 } ramosOptimaTemperatureArrayPort2Calendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTemperatureArrayPort2Entry 25 } ramosOptimaThermostatTemperatureArrayPort2Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTemperatureArrayPort2Entry 26 } ramosOptimaThermostatTemperatureArrayPort2Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTemperatureArrayPort2Entry 27 } ramosOptimaThermostatTemperatureArrayPort2Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort2Entry 28 } ramosOptimaThermostatTemperatureArrayPort2Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort2Entry 29 } ramosOptimaThermostatTemperatureArrayPort2GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort2Entry 30 } ramosOptimaThermostatTemperatureArrayPort2Mode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTemperatureArrayPort2Entry 31 } ramosOptimaThermostatTemperatureArrayPort2RelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTemperatureArrayPort2Entry 32 } ramosOptimaThermostatTemperatureArrayPort2NormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort2Entry 33 } ramosOptimaThermostatTemperatureArrayPort2HighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort2Entry 34 } ramosOptimaThermostatTemperatureArrayPort2HighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort2Entry 35 } ramosOptimaThermostatTemperatureArrayPort2LowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort2Entry 36 } ramosOptimaThermostatTemperatureArrayPort2LowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort2Entry 37 } ramosOptimaThermostatTemperatureArrayPort2NormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort2Entry 38 } ramosOptimaThermostatTemperatureArrayPort2HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort2Entry 39 } ramosOptimaThermostatTemperatureArrayPort2HighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort2Entry 40 } ramosOptimaThermostatTemperatureArrayPort2LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort2Entry 41 } ramosOptimaThermostatTemperatureArrayPort2LowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort2Entry 42 } ramosOptimaThermostatTemperatureArrayPort2EnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTemperatureArrayPort2Entry 43 } ramosOptimaTemperatureArrayPort3 OBJECT IDENTIFIER ::= { ramosOptimaTemperatureArraySensor 3 } ramosOptimaTemperatureArrayPort3Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the TemperatureArray." ::= { ramosOptimaTemperatureArrayPort3 1 } ramosOptimaTemperatureArrayPort3Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTemperatureArrayPort3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaTemperatureArrayPort3 2 } ramosOptimaTemperatureArrayPort3Entry OBJECT-TYPE SYNTAX RamosOptimaTemperatureArrayPort3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTemperatureArrayPort3 Table" INDEX { ramosOptimaTemperatureArrayPort3Index } ::= { ramosOptimaTemperatureArrayPort3Table 1 } RamosOptimaTemperatureArrayPort3Entry ::= SEQUENCE { ramosOptimaTemperatureArrayPort3Index INTEGER, ramosOptimaTemperatureArrayPort3Description DisplayString, ramosOptimaTemperatureArrayPort3Value INTEGER, ramosOptimaTemperatureArrayPort3Status INTEGER, ramosOptimaTemperatureArrayPort3Online INTEGER, ramosOptimaTemperatureArrayPort3GoOnline INTEGER, ramosOptimaTemperatureArrayPort3HighWarning INTEGER, ramosOptimaTemperatureArrayPort3HighCritical INTEGER, ramosOptimaTemperatureArrayPort3LowWarning INTEGER, ramosOptimaTemperatureArrayPort3LowCritical INTEGER, ramosOptimaTemperatureArrayPort3Rearm INTEGER, ramosOptimaTemperatureArrayPort3DegreeType INTEGER, ramosOptimaTemperatureArrayPort3DegreeRaw INTEGER, ramosOptimaTemperatureArrayPort3Offset INTEGER, ramosOptimaTemperatureArrayPort3URL DisplayString, ramosOptimaTemperatureArrayPort3OpenURL INTEGER, ramosOptimaTemperatureArrayPort3DatacollectType INTEGER, ramosOptimaTemperatureArrayPort3ContTimeHighCritical INTEGER, ramosOptimaTemperatureArrayPort3ContTimeHighWarning INTEGER, ramosOptimaTemperatureArrayPort3ContTimeNormal INTEGER, ramosOptimaTemperatureArrayPort3ContTimeLowWarning INTEGER, ramosOptimaTemperatureArrayPort3ContTimeLowCritical INTEGER, ramosOptimaTemperatureArrayPort3ContTimeSensorError INTEGER, ramosOptimaTemperatureArrayPort3Calendar INTEGER, ramosOptimaThermostatTemperatureArrayPort3Index INTEGER, ramosOptimaThermostatTemperatureArrayPort3Description DisplayString, ramosOptimaThermostatTemperatureArrayPort3Value INTEGER, ramosOptimaThermostatTemperatureArrayPort3Online INTEGER, ramosOptimaThermostatTemperatureArrayPort3GoOnline INTEGER, ramosOptimaThermostatTemperatureArrayPort3Mode INTEGER, ramosOptimaThermostatTemperatureArrayPort3RelayControlPort INTEGER, ramosOptimaThermostatTemperatureArrayPort3NormalAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort3HighLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort3HighLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort3LowLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort3LowLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort3NormalAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort3HighLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort3HighLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort3LowLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort3LowLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort3EnableTime DisplayString } ramosOptimaTemperatureArrayPort3Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor TemperatureArray port." ::= { ramosOptimaTemperatureArrayPort3Entry 1 } ramosOptimaTemperatureArrayPort3Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor TemperatureArray" ::= { ramosOptimaTemperatureArrayPort3Entry 2 } ramosOptimaTemperatureArrayPort3Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort3Entry 3 } ramosOptimaTemperatureArrayPort3Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTemperatureArrayPort3Entry 4 } ramosOptimaTemperatureArrayPort3Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort3Entry 5 } ramosOptimaTemperatureArrayPort3GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort3Entry 6 } ramosOptimaTemperatureArrayPort3HighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort3Entry 7 } ramosOptimaTemperatureArrayPort3HighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort3Entry 8 } ramosOptimaTemperatureArrayPort3LowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort3Entry 9 } ramosOptimaTemperatureArrayPort3LowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort3Entry 10 } ramosOptimaTemperatureArrayPort3Rearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTemperatureArrayPort3Entry 11 } ramosOptimaTemperatureArrayPort3DegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTemperatureArrayPort3Entry 12 } ramosOptimaTemperatureArrayPort3DegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTemperatureArrayPort3Entry 14 } ramosOptimaTemperatureArrayPort3Offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset reading" ::= { ramosOptimaTemperatureArrayPort3Entry 15 } ramosOptimaTemperatureArrayPort3URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTemperatureArrayPort3Entry 16 } ramosOptimaTemperatureArrayPort3OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTemperatureArrayPort3Entry 17 } ramosOptimaTemperatureArrayPort3DatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTemperatureArrayPort3Entry 18 } ramosOptimaTemperatureArrayPort3ContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort3Entry 19 } ramosOptimaTemperatureArrayPort3ContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort3Entry 20 } ramosOptimaTemperatureArrayPort3ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTemperatureArrayPort3Entry 21 } ramosOptimaTemperatureArrayPort3ContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort3Entry 22 } ramosOptimaTemperatureArrayPort3ContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort3Entry 23 } ramosOptimaTemperatureArrayPort3ContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTemperatureArrayPort3Entry 24 } ramosOptimaTemperatureArrayPort3Calendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTemperatureArrayPort3Entry 25 } ramosOptimaThermostatTemperatureArrayPort3Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTemperatureArrayPort3Entry 26 } ramosOptimaThermostatTemperatureArrayPort3Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTemperatureArrayPort3Entry 27 } ramosOptimaThermostatTemperatureArrayPort3Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort3Entry 28 } ramosOptimaThermostatTemperatureArrayPort3Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort3Entry 29 } ramosOptimaThermostatTemperatureArrayPort3GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort3Entry 30 } ramosOptimaThermostatTemperatureArrayPort3Mode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTemperatureArrayPort3Entry 31 } ramosOptimaThermostatTemperatureArrayPort3RelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTemperatureArrayPort3Entry 32 } ramosOptimaThermostatTemperatureArrayPort3NormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort3Entry 33 } ramosOptimaThermostatTemperatureArrayPort3HighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort3Entry 34 } ramosOptimaThermostatTemperatureArrayPort3HighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort3Entry 35 } ramosOptimaThermostatTemperatureArrayPort3LowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort3Entry 36 } ramosOptimaThermostatTemperatureArrayPort3LowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort3Entry 37 } ramosOptimaThermostatTemperatureArrayPort3NormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort3Entry 38 } ramosOptimaThermostatTemperatureArrayPort3HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort3Entry 39 } ramosOptimaThermostatTemperatureArrayPort3HighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort3Entry 40 } ramosOptimaThermostatTemperatureArrayPort3LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort3Entry 41 } ramosOptimaThermostatTemperatureArrayPort3LowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort3Entry 42 } ramosOptimaThermostatTemperatureArrayPort3EnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTemperatureArrayPort3Entry 43 } ramosOptimaTemperatureArrayPort4 OBJECT IDENTIFIER ::= { ramosOptimaTemperatureArraySensor 4 } ramosOptimaTemperatureArrayPort4Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the TemperatureArray." ::= { ramosOptimaTemperatureArrayPort4 1 } ramosOptimaTemperatureArrayPort4Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTemperatureArrayPort4Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaTemperatureArrayPort4 2 } ramosOptimaTemperatureArrayPort4Entry OBJECT-TYPE SYNTAX RamosOptimaTemperatureArrayPort4Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTemperatureArrayPort4 Table" INDEX { ramosOptimaTemperatureArrayPort4Index } ::= { ramosOptimaTemperatureArrayPort4Table 1 } RamosOptimaTemperatureArrayPort4Entry ::= SEQUENCE { ramosOptimaTemperatureArrayPort4Index INTEGER, ramosOptimaTemperatureArrayPort4Description DisplayString, ramosOptimaTemperatureArrayPort4Value INTEGER, ramosOptimaTemperatureArrayPort4Status INTEGER, ramosOptimaTemperatureArrayPort4Online INTEGER, ramosOptimaTemperatureArrayPort4GoOnline INTEGER, ramosOptimaTemperatureArrayPort4HighWarning INTEGER, ramosOptimaTemperatureArrayPort4HighCritical INTEGER, ramosOptimaTemperatureArrayPort4LowWarning INTEGER, ramosOptimaTemperatureArrayPort4LowCritical INTEGER, ramosOptimaTemperatureArrayPort4Rearm INTEGER, ramosOptimaTemperatureArrayPort4DegreeType INTEGER, ramosOptimaTemperatureArrayPort4DegreeRaw INTEGER, ramosOptimaTemperatureArrayPort4Offset INTEGER, ramosOptimaTemperatureArrayPort4URL DisplayString, ramosOptimaTemperatureArrayPort4OpenURL INTEGER, ramosOptimaTemperatureArrayPort4DatacollectType INTEGER, ramosOptimaTemperatureArrayPort4ContTimeHighCritical INTEGER, ramosOptimaTemperatureArrayPort4ContTimeHighWarning INTEGER, ramosOptimaTemperatureArrayPort4ContTimeNormal INTEGER, ramosOptimaTemperatureArrayPort4ContTimeLowWarning INTEGER, ramosOptimaTemperatureArrayPort4ContTimeLowCritical INTEGER, ramosOptimaTemperatureArrayPort4ContTimeSensorError INTEGER, ramosOptimaTemperatureArrayPort4Calendar INTEGER, ramosOptimaThermostatTemperatureArrayPort4Index INTEGER, ramosOptimaThermostatTemperatureArrayPort4Description DisplayString, ramosOptimaThermostatTemperatureArrayPort4Value INTEGER, ramosOptimaThermostatTemperatureArrayPort4Online INTEGER, ramosOptimaThermostatTemperatureArrayPort4GoOnline INTEGER, ramosOptimaThermostatTemperatureArrayPort4Mode INTEGER, ramosOptimaThermostatTemperatureArrayPort4RelayControlPort INTEGER, ramosOptimaThermostatTemperatureArrayPort4NormalAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort4HighLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort4HighLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort4LowLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort4LowLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort4NormalAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort4HighLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort4HighLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort4LowLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort4LowLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort4EnableTime DisplayString } ramosOptimaTemperatureArrayPort4Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor TemperatureArray port." ::= { ramosOptimaTemperatureArrayPort4Entry 1 } ramosOptimaTemperatureArrayPort4Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor TemperatureArray" ::= { ramosOptimaTemperatureArrayPort4Entry 2 } ramosOptimaTemperatureArrayPort4Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort4Entry 3 } ramosOptimaTemperatureArrayPort4Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTemperatureArrayPort4Entry 4 } ramosOptimaTemperatureArrayPort4Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort4Entry 5 } ramosOptimaTemperatureArrayPort4GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort4Entry 6 } ramosOptimaTemperatureArrayPort4HighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort4Entry 7 } ramosOptimaTemperatureArrayPort4HighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort4Entry 8 } ramosOptimaTemperatureArrayPort4LowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort4Entry 9 } ramosOptimaTemperatureArrayPort4LowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort4Entry 10 } ramosOptimaTemperatureArrayPort4Rearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTemperatureArrayPort4Entry 11 } ramosOptimaTemperatureArrayPort4DegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTemperatureArrayPort4Entry 12 } ramosOptimaTemperatureArrayPort4DegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTemperatureArrayPort4Entry 14 } ramosOptimaTemperatureArrayPort4Offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset reading" ::= { ramosOptimaTemperatureArrayPort4Entry 15 } ramosOptimaTemperatureArrayPort4URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTemperatureArrayPort4Entry 16 } ramosOptimaTemperatureArrayPort4OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTemperatureArrayPort4Entry 17 } ramosOptimaTemperatureArrayPort4DatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTemperatureArrayPort4Entry 18 } ramosOptimaTemperatureArrayPort4ContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort4Entry 19 } ramosOptimaTemperatureArrayPort4ContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort4Entry 20 } ramosOptimaTemperatureArrayPort4ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTemperatureArrayPort4Entry 21 } ramosOptimaTemperatureArrayPort4ContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort4Entry 22 } ramosOptimaTemperatureArrayPort4ContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort4Entry 23 } ramosOptimaTemperatureArrayPort4ContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTemperatureArrayPort4Entry 24 } ramosOptimaTemperatureArrayPort4Calendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTemperatureArrayPort4Entry 25 } ramosOptimaThermostatTemperatureArrayPort4Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTemperatureArrayPort4Entry 26 } ramosOptimaThermostatTemperatureArrayPort4Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTemperatureArrayPort4Entry 27 } ramosOptimaThermostatTemperatureArrayPort4Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort4Entry 28 } ramosOptimaThermostatTemperatureArrayPort4Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort4Entry 29 } ramosOptimaThermostatTemperatureArrayPort4GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort4Entry 30 } ramosOptimaThermostatTemperatureArrayPort4Mode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTemperatureArrayPort4Entry 31 } ramosOptimaThermostatTemperatureArrayPort4RelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTemperatureArrayPort4Entry 32 } ramosOptimaThermostatTemperatureArrayPort4NormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort4Entry 33 } ramosOptimaThermostatTemperatureArrayPort4HighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort4Entry 34 } ramosOptimaThermostatTemperatureArrayPort4HighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort4Entry 35 } ramosOptimaThermostatTemperatureArrayPort4LowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort4Entry 36 } ramosOptimaThermostatTemperatureArrayPort4LowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort4Entry 37 } ramosOptimaThermostatTemperatureArrayPort4NormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort4Entry 38 } ramosOptimaThermostatTemperatureArrayPort4HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort4Entry 39 } ramosOptimaThermostatTemperatureArrayPort4HighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort4Entry 40 } ramosOptimaThermostatTemperatureArrayPort4LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort4Entry 41 } ramosOptimaThermostatTemperatureArrayPort4LowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort4Entry 42 } ramosOptimaThermostatTemperatureArrayPort4EnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTemperatureArrayPort4Entry 43 } ramosOptimaTemperatureArrayPort5 OBJECT IDENTIFIER ::= { ramosOptimaTemperatureArraySensor 5 } ramosOptimaTemperatureArrayPort5Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the TemperatureArray." ::= { ramosOptimaTemperatureArrayPort5 1 } ramosOptimaTemperatureArrayPort5Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTemperatureArrayPort5Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaTemperatureArrayPort5 2 } ramosOptimaTemperatureArrayPort5Entry OBJECT-TYPE SYNTAX RamosOptimaTemperatureArrayPort5Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTemperatureArrayPort5 Table" INDEX { ramosOptimaTemperatureArrayPort5Index } ::= { ramosOptimaTemperatureArrayPort5Table 1 } RamosOptimaTemperatureArrayPort5Entry ::= SEQUENCE { ramosOptimaTemperatureArrayPort5Index INTEGER, ramosOptimaTemperatureArrayPort5Description DisplayString, ramosOptimaTemperatureArrayPort5Value INTEGER, ramosOptimaTemperatureArrayPort5Status INTEGER, ramosOptimaTemperatureArrayPort5Online INTEGER, ramosOptimaTemperatureArrayPort5GoOnline INTEGER, ramosOptimaTemperatureArrayPort5HighWarning INTEGER, ramosOptimaTemperatureArrayPort5HighCritical INTEGER, ramosOptimaTemperatureArrayPort5LowWarning INTEGER, ramosOptimaTemperatureArrayPort5LowCritical INTEGER, ramosOptimaTemperatureArrayPort5Rearm INTEGER, ramosOptimaTemperatureArrayPort5DegreeType INTEGER, ramosOptimaTemperatureArrayPort5DegreeRaw INTEGER, ramosOptimaTemperatureArrayPort5Offset INTEGER, ramosOptimaTemperatureArrayPort5URL DisplayString, ramosOptimaTemperatureArrayPort5OpenURL INTEGER, ramosOptimaTemperatureArrayPort5DatacollectType INTEGER, ramosOptimaTemperatureArrayPort5ContTimeHighCritical INTEGER, ramosOptimaTemperatureArrayPort5ContTimeHighWarning INTEGER, ramosOptimaTemperatureArrayPort5ContTimeNormal INTEGER, ramosOptimaTemperatureArrayPort5ContTimeLowWarning INTEGER, ramosOptimaTemperatureArrayPort5ContTimeLowCritical INTEGER, ramosOptimaTemperatureArrayPort5ContTimeSensorError INTEGER, ramosOptimaTemperatureArrayPort5Calendar INTEGER, ramosOptimaThermostatTemperatureArrayPort5Index INTEGER, ramosOptimaThermostatTemperatureArrayPort5Description DisplayString, ramosOptimaThermostatTemperatureArrayPort5Value INTEGER, ramosOptimaThermostatTemperatureArrayPort5Online INTEGER, ramosOptimaThermostatTemperatureArrayPort5GoOnline INTEGER, ramosOptimaThermostatTemperatureArrayPort5Mode INTEGER, ramosOptimaThermostatTemperatureArrayPort5RelayControlPort INTEGER, ramosOptimaThermostatTemperatureArrayPort5NormalAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort5HighLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort5HighLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort5LowLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort5LowLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort5NormalAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort5HighLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort5HighLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort5LowLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort5LowLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort5EnableTime DisplayString } ramosOptimaTemperatureArrayPort5Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor TemperatureArray port." ::= { ramosOptimaTemperatureArrayPort5Entry 1 } ramosOptimaTemperatureArrayPort5Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor TemperatureArray" ::= { ramosOptimaTemperatureArrayPort5Entry 2 } ramosOptimaTemperatureArrayPort5Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort5Entry 3 } ramosOptimaTemperatureArrayPort5Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTemperatureArrayPort5Entry 4 } ramosOptimaTemperatureArrayPort5Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort5Entry 5 } ramosOptimaTemperatureArrayPort5GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort5Entry 6 } ramosOptimaTemperatureArrayPort5HighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort5Entry 7 } ramosOptimaTemperatureArrayPort5HighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort5Entry 8 } ramosOptimaTemperatureArrayPort5LowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort5Entry 9 } ramosOptimaTemperatureArrayPort5LowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort5Entry 10 } ramosOptimaTemperatureArrayPort5Rearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTemperatureArrayPort5Entry 11 } ramosOptimaTemperatureArrayPort5DegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTemperatureArrayPort5Entry 12 } ramosOptimaTemperatureArrayPort5DegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTemperatureArrayPort5Entry 14 } ramosOptimaTemperatureArrayPort5Offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset reading" ::= { ramosOptimaTemperatureArrayPort5Entry 15 } ramosOptimaTemperatureArrayPort5URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTemperatureArrayPort5Entry 16 } ramosOptimaTemperatureArrayPort5OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTemperatureArrayPort5Entry 17 } ramosOptimaTemperatureArrayPort5DatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTemperatureArrayPort5Entry 18 } ramosOptimaTemperatureArrayPort5ContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort5Entry 19 } ramosOptimaTemperatureArrayPort5ContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort5Entry 20 } ramosOptimaTemperatureArrayPort5ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTemperatureArrayPort5Entry 21 } ramosOptimaTemperatureArrayPort5ContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort5Entry 22 } ramosOptimaTemperatureArrayPort5ContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort5Entry 23 } ramosOptimaTemperatureArrayPort5ContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTemperatureArrayPort5Entry 24 } ramosOptimaTemperatureArrayPort5Calendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTemperatureArrayPort5Entry 25 } ramosOptimaThermostatTemperatureArrayPort5Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTemperatureArrayPort5Entry 26 } ramosOptimaThermostatTemperatureArrayPort5Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTemperatureArrayPort5Entry 27 } ramosOptimaThermostatTemperatureArrayPort5Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort5Entry 28 } ramosOptimaThermostatTemperatureArrayPort5Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort5Entry 29 } ramosOptimaThermostatTemperatureArrayPort5GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort5Entry 30 } ramosOptimaThermostatTemperatureArrayPort5Mode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTemperatureArrayPort5Entry 31 } ramosOptimaThermostatTemperatureArrayPort5RelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTemperatureArrayPort5Entry 32 } ramosOptimaThermostatTemperatureArrayPort5NormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort5Entry 33 } ramosOptimaThermostatTemperatureArrayPort5HighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort5Entry 34 } ramosOptimaThermostatTemperatureArrayPort5HighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort5Entry 35 } ramosOptimaThermostatTemperatureArrayPort5LowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort5Entry 36 } ramosOptimaThermostatTemperatureArrayPort5LowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort5Entry 37 } ramosOptimaThermostatTemperatureArrayPort5NormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort5Entry 38 } ramosOptimaThermostatTemperatureArrayPort5HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort5Entry 39 } ramosOptimaThermostatTemperatureArrayPort5HighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort5Entry 40 } ramosOptimaThermostatTemperatureArrayPort5LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort5Entry 41 } ramosOptimaThermostatTemperatureArrayPort5LowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort5Entry 42 } ramosOptimaThermostatTemperatureArrayPort5EnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTemperatureArrayPort5Entry 43 } ramosOptimaTemperatureArrayPort6 OBJECT IDENTIFIER ::= { ramosOptimaTemperatureArraySensor 6 } ramosOptimaTemperatureArrayPort6Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the TemperatureArray." ::= { ramosOptimaTemperatureArrayPort6 1 } ramosOptimaTemperatureArrayPort6Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTemperatureArrayPort6Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaTemperatureArrayPort6 2 } ramosOptimaTemperatureArrayPort6Entry OBJECT-TYPE SYNTAX RamosOptimaTemperatureArrayPort6Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTemperatureArrayPort6 Table" INDEX { ramosOptimaTemperatureArrayPort6Index } ::= { ramosOptimaTemperatureArrayPort6Table 1 } RamosOptimaTemperatureArrayPort6Entry ::= SEQUENCE { ramosOptimaTemperatureArrayPort6Index INTEGER, ramosOptimaTemperatureArrayPort6Description DisplayString, ramosOptimaTemperatureArrayPort6Value INTEGER, ramosOptimaTemperatureArrayPort6Status INTEGER, ramosOptimaTemperatureArrayPort6Online INTEGER, ramosOptimaTemperatureArrayPort6GoOnline INTEGER, ramosOptimaTemperatureArrayPort6HighWarning INTEGER, ramosOptimaTemperatureArrayPort6HighCritical INTEGER, ramosOptimaTemperatureArrayPort6LowWarning INTEGER, ramosOptimaTemperatureArrayPort6LowCritical INTEGER, ramosOptimaTemperatureArrayPort6Rearm INTEGER, ramosOptimaTemperatureArrayPort6DegreeType INTEGER, ramosOptimaTemperatureArrayPort6DegreeRaw INTEGER, ramosOptimaTemperatureArrayPort6Offset INTEGER, ramosOptimaTemperatureArrayPort6URL DisplayString, ramosOptimaTemperatureArrayPort6OpenURL INTEGER, ramosOptimaTemperatureArrayPort6DatacollectType INTEGER, ramosOptimaTemperatureArrayPort6ContTimeHighCritical INTEGER, ramosOptimaTemperatureArrayPort6ContTimeHighWarning INTEGER, ramosOptimaTemperatureArrayPort6ContTimeNormal INTEGER, ramosOptimaTemperatureArrayPort6ContTimeLowWarning INTEGER, ramosOptimaTemperatureArrayPort6ContTimeLowCritical INTEGER, ramosOptimaTemperatureArrayPort6ContTimeSensorError INTEGER, ramosOptimaTemperatureArrayPort6Calendar INTEGER, ramosOptimaThermostatTemperatureArrayPort6Index INTEGER, ramosOptimaThermostatTemperatureArrayPort6Description DisplayString, ramosOptimaThermostatTemperatureArrayPort6Value INTEGER, ramosOptimaThermostatTemperatureArrayPort6Online INTEGER, ramosOptimaThermostatTemperatureArrayPort6GoOnline INTEGER, ramosOptimaThermostatTemperatureArrayPort6Mode INTEGER, ramosOptimaThermostatTemperatureArrayPort6RelayControlPort INTEGER, ramosOptimaThermostatTemperatureArrayPort6NormalAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort6HighLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort6HighLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort6LowLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort6LowLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort6NormalAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort6HighLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort6HighLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort6LowLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort6LowLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort6EnableTime DisplayString } ramosOptimaTemperatureArrayPort6Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor TemperatureArray port." ::= { ramosOptimaTemperatureArrayPort6Entry 1 } ramosOptimaTemperatureArrayPort6Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor TemperatureArray" ::= { ramosOptimaTemperatureArrayPort6Entry 2 } ramosOptimaTemperatureArrayPort6Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort6Entry 3 } ramosOptimaTemperatureArrayPort6Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTemperatureArrayPort6Entry 4 } ramosOptimaTemperatureArrayPort6Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort6Entry 5 } ramosOptimaTemperatureArrayPort6GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort6Entry 6 } ramosOptimaTemperatureArrayPort6HighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort6Entry 7 } ramosOptimaTemperatureArrayPort6HighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort6Entry 8 } ramosOptimaTemperatureArrayPort6LowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort6Entry 9 } ramosOptimaTemperatureArrayPort6LowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort6Entry 10 } ramosOptimaTemperatureArrayPort6Rearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTemperatureArrayPort6Entry 11 } ramosOptimaTemperatureArrayPort6DegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTemperatureArrayPort6Entry 12 } ramosOptimaTemperatureArrayPort6DegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTemperatureArrayPort6Entry 14 } ramosOptimaTemperatureArrayPort6Offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset reading" ::= { ramosOptimaTemperatureArrayPort6Entry 15 } ramosOptimaTemperatureArrayPort6URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTemperatureArrayPort6Entry 16 } ramosOptimaTemperatureArrayPort6OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTemperatureArrayPort6Entry 17 } ramosOptimaTemperatureArrayPort6DatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTemperatureArrayPort6Entry 18 } ramosOptimaTemperatureArrayPort6ContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort6Entry 19 } ramosOptimaTemperatureArrayPort6ContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort6Entry 20 } ramosOptimaTemperatureArrayPort6ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTemperatureArrayPort6Entry 21 } ramosOptimaTemperatureArrayPort6ContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort6Entry 22 } ramosOptimaTemperatureArrayPort6ContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort6Entry 23 } ramosOptimaTemperatureArrayPort6ContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTemperatureArrayPort6Entry 24 } ramosOptimaTemperatureArrayPort6Calendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTemperatureArrayPort6Entry 25 } ramosOptimaThermostatTemperatureArrayPort6Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTemperatureArrayPort6Entry 26 } ramosOptimaThermostatTemperatureArrayPort6Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTemperatureArrayPort6Entry 27 } ramosOptimaThermostatTemperatureArrayPort6Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort6Entry 28 } ramosOptimaThermostatTemperatureArrayPort6Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort6Entry 29 } ramosOptimaThermostatTemperatureArrayPort6GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort6Entry 30 } ramosOptimaThermostatTemperatureArrayPort6Mode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTemperatureArrayPort6Entry 31 } ramosOptimaThermostatTemperatureArrayPort6RelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTemperatureArrayPort6Entry 32 } ramosOptimaThermostatTemperatureArrayPort6NormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort6Entry 33 } ramosOptimaThermostatTemperatureArrayPort6HighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort6Entry 34 } ramosOptimaThermostatTemperatureArrayPort6HighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort6Entry 35 } ramosOptimaThermostatTemperatureArrayPort6LowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort6Entry 36 } ramosOptimaThermostatTemperatureArrayPort6LowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort6Entry 37 } ramosOptimaThermostatTemperatureArrayPort6NormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort6Entry 38 } ramosOptimaThermostatTemperatureArrayPort6HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort6Entry 39 } ramosOptimaThermostatTemperatureArrayPort6HighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort6Entry 40 } ramosOptimaThermostatTemperatureArrayPort6LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort6Entry 41 } ramosOptimaThermostatTemperatureArrayPort6LowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort6Entry 42 } ramosOptimaThermostatTemperatureArrayPort6EnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTemperatureArrayPort6Entry 43 } ramosOptimaTemperatureArrayPort7 OBJECT IDENTIFIER ::= { ramosOptimaTemperatureArraySensor 7 } ramosOptimaTemperatureArrayPort7Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the TemperatureArray." ::= { ramosOptimaTemperatureArrayPort7 1 } ramosOptimaTemperatureArrayPort7Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTemperatureArrayPort7Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaTemperatureArrayPort7 2 } ramosOptimaTemperatureArrayPort7Entry OBJECT-TYPE SYNTAX RamosOptimaTemperatureArrayPort7Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTemperatureArrayPort7 Table" INDEX { ramosOptimaTemperatureArrayPort7Index } ::= { ramosOptimaTemperatureArrayPort7Table 1 } RamosOptimaTemperatureArrayPort7Entry ::= SEQUENCE { ramosOptimaTemperatureArrayPort7Index INTEGER, ramosOptimaTemperatureArrayPort7Description DisplayString, ramosOptimaTemperatureArrayPort7Value INTEGER, ramosOptimaTemperatureArrayPort7Status INTEGER, ramosOptimaTemperatureArrayPort7Online INTEGER, ramosOptimaTemperatureArrayPort7GoOnline INTEGER, ramosOptimaTemperatureArrayPort7HighWarning INTEGER, ramosOptimaTemperatureArrayPort7HighCritical INTEGER, ramosOptimaTemperatureArrayPort7LowWarning INTEGER, ramosOptimaTemperatureArrayPort7LowCritical INTEGER, ramosOptimaTemperatureArrayPort7Rearm INTEGER, ramosOptimaTemperatureArrayPort7DegreeType INTEGER, ramosOptimaTemperatureArrayPort7DegreeRaw INTEGER, ramosOptimaTemperatureArrayPort7Offset INTEGER, ramosOptimaTemperatureArrayPort7URL DisplayString, ramosOptimaTemperatureArrayPort7OpenURL INTEGER, ramosOptimaTemperatureArrayPort7DatacollectType INTEGER, ramosOptimaTemperatureArrayPort7ContTimeHighCritical INTEGER, ramosOptimaTemperatureArrayPort7ContTimeHighWarning INTEGER, ramosOptimaTemperatureArrayPort7ContTimeNormal INTEGER, ramosOptimaTemperatureArrayPort7ContTimeLowWarning INTEGER, ramosOptimaTemperatureArrayPort7ContTimeLowCritical INTEGER, ramosOptimaTemperatureArrayPort7ContTimeSensorError INTEGER, ramosOptimaTemperatureArrayPort7Calendar INTEGER, ramosOptimaThermostatTemperatureArrayPort7Index INTEGER, ramosOptimaThermostatTemperatureArrayPort7Description DisplayString, ramosOptimaThermostatTemperatureArrayPort7Value INTEGER, ramosOptimaThermostatTemperatureArrayPort7Online INTEGER, ramosOptimaThermostatTemperatureArrayPort7GoOnline INTEGER, ramosOptimaThermostatTemperatureArrayPort7Mode INTEGER, ramosOptimaThermostatTemperatureArrayPort7RelayControlPort INTEGER, ramosOptimaThermostatTemperatureArrayPort7NormalAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort7HighLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort7HighLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort7LowLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort7LowLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort7NormalAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort7HighLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort7HighLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort7LowLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort7LowLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort7EnableTime DisplayString } ramosOptimaTemperatureArrayPort7Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor TemperatureArray port." ::= { ramosOptimaTemperatureArrayPort7Entry 1 } ramosOptimaTemperatureArrayPort7Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor TemperatureArray" ::= { ramosOptimaTemperatureArrayPort7Entry 2 } ramosOptimaTemperatureArrayPort7Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort7Entry 3 } ramosOptimaTemperatureArrayPort7Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTemperatureArrayPort7Entry 4 } ramosOptimaTemperatureArrayPort7Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort7Entry 5 } ramosOptimaTemperatureArrayPort7GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort7Entry 6 } ramosOptimaTemperatureArrayPort7HighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort7Entry 7 } ramosOptimaTemperatureArrayPort7HighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort7Entry 8 } ramosOptimaTemperatureArrayPort7LowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort7Entry 9 } ramosOptimaTemperatureArrayPort7LowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort7Entry 10 } ramosOptimaTemperatureArrayPort7Rearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTemperatureArrayPort7Entry 11 } ramosOptimaTemperatureArrayPort7DegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTemperatureArrayPort7Entry 12 } ramosOptimaTemperatureArrayPort7DegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTemperatureArrayPort7Entry 14 } ramosOptimaTemperatureArrayPort7Offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset reading" ::= { ramosOptimaTemperatureArrayPort7Entry 15 } ramosOptimaTemperatureArrayPort7URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTemperatureArrayPort7Entry 16 } ramosOptimaTemperatureArrayPort7OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTemperatureArrayPort7Entry 17 } ramosOptimaTemperatureArrayPort7DatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTemperatureArrayPort7Entry 18 } ramosOptimaTemperatureArrayPort7ContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort7Entry 19 } ramosOptimaTemperatureArrayPort7ContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort7Entry 20 } ramosOptimaTemperatureArrayPort7ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTemperatureArrayPort7Entry 21 } ramosOptimaTemperatureArrayPort7ContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort7Entry 22 } ramosOptimaTemperatureArrayPort7ContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort7Entry 23 } ramosOptimaTemperatureArrayPort7ContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTemperatureArrayPort7Entry 24 } ramosOptimaTemperatureArrayPort7Calendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTemperatureArrayPort7Entry 25 } ramosOptimaThermostatTemperatureArrayPort7Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTemperatureArrayPort7Entry 26 } ramosOptimaThermostatTemperatureArrayPort7Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTemperatureArrayPort7Entry 27 } ramosOptimaThermostatTemperatureArrayPort7Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort7Entry 28 } ramosOptimaThermostatTemperatureArrayPort7Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort7Entry 29 } ramosOptimaThermostatTemperatureArrayPort7GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort7Entry 30 } ramosOptimaThermostatTemperatureArrayPort7Mode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTemperatureArrayPort7Entry 31 } ramosOptimaThermostatTemperatureArrayPort7RelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTemperatureArrayPort7Entry 32 } ramosOptimaThermostatTemperatureArrayPort7NormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort7Entry 33 } ramosOptimaThermostatTemperatureArrayPort7HighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort7Entry 34 } ramosOptimaThermostatTemperatureArrayPort7HighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort7Entry 35 } ramosOptimaThermostatTemperatureArrayPort7LowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort7Entry 36 } ramosOptimaThermostatTemperatureArrayPort7LowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort7Entry 37 } ramosOptimaThermostatTemperatureArrayPort7NormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort7Entry 38 } ramosOptimaThermostatTemperatureArrayPort7HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort7Entry 39 } ramosOptimaThermostatTemperatureArrayPort7HighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort7Entry 40 } ramosOptimaThermostatTemperatureArrayPort7LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort7Entry 41 } ramosOptimaThermostatTemperatureArrayPort7LowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort7Entry 42 } ramosOptimaThermostatTemperatureArrayPort7EnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTemperatureArrayPort7Entry 43 } ramosOptimaTemperatureArrayPort8 OBJECT IDENTIFIER ::= { ramosOptimaTemperatureArraySensor 8 } ramosOptimaTemperatureArrayPort8Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the TemperatureArray." ::= { ramosOptimaTemperatureArrayPort8 1 } ramosOptimaTemperatureArrayPort8Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaTemperatureArrayPort8Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor." ::= { ramosOptimaTemperatureArrayPort8 2 } ramosOptimaTemperatureArrayPort8Entry OBJECT-TYPE SYNTAX RamosOptimaTemperatureArrayPort8Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaTemperatureArrayPort8 Table" INDEX { ramosOptimaTemperatureArrayPort8Index } ::= { ramosOptimaTemperatureArrayPort8Table 1 } RamosOptimaTemperatureArrayPort8Entry ::= SEQUENCE { ramosOptimaTemperatureArrayPort8Index INTEGER, ramosOptimaTemperatureArrayPort8Description DisplayString, ramosOptimaTemperatureArrayPort8Value INTEGER, ramosOptimaTemperatureArrayPort8Status INTEGER, ramosOptimaTemperatureArrayPort8Online INTEGER, ramosOptimaTemperatureArrayPort8GoOnline INTEGER, ramosOptimaTemperatureArrayPort8HighWarning INTEGER, ramosOptimaTemperatureArrayPort8HighCritical INTEGER, ramosOptimaTemperatureArrayPort8LowWarning INTEGER, ramosOptimaTemperatureArrayPort8LowCritical INTEGER, ramosOptimaTemperatureArrayPort8Rearm INTEGER, ramosOptimaTemperatureArrayPort8DegreeType INTEGER, ramosOptimaTemperatureArrayPort8DegreeRaw INTEGER, ramosOptimaTemperatureArrayPort8Offset INTEGER, ramosOptimaTemperatureArrayPort8URL DisplayString, ramosOptimaTemperatureArrayPort8OpenURL INTEGER, ramosOptimaTemperatureArrayPort8DatacollectType INTEGER, ramosOptimaTemperatureArrayPort8ContTimeHighCritical INTEGER, ramosOptimaTemperatureArrayPort8ContTimeHighWarning INTEGER, ramosOptimaTemperatureArrayPort8ContTimeNormal INTEGER, ramosOptimaTemperatureArrayPort8ContTimeLowWarning INTEGER, ramosOptimaTemperatureArrayPort8ContTimeLowCritical INTEGER, ramosOptimaTemperatureArrayPort8ContTimeSensorError INTEGER, ramosOptimaTemperatureArrayPort8Calendar INTEGER, ramosOptimaThermostatTemperatureArrayPort8Index INTEGER, ramosOptimaThermostatTemperatureArrayPort8Description DisplayString, ramosOptimaThermostatTemperatureArrayPort8Value INTEGER, ramosOptimaThermostatTemperatureArrayPort8Online INTEGER, ramosOptimaThermostatTemperatureArrayPort8GoOnline INTEGER, ramosOptimaThermostatTemperatureArrayPort8Mode INTEGER, ramosOptimaThermostatTemperatureArrayPort8RelayControlPort INTEGER, ramosOptimaThermostatTemperatureArrayPort8NormalAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort8HighLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort8HighLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort8LowLimit1 INTEGER, ramosOptimaThermostatTemperatureArrayPort8LowLimitAction1 INTEGER, ramosOptimaThermostatTemperatureArrayPort8NormalAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort8HighLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort8HighLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort8LowLimit2 INTEGER, ramosOptimaThermostatTemperatureArrayPort8LowLimitAction2 INTEGER, ramosOptimaThermostatTemperatureArrayPort8EnableTime DisplayString } ramosOptimaTemperatureArrayPort8Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor TemperatureArray port." ::= { ramosOptimaTemperatureArrayPort8Entry 1 } ramosOptimaTemperatureArrayPort8Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor TemperatureArray" ::= { ramosOptimaTemperatureArrayPort8Entry 2 } ramosOptimaTemperatureArrayPort8Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort8Entry 3 } ramosOptimaTemperatureArrayPort8Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaTemperatureArrayPort8Entry 4 } ramosOptimaTemperatureArrayPort8Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort8Entry 5 } ramosOptimaTemperatureArrayPort8GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort8Entry 6 } ramosOptimaTemperatureArrayPort8HighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort8Entry 7 } ramosOptimaTemperatureArrayPort8HighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort8Entry 8 } ramosOptimaTemperatureArrayPort8LowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaTemperatureArrayPort8Entry 9 } ramosOptimaTemperatureArrayPort8LowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaTemperatureArrayPort8Entry 10 } ramosOptimaTemperatureArrayPort8Rearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { ramosOptimaTemperatureArrayPort8Entry 11 } ramosOptimaTemperatureArrayPort8DegreeType OBJECT-TYPE SYNTAX INTEGER { fahr(0), celsius(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The degrees are in fahrenheit(0) or in celsius(1)" ::= { ramosOptimaTemperatureArrayPort8Entry 12 } ramosOptimaTemperatureArrayPort8DegreeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { ramosOptimaTemperatureArrayPort8Entry 14 } ramosOptimaTemperatureArrayPort8Offset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset reading" ::= { ramosOptimaTemperatureArrayPort8Entry 15 } ramosOptimaTemperatureArrayPort8URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaTemperatureArrayPort8Entry 16 } ramosOptimaTemperatureArrayPort8OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaTemperatureArrayPort8Entry 17 } ramosOptimaTemperatureArrayPort8DatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaTemperatureArrayPort8Entry 18 } ramosOptimaTemperatureArrayPort8ContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort8Entry 19 } ramosOptimaTemperatureArrayPort8ContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort8Entry 20 } ramosOptimaTemperatureArrayPort8ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaTemperatureArrayPort8Entry 21 } ramosOptimaTemperatureArrayPort8ContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaTemperatureArrayPort8Entry 22 } ramosOptimaTemperatureArrayPort8ContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaTemperatureArrayPort8Entry 23 } ramosOptimaTemperatureArrayPort8ContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaTemperatureArrayPort8Entry 24 } ramosOptimaTemperatureArrayPort8Calendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaTemperatureArrayPort8Entry 25 } ramosOptimaThermostatTemperatureArrayPort8Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor thermostat port." ::= { ramosOptimaTemperatureArrayPort8Entry 26 } ramosOptimaThermostatTemperatureArrayPort8Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor thermostat" ::= { ramosOptimaTemperatureArrayPort8Entry 27 } ramosOptimaThermostatTemperatureArrayPort8Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaTemperatureArrayPort8Entry 28 } ramosOptimaThermostatTemperatureArrayPort8Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaTemperatureArrayPort8Entry 29 } ramosOptimaThermostatTemperatureArrayPort8GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaTemperatureArrayPort8Entry 30 } ramosOptimaThermostatTemperatureArrayPort8Mode OBJECT-TYPE SYNTAX INTEGER { normal(0), time-bases(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select the thermostat mode for working on time-bases(1) or normal(0)." ::= { ramosOptimaTemperatureArrayPort8Entry 31 } ramosOptimaThermostatTemperatureArrayPort8RelayControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "To select a relay port to be controled by this thermostat sensor." ::= { ramosOptimaTemperatureArrayPort8Entry 32 } ramosOptimaThermostatTemperatureArrayPort8NormalAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort8Entry 33 } ramosOptimaThermostatTemperatureArrayPort8HighLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort8Entry 34 } ramosOptimaThermostatTemperatureArrayPort8HighLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort8Entry 35 } ramosOptimaThermostatTemperatureArrayPort8LowLimit1 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort8Entry 36 } ramosOptimaThermostatTemperatureArrayPort8LowLimitAction1 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile1: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort8Entry 37 } ramosOptimaThermostatTemperatureArrayPort8NormalAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat normal action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort8Entry 38 } ramosOptimaThermostatTemperatureArrayPort8HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat high limit, it will take a high limit action." ::= { ramosOptimaTemperatureArrayPort8Entry 39 } ramosOptimaThermostatTemperatureArrayPort8HighLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat high limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort8Entry 40 } ramosOptimaThermostatTemperatureArrayPort8LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-40..167) ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action." ::= { ramosOptimaTemperatureArrayPort8Entry 41 } ramosOptimaThermostatTemperatureArrayPort8LowLimitAction2 OBJECT-TYPE SYNTAX INTEGER { turn-on(0), turn-off(1), no-change(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Profile2: Thermostat low limit action for controlling a relay sensor." ::= { ramosOptimaTemperatureArrayPort8Entry 42 } ramosOptimaThermostatTemperatureArrayPort8EnableTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time to enable on Thermostat" ::= { ramosOptimaTemperatureArrayPort8Entry 43 } ramosOptimaNoCameraSensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 34 } ramosOptimaNoCameraSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of no camera sensor port." ::= { ramosOptimaNoCameraSensor 1 } ramosOptimaNoCameraSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaNoCameraSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every no camera Sensor. Each row in the table contains data for a different NoCamera Sensor." ::= { ramosOptimaNoCameraSensor 2 } ramosOptimaNoCameraSensorEntry OBJECT-TYPE SYNTAX RamosOptimaNoCameraSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaNoCameraSensorEntry Table" INDEX { ramosOptimaNoCameraSensorIndex } ::= { ramosOptimaNoCameraSensorTable 1 } RamosOptimaNoCameraSensorEntry ::= SEQUENCE { ramosOptimaNoCameraSensorIndex INTEGER, ramosOptimaNoCameraDescription DisplayString, ramosOptimaNoCameraStatus INTEGER, ramosOptimaNoCameraOnline INTEGER, ramosOptimaNoCameraGoOnline INTEGER, ramosOptimaNoCameraContTimeHighCritical INTEGER, ramosOptimaNoCameraContTimeNormal INTEGER, ramosOptimaNoCameraCalendar INTEGER } ramosOptimaNoCameraSensorIndex OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each no camera sensor port." ::= { ramosOptimaNoCameraSensorEntry 1 } ramosOptimaNoCameraDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { ramosOptimaNoCameraSensorEntry 2 } ramosOptimaNoCameraStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor." ::= { ramosOptimaNoCameraSensorEntry 4 } ramosOptimaNoCameraOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaNoCameraSensorEntry 5 } ramosOptimaNoCameraGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaNoCameraSensorEntry 6 } ramosOptimaNoCameraContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaNoCameraSensorEntry 7 } ramosOptimaNoCameraContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaNoCameraSensorEntry 8 } ramosOptimaNoCameraCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaNoCameraSensorEntry 9 } ramosOptimaSoftMotionSensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 35 } ramosOptimaSoftMotionSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SoftMotionSensor port." ::= { ramosOptimaSoftMotionSensor 1 } ramosOptimaSoftMotionSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaSoftMotionSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every SoftMotion Sensor. Each row in the table contains data for a different SoftMotion Sensor." ::= { ramosOptimaSoftMotionSensor 2 } ramosOptimaSoftMotionSensorEntry OBJECT-TYPE SYNTAX RamosOptimaSoftMotionSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaSoftMotionSensorEntry Table" INDEX { ramosOptimaSoftMotionSensorIndex } ::= { ramosOptimaSoftMotionSensorTable 1 } RamosOptimaSoftMotionSensorEntry ::= SEQUENCE { ramosOptimaSoftMotionSensorIndex INTEGER, ramosOptimaSoftMotionDescription DisplayString, ramosOptimaSoftMotionStatus INTEGER, ramosOptimaSoftMotionOnline INTEGER, ramosOptimaSoftMotionGoOnline INTEGER, ramosOptimaSoftMotionPercentSensitivity INTEGER, ramosOptimaSoftMotionURL DisplayString, ramosOptimaSoftMotionOpenURL INTEGER, ramosOptimaSoftMotionContTimeHighCritical INTEGER, ramosOptimaSoftMotionContTimeNormal INTEGER, ramosOptimaSoftMotionCalendar INTEGER, ramosOptimaSoftMotionMask INTEGER } ramosOptimaSoftMotionSensorIndex OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each soft motion sensor port." ::= { ramosOptimaSoftMotionSensorEntry 1 } ramosOptimaSoftMotionDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { ramosOptimaSoftMotionSensorEntry 2 } ramosOptimaSoftMotionStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor." ::= { ramosOptimaSoftMotionSensorEntry 4 } ramosOptimaSoftMotionOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaSoftMotionSensorEntry 5 } ramosOptimaSoftMotionGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaSoftMotionSensorEntry 6 } ramosOptimaSoftMotionPercentSensitivity OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The percent of sensitivity uses for setting the sentisitivity of motion detector." ::= { ramosOptimaSoftMotionSensorEntry 7 } ramosOptimaSoftMotionURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaSoftMotionSensorEntry 8 } ramosOptimaSoftMotionOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaSoftMotionSensorEntry 9 } ramosOptimaSoftMotionContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaSoftMotionSensorEntry 10 } ramosOptimaSoftMotionContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaSoftMotionSensorEntry 11 } ramosOptimaSoftMotionCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaSoftMotionSensorEntry 12 } ramosOptimaSoftMotionMask OBJECT-TYPE SYNTAX INTEGER (0..33554431) ACCESS read-write STATUS mandatory DESCRIPTION "Mask of enable or disable of SoftMotion." ::= { ramosOptimaSoftMotionSensorEntry 13 } ramosOptimaSoundDetectorSensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 36 } ramosOptimaSoundDetectorSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SoundDetectorSensor port." ::= { ramosOptimaSoundDetectorSensor 1 } ramosOptimaSoundDetectorSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaSoundDetectorSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every SoundDetectorSensor Sensor. Each row in the table contains data for a different SoundDetectorSensor Sensor." ::= { ramosOptimaSoundDetectorSensor 2 } ramosOptimaSoundDetectorSensorEntry OBJECT-TYPE SYNTAX RamosOptimaSoundDetectorSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaSoundDetectorSensorEntry Table" INDEX { ramosOptimaSoundDetectorIndex } ::= { ramosOptimaSoundDetectorSensorTable 1 } RamosOptimaSoundDetectorSensorEntry ::= SEQUENCE { ramosOptimaSoundDetectorIndex INTEGER, ramosOptimaSoundDetectorDescription DisplayString, ramosOptimaSoundDetectorValue INTEGER, ramosOptimaSoundDetectorStatus INTEGER, ramosOptimaSoundDetectorOnline INTEGER, ramosOptimaSoundDetectorGoOnline INTEGER, ramosOptimaSoundDetectorHighWarning INTEGER, ramosOptimaSoundDetectorHighCritical INTEGER, ramosOptimaSoundDetectorLowWarning INTEGER, ramosOptimaSoundDetectorLowCritical INTEGER, ramosOptimaSoundDetectorRearm INTEGER, ramosOptimaSoundDetectorRecordingSource INTEGER, ramosOptimaSoundDetectorMicBoost INTEGER, ramosOptimaSoundDetectorMicSensitivity INTEGER, ramosOptimaSoundDetectorPulseLength INTEGER, ramosOptimaSoundDetectorURL DisplayString, ramosOptimaSoundDetectorOpenURL INTEGER, ramosOptimaSoundDetectorDatacollectType INTEGER, ramosOptimaSoundDetectorContTimeHighCritical INTEGER, ramosOptimaSoundDetectorContTimeHighWarning INTEGER, ramosOptimaSoundDetectorContTimeNormal INTEGER, ramosOptimaSoundDetectorContTimeLowWarning INTEGER, ramosOptimaSoundDetectorContTimeLowCritical INTEGER, ramosOptimaSoundDetectorContTimeSensorError INTEGER, ramosOptimaSoundDetectorCalendar INTEGER } ramosOptimaSoundDetectorIndex OBJECT-TYPE SYNTAX INTEGER (0) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sound detector sensor port." ::= { ramosOptimaSoundDetectorSensorEntry 1 } ramosOptimaSoundDetectorDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { ramosOptimaSoundDetectorSensorEntry 2 } ramosOptimaSoundDetectorValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { ramosOptimaSoundDetectorSensorEntry 3 } ramosOptimaSoundDetectorStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaSoundDetectorSensorEntry 4 } ramosOptimaSoundDetectorOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaSoundDetectorSensorEntry 5 } ramosOptimaSoundDetectorGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaSoundDetectorSensorEntry 6 } ramosOptimaSoundDetectorHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { ramosOptimaSoundDetectorSensorEntry 7 } ramosOptimaSoundDetectorHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { ramosOptimaSoundDetectorSensorEntry 8 } ramosOptimaSoundDetectorLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { ramosOptimaSoundDetectorSensorEntry 9 } ramosOptimaSoundDetectorLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { ramosOptimaSoundDetectorSensorEntry 10 } ramosOptimaSoundDetectorRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down Rearm degrees below warning before the status goes to normal" ::= { ramosOptimaSoundDetectorSensorEntry 11 } ramosOptimaSoundDetectorRecordingSource OBJECT-TYPE SYNTAX INTEGER { internal-mic(0), line-in(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To select a recording source being in internal microphone(0) or in line-in(1)." ::= { ramosOptimaSoundDetectorSensorEntry 12 } ramosOptimaSoundDetectorMicBoost OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable a microphone boost(+20 db)." ::= { ramosOptimaSoundDetectorSensorEntry 13 } ramosOptimaSoundDetectorMicSensitivity OBJECT-TYPE SYNTAX INTEGER { i0(0), i20(20), i40(40), i60(60), i80(80), i100(100) } ACCESS read-write STATUS mandatory DESCRIPTION "The sensitivity of microphone to detect sound." ::= { ramosOptimaSoundDetectorSensorEntry 14 } ramosOptimaSoundDetectorPulseLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for detecting before changing status." ::= { ramosOptimaSoundDetectorSensorEntry 15 } ramosOptimaSoundDetectorURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaSoundDetectorSensorEntry 16 } ramosOptimaSoundDetectorOpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaSoundDetectorSensorEntry 17 } ramosOptimaSoundDetectorDatacollectType OBJECT-TYPE SYNTAX INTEGER { average(1), highest(2), lowest(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of datacollect to collect." ::= { ramosOptimaSoundDetectorSensorEntry 18 } ramosOptimaSoundDetectorContTimeHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { ramosOptimaSoundDetectorSensorEntry 19 } ramosOptimaSoundDetectorContTimeHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { ramosOptimaSoundDetectorSensorEntry 20 } ramosOptimaSoundDetectorContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaSoundDetectorSensorEntry 21 } ramosOptimaSoundDetectorContTimeLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { ramosOptimaSoundDetectorSensorEntry 22 } ramosOptimaSoundDetectorContTimeLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { ramosOptimaSoundDetectorSensorEntry 23 } ramosOptimaSoundDetectorContTimeSensorError OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Sensor Error before accepting new Status." ::= { ramosOptimaSoundDetectorSensorEntry 24 } ramosOptimaSoundDetectorCalendar OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the calendar filtering working hours of sensor." ::= { ramosOptimaSoundDetectorSensorEntry 25 } ramosOptimaDrycontactArraySensor OBJECT IDENTIFIER ::= { ramosOptimaOtherSensor 37 } ramosOptimaDrycontactArrayPort1 OBJECT IDENTIFIER ::= { ramosOptimaDrycontactArraySensor 1 } ramosOptimaDrycontactArrayPort1Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the DrycontactArray." ::= { ramosOptimaDrycontactArrayPort1 1 } ramosOptimaDrycontactArrayPort1Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaDrycontactArrayPort1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor." ::= { ramosOptimaDrycontactArrayPort1 2 } ramosOptimaDrycontactArrayPort1Entry OBJECT-TYPE SYNTAX RamosOptimaDrycontactArrayPort1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaDrycontactArrayPort1 Table" INDEX { ramosOptimaDrycontactArrayPort1Index } ::= { ramosOptimaDrycontactArrayPort1Table 1 } RamosOptimaDrycontactArrayPort1Entry ::= SEQUENCE { ramosOptimaDrycontactArrayPort1Index INTEGER, ramosOptimaDrycontactArrayPort1Description DisplayString, ramosOptimaDrycontactArrayPort1Status INTEGER, ramosOptimaDrycontactArrayPort1Online INTEGER, ramosOptimaDrycontactArrayPort1GoOnline INTEGER, ramosOptimaDrycontactArrayPort1NormalState INTEGER, ramosOptimaDrycontactArrayPort1Direction INTEGER, ramosOptimaDrycontactArrayPort1ContTimeCritical INTEGER, ramosOptimaDrycontactArrayPort1ContTimeNormal INTEGER, ramosOptimaDrycontactArrayPort1ManualOutputCycleTime INTEGER, ramosOptimaDrycontactArrayPort1ManualOutputAction INTEGER, ramosOptimaDrycontactArrayPort1OutputDescOn DisplayString, ramosOptimaDrycontactArrayPort1OutputDescOff DisplayString, ramosOptimaDrycontactArrayPort1URL DisplayString, ramosOptimaDrycontactArrayPort1OpenURL INTEGER, ramosOptimaDrycontactArrayPort1ControlMode INTEGER } ramosOptimaDrycontactArrayPort1Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor DrycontactArray port." ::= { ramosOptimaDrycontactArrayPort1Entry 1 } ramosOptimaDrycontactArrayPort1Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor DrycontactArray" ::= { ramosOptimaDrycontactArrayPort1Entry 2 } ramosOptimaDrycontactArrayPort1Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaDrycontactArrayPort1Entry 4 } ramosOptimaDrycontactArrayPort1Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaDrycontactArrayPort1Entry 5 } ramosOptimaDrycontactArrayPort1GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaDrycontactArrayPort1Entry 6 } ramosOptimaDrycontactArrayPort1NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of DrycontactArray" ::= { ramosOptimaDrycontactArrayPort1Entry 7 } ramosOptimaDrycontactArrayPort1Direction OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a drycontact to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaDrycontactArrayPort1Entry 8 } ramosOptimaDrycontactArrayPort1ContTimeCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Critical before accepting new Status." ::= { ramosOptimaDrycontactArrayPort1Entry 9 } ramosOptimaDrycontactArrayPort1ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaDrycontactArrayPort1Entry 10 } ramosOptimaDrycontactArrayPort1ManualOutputCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Drycontact output toggle period in seconds for Manual Cycle action." ::= { ramosOptimaDrycontactArrayPort1Entry 24 } ramosOptimaDrycontactArrayPort1ManualOutputAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the drycontact output manualy" ::= { ramosOptimaDrycontactArrayPort1Entry 25 } ramosOptimaDrycontactArrayPort1OutputDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output On" ::= { ramosOptimaDrycontactArrayPort1Entry 26 } ramosOptimaDrycontactArrayPort1OutputDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output Off" ::= { ramosOptimaDrycontactArrayPort1Entry 27 } ramosOptimaDrycontactArrayPort1URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sersor URL link." ::= { ramosOptimaDrycontactArrayPort1Entry 28 } ramosOptimaDrycontactArrayPort1OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaDrycontactArrayPort1Entry 29 } ramosOptimaDrycontactArrayPort1ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a drycontact output." ::= { ramosOptimaDrycontactArrayPort1Entry 30 } ramosOptimaDrycontactArrayPort2 OBJECT IDENTIFIER ::= { ramosOptimaDrycontactArraySensor 2 } ramosOptimaDrycontactArrayPort2Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the DrycontactArray." ::= { ramosOptimaDrycontactArrayPort2 1 } ramosOptimaDrycontactArrayPort2Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaDrycontactArrayPort2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor." ::= { ramosOptimaDrycontactArrayPort2 2 } ramosOptimaDrycontactArrayPort2Entry OBJECT-TYPE SYNTAX RamosOptimaDrycontactArrayPort2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaDrycontactArrayPort2 Table" INDEX { ramosOptimaDrycontactArrayPort2Index } ::= { ramosOptimaDrycontactArrayPort2Table 1 } RamosOptimaDrycontactArrayPort2Entry ::= SEQUENCE { ramosOptimaDrycontactArrayPort2Index INTEGER, ramosOptimaDrycontactArrayPort2Description DisplayString, ramosOptimaDrycontactArrayPort2Status INTEGER, ramosOptimaDrycontactArrayPort2Online INTEGER, ramosOptimaDrycontactArrayPort2GoOnline INTEGER, ramosOptimaDrycontactArrayPort2NormalState INTEGER, ramosOptimaDrycontactArrayPort2Direction INTEGER, ramosOptimaDrycontactArrayPort2ContTimeCritical INTEGER, ramosOptimaDrycontactArrayPort2ContTimeNormal INTEGER, ramosOptimaDrycontactArrayPort2ManualOutputCycleTime INTEGER, ramosOptimaDrycontactArrayPort2ManualOutputAction INTEGER, ramosOptimaDrycontactArrayPort2OutputDescOn DisplayString, ramosOptimaDrycontactArrayPort2OutputDescOff DisplayString, ramosOptimaDrycontactArrayPort2URL DisplayString, ramosOptimaDrycontactArrayPort2OpenURL INTEGER, ramosOptimaDrycontactArrayPort2ControlMode INTEGER } ramosOptimaDrycontactArrayPort2Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor DrycontactArray port." ::= { ramosOptimaDrycontactArrayPort2Entry 1 } ramosOptimaDrycontactArrayPort2Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor DrycontactArray" ::= { ramosOptimaDrycontactArrayPort2Entry 2 } ramosOptimaDrycontactArrayPort2Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaDrycontactArrayPort2Entry 4 } ramosOptimaDrycontactArrayPort2Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaDrycontactArrayPort2Entry 5 } ramosOptimaDrycontactArrayPort2GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaDrycontactArrayPort2Entry 6 } ramosOptimaDrycontactArrayPort2NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of DrycontactArray" ::= { ramosOptimaDrycontactArrayPort2Entry 7 } ramosOptimaDrycontactArrayPort2Direction OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a drycontact to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaDrycontactArrayPort2Entry 8 } ramosOptimaDrycontactArrayPort2ContTimeCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Critical before accepting new Status." ::= { ramosOptimaDrycontactArrayPort2Entry 9 } ramosOptimaDrycontactArrayPort2ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaDrycontactArrayPort2Entry 10 } ramosOptimaDrycontactArrayPort2ManualOutputCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Drycontact toggle period in seconds for Manual Cycle action." ::= { ramosOptimaDrycontactArrayPort2Entry 24 } ramosOptimaDrycontactArrayPort2ManualOutputAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the Drycontact output manualy" ::= { ramosOptimaDrycontactArrayPort2Entry 25 } ramosOptimaDrycontactArrayPort2OutputDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output On" ::= { ramosOptimaDrycontactArrayPort2Entry 26 } ramosOptimaDrycontactArrayPort2OutputDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output Off" ::= { ramosOptimaDrycontactArrayPort2Entry 27 } ramosOptimaDrycontactArrayPort2URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link" ::= { ramosOptimaDrycontactArrayPort2Entry 28 } ramosOptimaDrycontactArrayPort2OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaDrycontactArrayPort2Entry 29 } ramosOptimaDrycontactArrayPort2ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a Drycontact output." ::= { ramosOptimaDrycontactArrayPort2Entry 30 } ramosOptimaDrycontactArrayPort3 OBJECT IDENTIFIER ::= { ramosOptimaDrycontactArraySensor 3 } ramosOptimaDrycontactArrayPort3Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the DrycontactArray." ::= { ramosOptimaDrycontactArrayPort3 1 } ramosOptimaDrycontactArrayPort3Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaDrycontactArrayPort3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor." ::= { ramosOptimaDrycontactArrayPort3 2 } ramosOptimaDrycontactArrayPort3Entry OBJECT-TYPE SYNTAX RamosOptimaDrycontactArrayPort3Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaDrycontactArrayPort3 Table" INDEX { ramosOptimaDrycontactArrayPort3Index } ::= { ramosOptimaDrycontactArrayPort3Table 1 } RamosOptimaDrycontactArrayPort3Entry ::= SEQUENCE { ramosOptimaDrycontactArrayPort3Index INTEGER, ramosOptimaDrycontactArrayPort3Description DisplayString, ramosOptimaDrycontactArrayPort3Status INTEGER, ramosOptimaDrycontactArrayPort3Online INTEGER, ramosOptimaDrycontactArrayPort3GoOnline INTEGER, ramosOptimaDrycontactArrayPort3NormalState INTEGER, ramosOptimaDrycontactArrayPort3Direction INTEGER, ramosOptimaDrycontactArrayPort3ContTimeCritical INTEGER, ramosOptimaDrycontactArrayPort3ContTimeNormal INTEGER, ramosOptimaDrycontactArrayPort3ManualOutputCycleTime INTEGER, ramosOptimaDrycontactArrayPort3ManualOutputAction INTEGER, ramosOptimaDrycontactArrayPort3OutputDescOn DisplayString, ramosOptimaDrycontactArrayPort3OutputDescOff DisplayString, ramosOptimaDrycontactArrayPort3URL DisplayString, ramosOptimaDrycontactArrayPort3OpenURL INTEGER, ramosOptimaDrycontactArrayPort3ControlMode INTEGER } ramosOptimaDrycontactArrayPort3Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor DrycontactArray port." ::= { ramosOptimaDrycontactArrayPort3Entry 1 } ramosOptimaDrycontactArrayPort3Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor DrycontactArray" ::= { ramosOptimaDrycontactArrayPort3Entry 2 } ramosOptimaDrycontactArrayPort3Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaDrycontactArrayPort3Entry 4 } ramosOptimaDrycontactArrayPort3Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaDrycontactArrayPort3Entry 5 } ramosOptimaDrycontactArrayPort3GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaDrycontactArrayPort3Entry 6 } ramosOptimaDrycontactArrayPort3NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of DrycontactArray" ::= { ramosOptimaDrycontactArrayPort3Entry 7 } ramosOptimaDrycontactArrayPort3Direction OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a drycontact to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaDrycontactArrayPort3Entry 8 } ramosOptimaDrycontactArrayPort3ContTimeCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Critical before accepting new Status." ::= { ramosOptimaDrycontactArrayPort3Entry 9 } ramosOptimaDrycontactArrayPort3ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaDrycontactArrayPort3Entry 10 } ramosOptimaDrycontactArrayPort3ManualOutputCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Drycontact toggle period in seconds for Manual Cycle action." ::= { ramosOptimaDrycontactArrayPort3Entry 24 } ramosOptimaDrycontactArrayPort3ManualOutputAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the Drycontact output manualy" ::= { ramosOptimaDrycontactArrayPort3Entry 25 } ramosOptimaDrycontactArrayPort3OutputDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output On" ::= { ramosOptimaDrycontactArrayPort3Entry 26 } ramosOptimaDrycontactArrayPort3OutputDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output Off" ::= { ramosOptimaDrycontactArrayPort3Entry 27 } ramosOptimaDrycontactArrayPort3URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaDrycontactArrayPort3Entry 28 } ramosOptimaDrycontactArrayPort3OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaDrycontactArrayPort3Entry 29 } ramosOptimaDrycontactArrayPort3ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a Drycontact output." ::= { ramosOptimaDrycontactArrayPort3Entry 30 } ramosOptimaDrycontactArrayPort4 OBJECT IDENTIFIER ::= { ramosOptimaDrycontactArraySensor 4 } ramosOptimaDrycontactArrayPort4Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the DrycontactArray." ::= { ramosOptimaDrycontactArrayPort4 1 } ramosOptimaDrycontactArrayPort4Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaDrycontactArrayPort4Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor." ::= { ramosOptimaDrycontactArrayPort4 2 } ramosOptimaDrycontactArrayPort4Entry OBJECT-TYPE SYNTAX RamosOptimaDrycontactArrayPort4Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaDrycontactArrayPort4 Table" INDEX { ramosOptimaDrycontactArrayPort4Index } ::= { ramosOptimaDrycontactArrayPort4Table 1 } RamosOptimaDrycontactArrayPort4Entry ::= SEQUENCE { ramosOptimaDrycontactArrayPort4Index INTEGER, ramosOptimaDrycontactArrayPort4Description DisplayString, ramosOptimaDrycontactArrayPort4Status INTEGER, ramosOptimaDrycontactArrayPort4Online INTEGER, ramosOptimaDrycontactArrayPort4GoOnline INTEGER, ramosOptimaDrycontactArrayPort4NormalState INTEGER, ramosOptimaDrycontactArrayPort4Direction INTEGER, ramosOptimaDrycontactArrayPort4ContTimeCritical INTEGER, ramosOptimaDrycontactArrayPort4ContTimeNormal INTEGER, ramosOptimaDrycontactArrayPort4ManualOutputCycleTime INTEGER, ramosOptimaDrycontactArrayPort4ManualOutputAction INTEGER, ramosOptimaDrycontactArrayPort4OutputDescOn DisplayString, ramosOptimaDrycontactArrayPort4OutputDescOff DisplayString, ramosOptimaDrycontactArrayPort4URL DisplayString, ramosOptimaDrycontactArrayPort4OpenURL INTEGER, ramosOptimaDrycontactArrayPort4ControlMode INTEGER } ramosOptimaDrycontactArrayPort4Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor DrycontactArray port." ::= { ramosOptimaDrycontactArrayPort4Entry 1 } ramosOptimaDrycontactArrayPort4Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor DrycontactArray" ::= { ramosOptimaDrycontactArrayPort4Entry 2 } ramosOptimaDrycontactArrayPort4Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaDrycontactArrayPort4Entry 4 } ramosOptimaDrycontactArrayPort4Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaDrycontactArrayPort4Entry 5 } ramosOptimaDrycontactArrayPort4GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaDrycontactArrayPort4Entry 6 } ramosOptimaDrycontactArrayPort4NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of DrycontactArray" ::= { ramosOptimaDrycontactArrayPort4Entry 7 } ramosOptimaDrycontactArrayPort4Direction OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a drycontact to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaDrycontactArrayPort4Entry 8 } ramosOptimaDrycontactArrayPort4ContTimeCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Critical before accepting new Status." ::= { ramosOptimaDrycontactArrayPort4Entry 9 } ramosOptimaDrycontactArrayPort4ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaDrycontactArrayPort4Entry 10 } ramosOptimaDrycontactArrayPort4ManualOutputCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Drycontact toggle period in seconds for Manual Cycle action." ::= { ramosOptimaDrycontactArrayPort4Entry 24 } ramosOptimaDrycontactArrayPort4ManualOutputAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the Drycontact output manualy" ::= { ramosOptimaDrycontactArrayPort4Entry 25 } ramosOptimaDrycontactArrayPort4OutputDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output On" ::= { ramosOptimaDrycontactArrayPort4Entry 26 } ramosOptimaDrycontactArrayPort4OutputDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output Off" ::= { ramosOptimaDrycontactArrayPort4Entry 27 } ramosOptimaDrycontactArrayPort4URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaDrycontactArrayPort4Entry 28 } ramosOptimaDrycontactArrayPort4OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaDrycontactArrayPort4Entry 29 } ramosOptimaDrycontactArrayPort4ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a Drycontact output." ::= { ramosOptimaDrycontactArrayPort4Entry 30 } ramosOptimaDrycontactArrayPort5 OBJECT IDENTIFIER ::= { ramosOptimaDrycontactArraySensor 5 } ramosOptimaDrycontactArrayPort5Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the DrycontactArray." ::= { ramosOptimaDrycontactArrayPort5 1 } ramosOptimaDrycontactArrayPort5Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaDrycontactArrayPort5Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor." ::= { ramosOptimaDrycontactArrayPort5 2 } ramosOptimaDrycontactArrayPort5Entry OBJECT-TYPE SYNTAX RamosOptimaDrycontactArrayPort5Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaDrycontactArrayPort5 Table" INDEX { ramosOptimaDrycontactArrayPort5Index } ::= { ramosOptimaDrycontactArrayPort5Table 1 } RamosOptimaDrycontactArrayPort5Entry ::= SEQUENCE { ramosOptimaDrycontactArrayPort5Index INTEGER, ramosOptimaDrycontactArrayPort5Description DisplayString, ramosOptimaDrycontactArrayPort5Status INTEGER, ramosOptimaDrycontactArrayPort5Online INTEGER, ramosOptimaDrycontactArrayPort5GoOnline INTEGER, ramosOptimaDrycontactArrayPort5NormalState INTEGER, ramosOptimaDrycontactArrayPort5Direction INTEGER, ramosOptimaDrycontactArrayPort5ContTimeCritical INTEGER, ramosOptimaDrycontactArrayPort5ContTimeNormal INTEGER, ramosOptimaDrycontactArrayPort5ManualOutputCycleTime INTEGER, ramosOptimaDrycontactArrayPort5ManualOutputAction INTEGER, ramosOptimaDrycontactArrayPort5OutputDescOn DisplayString, ramosOptimaDrycontactArrayPort5OutputDescOff DisplayString, ramosOptimaDrycontactArrayPort5URL DisplayString, ramosOptimaDrycontactArrayPort5OpenURL INTEGER, ramosOptimaDrycontactArrayPort5ControlMode INTEGER } ramosOptimaDrycontactArrayPort5Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor DrycontactArray port." ::= { ramosOptimaDrycontactArrayPort5Entry 1 } ramosOptimaDrycontactArrayPort5Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor DrycontactArray" ::= { ramosOptimaDrycontactArrayPort5Entry 2 } ramosOptimaDrycontactArrayPort5Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaDrycontactArrayPort5Entry 4 } ramosOptimaDrycontactArrayPort5Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaDrycontactArrayPort5Entry 5 } ramosOptimaDrycontactArrayPort5GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaDrycontactArrayPort5Entry 6 } ramosOptimaDrycontactArrayPort5NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of DrycontactArray" ::= { ramosOptimaDrycontactArrayPort5Entry 7 } ramosOptimaDrycontactArrayPort5Direction OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a drycontact to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaDrycontactArrayPort5Entry 8 } ramosOptimaDrycontactArrayPort5ContTimeCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Critical before accepting new Status." ::= { ramosOptimaDrycontactArrayPort5Entry 9 } ramosOptimaDrycontactArrayPort5ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaDrycontactArrayPort5Entry 10 } ramosOptimaDrycontactArrayPort5ManualOutputCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Drycontact toggle period in seconds for Manual Cycle action." ::= { ramosOptimaDrycontactArrayPort5Entry 24 } ramosOptimaDrycontactArrayPort5ManualOutputAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the Drycontact output manualy" ::= { ramosOptimaDrycontactArrayPort5Entry 25 } ramosOptimaDrycontactArrayPort5OutputDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output On" ::= { ramosOptimaDrycontactArrayPort5Entry 26 } ramosOptimaDrycontactArrayPort5OutputDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output Off" ::= { ramosOptimaDrycontactArrayPort5Entry 27 } ramosOptimaDrycontactArrayPort5URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaDrycontactArrayPort5Entry 28 } ramosOptimaDrycontactArrayPort5OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaDrycontactArrayPort5Entry 29 } ramosOptimaDrycontactArrayPort5ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a Drycontact output." ::= { ramosOptimaDrycontactArrayPort5Entry 30 } ramosOptimaDrycontactArrayPort6 OBJECT IDENTIFIER ::= { ramosOptimaDrycontactArraySensor 6 } ramosOptimaDrycontactArrayPort6Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the DrycontactArray." ::= { ramosOptimaDrycontactArrayPort6 1 } ramosOptimaDrycontactArrayPort6Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaDrycontactArrayPort6Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor." ::= { ramosOptimaDrycontactArrayPort6 2 } ramosOptimaDrycontactArrayPort6Entry OBJECT-TYPE SYNTAX RamosOptimaDrycontactArrayPort6Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaDrycontactArrayPort6 Table" INDEX { ramosOptimaDrycontactArrayPort6Index } ::= { ramosOptimaDrycontactArrayPort6Table 1 } RamosOptimaDrycontactArrayPort6Entry ::= SEQUENCE { ramosOptimaDrycontactArrayPort6Index INTEGER, ramosOptimaDrycontactArrayPort6Description DisplayString, ramosOptimaDrycontactArrayPort6Status INTEGER, ramosOptimaDrycontactArrayPort6Online INTEGER, ramosOptimaDrycontactArrayPort6GoOnline INTEGER, ramosOptimaDrycontactArrayPort6NormalState INTEGER, ramosOptimaDrycontactArrayPort6Direction INTEGER, ramosOptimaDrycontactArrayPort6ContTimeCritical INTEGER, ramosOptimaDrycontactArrayPort6ContTimeNormal INTEGER, ramosOptimaDrycontactArrayPort6ManualOutputCycleTime INTEGER, ramosOptimaDrycontactArrayPort6ManualOutputAction INTEGER, ramosOptimaDrycontactArrayPort6OutputDescOn DisplayString, ramosOptimaDrycontactArrayPort6OutputDescOff DisplayString, ramosOptimaDrycontactArrayPort6URL DisplayString, ramosOptimaDrycontactArrayPort6OpenURL INTEGER, ramosOptimaDrycontactArrayPort6ControlMode INTEGER } ramosOptimaDrycontactArrayPort6Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor DrycontactArray port." ::= { ramosOptimaDrycontactArrayPort6Entry 1 } ramosOptimaDrycontactArrayPort6Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor DrycontactArray" ::= { ramosOptimaDrycontactArrayPort6Entry 2 } ramosOptimaDrycontactArrayPort6Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaDrycontactArrayPort6Entry 4 } ramosOptimaDrycontactArrayPort6Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaDrycontactArrayPort6Entry 5 } ramosOptimaDrycontactArrayPort6GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaDrycontactArrayPort6Entry 6 } ramosOptimaDrycontactArrayPort6NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of DrycontactArray" ::= { ramosOptimaDrycontactArrayPort6Entry 7 } ramosOptimaDrycontactArrayPort6Direction OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a drycontact to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaDrycontactArrayPort6Entry 8 } ramosOptimaDrycontactArrayPort6ContTimeCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Critical before accepting new Status." ::= { ramosOptimaDrycontactArrayPort6Entry 9 } ramosOptimaDrycontactArrayPort6ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaDrycontactArrayPort6Entry 10 } ramosOptimaDrycontactArrayPort6ManualOutputCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Drycontact toggle period in seconds for Manual Cycle action." ::= { ramosOptimaDrycontactArrayPort6Entry 24 } ramosOptimaDrycontactArrayPort6ManualOutputAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the Drycontact output manualy" ::= { ramosOptimaDrycontactArrayPort6Entry 25 } ramosOptimaDrycontactArrayPort6OutputDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output On" ::= { ramosOptimaDrycontactArrayPort6Entry 26 } ramosOptimaDrycontactArrayPort6OutputDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output Off" ::= { ramosOptimaDrycontactArrayPort6Entry 27 } ramosOptimaDrycontactArrayPort6URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaDrycontactArrayPort6Entry 28 } ramosOptimaDrycontactArrayPort6OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaDrycontactArrayPort6Entry 29 } ramosOptimaDrycontactArrayPort6ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a Drycontact output." ::= { ramosOptimaDrycontactArrayPort6Entry 30 } ramosOptimaDrycontactArrayPort7 OBJECT IDENTIFIER ::= { ramosOptimaDrycontactArraySensor 7 } ramosOptimaDrycontactArrayPort7Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the DrycontactArray." ::= { ramosOptimaDrycontactArrayPort7 1 } ramosOptimaDrycontactArrayPort7Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaDrycontactArrayPort7Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor." ::= { ramosOptimaDrycontactArrayPort7 2 } ramosOptimaDrycontactArrayPort7Entry OBJECT-TYPE SYNTAX RamosOptimaDrycontactArrayPort7Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaDrycontactArrayPort7 Table" INDEX { ramosOptimaDrycontactArrayPort7Index } ::= { ramosOptimaDrycontactArrayPort7Table 1 } RamosOptimaDrycontactArrayPort7Entry ::= SEQUENCE { ramosOptimaDrycontactArrayPort7Index INTEGER, ramosOptimaDrycontactArrayPort7Description DisplayString, ramosOptimaDrycontactArrayPort7Status INTEGER, ramosOptimaDrycontactArrayPort7Online INTEGER, ramosOptimaDrycontactArrayPort7GoOnline INTEGER, ramosOptimaDrycontactArrayPort7NormalState INTEGER, ramosOptimaDrycontactArrayPort7Direction INTEGER, ramosOptimaDrycontactArrayPort7ContTimeCritical INTEGER, ramosOptimaDrycontactArrayPort7ContTimeNormal INTEGER, ramosOptimaDrycontactArrayPort7ManualOutputCycleTime INTEGER, ramosOptimaDrycontactArrayPort7ManualOutputAction INTEGER, ramosOptimaDrycontactArrayPort7OutputDescOn DisplayString, ramosOptimaDrycontactArrayPort7OutputDescOff DisplayString, ramosOptimaDrycontactArrayPort7URL DisplayString, ramosOptimaDrycontactArrayPort7OpenURL INTEGER, ramosOptimaDrycontactArrayPort7ControlMode INTEGER } ramosOptimaDrycontactArrayPort7Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor DrycontactArray port." ::= { ramosOptimaDrycontactArrayPort7Entry 1 } ramosOptimaDrycontactArrayPort7Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor DrycontactArray" ::= { ramosOptimaDrycontactArrayPort7Entry 2 } ramosOptimaDrycontactArrayPort7Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaDrycontactArrayPort7Entry 4 } ramosOptimaDrycontactArrayPort7Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaDrycontactArrayPort7Entry 5 } ramosOptimaDrycontactArrayPort7GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaDrycontactArrayPort7Entry 6 } ramosOptimaDrycontactArrayPort7NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of DrycontactArray" ::= { ramosOptimaDrycontactArrayPort7Entry 7 } ramosOptimaDrycontactArrayPort7Direction OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a drycontact to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaDrycontactArrayPort7Entry 8 } ramosOptimaDrycontactArrayPort7ContTimeCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Critical before accepting new Status." ::= { ramosOptimaDrycontactArrayPort7Entry 9 } ramosOptimaDrycontactArrayPort7ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaDrycontactArrayPort7Entry 10 } ramosOptimaDrycontactArrayPort7ManualOutputCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Drycontact toggle period in seconds for Manual Cycle action." ::= { ramosOptimaDrycontactArrayPort7Entry 24 } ramosOptimaDrycontactArrayPort7ManualOutputAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the Drycontact output manualy" ::= { ramosOptimaDrycontactArrayPort7Entry 25 } ramosOptimaDrycontactArrayPort7OutputDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output On" ::= { ramosOptimaDrycontactArrayPort7Entry 26 } ramosOptimaDrycontactArrayPort7OutputDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output Off" ::= { ramosOptimaDrycontactArrayPort7Entry 27 } ramosOptimaDrycontactArrayPort7URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaDrycontactArrayPort7Entry 28 } ramosOptimaDrycontactArrayPort7OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaDrycontactArrayPort7Entry 29 } ramosOptimaDrycontactArrayPort7ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a Drycontact output." ::= { ramosOptimaDrycontactArrayPort7Entry 30 } ramosOptimaDrycontactArrayPort8 OBJECT IDENTIFIER ::= { ramosOptimaDrycontactArraySensor 8 } ramosOptimaDrycontactArrayPort8Number OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of port on the DrycontactArray." ::= { ramosOptimaDrycontactArrayPort8 1 } ramosOptimaDrycontactArrayPort8Table OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaDrycontactArrayPort8Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor." ::= { ramosOptimaDrycontactArrayPort8 2 } ramosOptimaDrycontactArrayPort8Entry OBJECT-TYPE SYNTAX RamosOptimaDrycontactArrayPort8Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaDrycontactArrayPort8 Table" INDEX { ramosOptimaDrycontactArrayPort8Index } ::= { ramosOptimaDrycontactArrayPort8Table 1 } RamosOptimaDrycontactArrayPort8Entry ::= SEQUENCE { ramosOptimaDrycontactArrayPort8Index INTEGER, ramosOptimaDrycontactArrayPort8Description DisplayString, ramosOptimaDrycontactArrayPort8Status INTEGER, ramosOptimaDrycontactArrayPort8Online INTEGER, ramosOptimaDrycontactArrayPort8GoOnline INTEGER, ramosOptimaDrycontactArrayPort8NormalState INTEGER, ramosOptimaDrycontactArrayPort8Direction INTEGER, ramosOptimaDrycontactArrayPort8ContTimeCritical INTEGER, ramosOptimaDrycontactArrayPort8ContTimeNormal INTEGER, ramosOptimaDrycontactArrayPort8ManualOutputCycleTime INTEGER, ramosOptimaDrycontactArrayPort8ManualOutputAction INTEGER, ramosOptimaDrycontactArrayPort8OutputDescOn DisplayString, ramosOptimaDrycontactArrayPort8OutputDescOff DisplayString, ramosOptimaDrycontactArrayPort8URL DisplayString, ramosOptimaDrycontactArrayPort8OpenURL INTEGER, ramosOptimaDrycontactArrayPort8ControlMode INTEGER } ramosOptimaDrycontactArrayPort8Index OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each sensor DrycontactArray port." ::= { ramosOptimaDrycontactArrayPort8Entry 1 } ramosOptimaDrycontactArrayPort8Description OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor DrycontactArray" ::= { ramosOptimaDrycontactArrayPort8Entry 2 } ramosOptimaDrycontactArrayPort8Status OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { ramosOptimaDrycontactArrayPort8Entry 4 } ramosOptimaDrycontactArrayPort8Online OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Sensor is currently online" ::= { ramosOptimaDrycontactArrayPort8Entry 5 } ramosOptimaDrycontactArrayPort8GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { ramosOptimaDrycontactArrayPort8Entry 6 } ramosOptimaDrycontactArrayPort8NormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of DrycontactArray" ::= { ramosOptimaDrycontactArrayPort8Entry 7 } ramosOptimaDrycontactArrayPort8Direction OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a drycontact to input enter 0. To set a switch to output enter 1" ::= { ramosOptimaDrycontactArrayPort8Entry 8 } ramosOptimaDrycontactArrayPort8ContTimeCritical OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Critical before accepting new Status." ::= { ramosOptimaDrycontactArrayPort8Entry 9 } ramosOptimaDrycontactArrayPort8ContTimeNormal OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Normal before accepting new Status." ::= { ramosOptimaDrycontactArrayPort8Entry 10 } ramosOptimaDrycontactArrayPort8ManualOutputCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Drycontact toggle period in seconds for Manual Cycle action." ::= { ramosOptimaDrycontactArrayPort8Entry 24 } ramosOptimaDrycontactArrayPort8ManualOutputAction OBJECT-TYPE SYNTAX INTEGER { allow-sensor-control(1), turn-on(3), turn-off(4), cycle-Off-On-Off(7), cycle-On-Off-On(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the Drycontact output manualy" ::= { ramosOptimaDrycontactArrayPort8Entry 25 } ramosOptimaDrycontactArrayPort8OutputDescOn OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output On" ::= { ramosOptimaDrycontactArrayPort8Entry 26 } ramosOptimaDrycontactArrayPort8OutputDescOff OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Description of Drycontact output Off" ::= { ramosOptimaDrycontactArrayPort8Entry 27 } ramosOptimaDrycontactArrayPort8URL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Sensor URL link." ::= { ramosOptimaDrycontactArrayPort8Entry 28 } ramosOptimaDrycontactArrayPort8OpenURL OBJECT-TYPE SYNTAX INTEGER { cur-window(0), new-window(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Open URL in this browser or open in a new window." ::= { ramosOptimaDrycontactArrayPort8Entry 29 } ramosOptimaDrycontactArrayPort8ControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), notification-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a Drycontact output." ::= { ramosOptimaDrycontactArrayPort8Entry 30 } ramosOptimaDebug OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS mandatory DESCRIPTION "SP only: Turn on or off debug messages" ::= { ramosOptimaEntry 20 } ramosOptimaTrapResend OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS mandatory DESCRIPTION "If traps for Warning or Error should be resent. Traps for Normal status are sent once" ::= { ramosOptimaEntry 22 } ramosOptimaTrapResendInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How often to resend mail or Traps. Enter the number of seconds from 15 to 65535. Mail for WARNING and ERROR are resent at this interval. Traps for Normal status are sent once" ::= { ramosOptimaEntry 23 } ramosOptimaSendTraps OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Turn on or off the sending of traps" ::= { ramosOptimaEntry 24 } ramosOptimaTrapDestination OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the trap destination" ::= { ramosOptimaEntry 25 } ramosOptimaTrapCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The community string of the trap destination" ::= { ramosOptimaEntry 26 } ramosOptimaDefaultGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "If the destination is on another network, enter the IP address of the router" ::= { ramosOptimaEntry 27 } ramosOptimaSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "If the trap destination uses the default gateway" ::= { ramosOptimaEntry 28 } ramosOptimaRouteAdd OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP only: Up to 4, Manual additions to the routing table in the form, Network IP Address, Netmask, Gateway IP address" ::= { ramosOptimaEntry 29 } ramosOptimaSendMail OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Turn on or off the sending of Mail" ::= { ramosOptimaEntry 30 } ramosOptimaMailRecpt OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The email address of the Recipient" ::= { ramosOptimaEntry 31 } ramosOptimaMailFrom OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The email address of the Sender" ::= { ramosOptimaEntry 32 } ramosOptimaMailSMTP OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The Address of the SMTP server" ::= { ramosOptimaEntry 33 } ramosOptimaMailJpgInline OBJECT-TYPE SYNTAX INTEGER { inline(1), link(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If the jpg for this event is sent as an http link or is included with mail as an attachment" ::= { ramosOptimaEntry 34 } ramosOptimaMailResendInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How often to resend mail or Traps. Enter the number of seconds from 10 to 60. Mail for WARNING and ERROR are resent at this interval. Mail for Normal status are sent once" ::= { ramosOptimaEntry 36 } ramosOptimaMailMaxResend OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of times to resend mail. If set to 0 only send once. The maximum value is 5" ::= { ramosOptimaEntry 37 } ramosOptimaMailLastStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The status of the most recent attempt to send an email" ::= { ramosOptimaEntry 39 } ramosOptimaSupportMailRcpt OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP8L only: E-Mail address of support" ::= { ramosOptimaEntry 40 } ramosOptimaCameraServerTable OBJECT-TYPE SYNTAX SEQUENCE OF RamosOptimaCameraServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "CP8 Only: This table contains the Camera Server features, This allows the ramosOptima to connect to a ramosOptima" ::= { ramosOptimaEntry 42 } ramosOptimaCameraServerEntry OBJECT-TYPE SYNTAX RamosOptimaCameraServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the ramosOptimaCameraServerEntry Table" INDEX { ramosOptimaCameraServerIndex } ::= { ramosOptimaCameraServerTable 1 } RamosOptimaCameraServerEntry ::= SEQUENCE { ramosOptimaCameraServerClientOnline INTEGER, ramosOptimaCameraServerClientGoOnline INTEGER, ramosOptimaCameraServerClientIP IpAddress, ramosOptimaCameraServerClientSetPassword DisplayString, ramosOptimaCameraServerIndex INTEGER, ramosOptimaJavaTimeOut INTEGER, ramosOptimaJpegQualityFactor INTEGER, ramosOptimaCameraDescription DisplayString, ramosOptimaCameraRotate INTEGER, ramosOptimaCameraResolution INTEGER, ramosOptimaPTZRotateRelative DisplayString, ramosOptimaPTZRotateAbsolute DisplayString, ramosOptimaAudioAttachChannel INTEGER, ramosOptimaPTZEnable INTEGER, ramosOptimaPTZBrand INTEGER, ramosOptimaPTZPanTiltUntilEnd INTEGER } ramosOptimaCameraServerClientOnline OBJECT-TYPE SYNTAX INTEGER { online(1), offline(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If this Client is currently online" ::= { ramosOptimaCameraServerEntry 1 } ramosOptimaCameraServerClientGoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put this Client online enter a 1, to take offline enter a 2" ::= { ramosOptimaCameraServerEntry 2 } ramosOptimaCameraServerClientIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the ramosOptima, used to send snmp keep alive messages" ::= { ramosOptimaCameraServerEntry 3 } ramosOptimaCameraServerClientSetPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: The Set Password for the snmp keep alive messages sent to the ramosOptimas" ::= { ramosOptimaCameraServerEntry 4 } ramosOptimaCameraServerIndex OBJECT-TYPE SYNTAX INTEGER (0..9) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Camera table" ::= { ramosOptimaCameraServerEntry 5 } ramosOptimaJavaTimeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Timeout in minutes for Java client" ::= { ramosOptimaCameraServerEntry 6 } ramosOptimaJpegQualityFactor OBJECT-TYPE SYNTAX INTEGER (5..95) ACCESS read-write STATUS mandatory DESCRIPTION "Quality factor of jpeg image" ::= { ramosOptimaCameraServerEntry 7 } ramosOptimaCameraDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A description of camera" ::= { ramosOptimaCameraServerEntry 8 } ramosOptimaCameraRotate OBJECT-TYPE SYNTAX INTEGER { nonRotate(0), rotate(1) } ACCESS read-write STATUS mandatory DESCRIPTION "A Rotate of this camera" ::= { ramosOptimaCameraServerEntry 9 } ramosOptimaCameraResolution OBJECT-TYPE SYNTAX INTEGER { resolution320x240(0), resolution640x480(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Resolution of camera" ::= { ramosOptimaCameraServerEntry 10 } ramosOptimaPTZRotateRelative OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Control PTZ by put Direction and step 'DIR STEP' when direction 0 or 1 is LEFT or RIGH and 2 or 3 is UP or DOWN " ::= { ramosOptimaCameraServerEntry 11 } ramosOptimaPTZRotateAbsolute OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Control PTZ by put position of x and y 'POS_X POS_Y' value of position is 0 to 100" ::= { ramosOptimaCameraServerEntry 12 } ramosOptimaAudioAttachChannel OBJECT-TYPE SYNTAX INTEGER { notAttachAudio(0), attachAudio(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable audio attachment" ::= { ramosOptimaCameraServerEntry 13 } ramosOptimaPTZEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enableInternal(1), enableExternal(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable/Enable Ptz controller" ::= { ramosOptimaCameraServerEntry 14 } ramosOptimaPTZBrand OBJECT-TYPE SYNTAX INTEGER { generalBrand(0), contegBrand(1) } ACCESS read-write STATUS mandatory DESCRIPTION "PTZ Brand" ::= { ramosOptimaCameraServerEntry 15 } ramosOptimaPTZPanTiltUntilEnd OBJECT-TYPE SYNTAX INTEGER { stop(0), right(1), left(2), up(3), down(4), right-up(5), right-down(6), left-up(7), left-down(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Pan or Tilt PTZ until endpoint" ::= { ramosOptimaCameraServerEntry 16 } ramosOptimaTrapMailPollInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: How often the sensor thresholds are tested before sending traps or mail. This can vary from 3 to 15 seconds" ::= { ramosOptimaEntry 50 } ramosOptimaSendTestMail OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Send out an email test message" ::= { ramosOptimaEntry 51 } ramosOptimaLastSystemError OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A text string containing the description of the last system error" ::= { ramosOptimaEntry 52 } ramosOptimaDataCollectionPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of minutes between collections of the data logger. This can vary from 1 to 60 minutes" ::= { ramosOptimaEntry 53 } ramosOptimaMailTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds to wait for a timeout while sending email This can vary from 10 to 30 seconds" ::= { ramosOptimaEntry 54 } ramosOptimaAutoSense OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable Auto-sense feature" ::= { ramosOptimaEntry 55 } ramosOptimaChecksum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SP Only: The Flash Checksum, computed dynamically whenever this object is read" ::= { ramosOptimaEntry 56 } ramosOptimaUsePassword OBJECT-TYPE SYNTAX INTEGER { usePassword(0), doNotUsePassword(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether or not the set and get community are used to check for access rights" ::= { ramosOptimaEntry 57 } ramosOptimaDisplayLogo OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or Disable the display of the logo" ::= { ramosOptimaEntry 59 } ramosOptimaTrapType OBJECT-TYPE SYNTAX INTEGER { specificTypeTrap(1), generalTypeTrap(2), bothTypeTraps(3), statusTypeTraps(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Whether to generate a trap that covers all sensors, a specific trap for each sensor, or both types of traps" ::= { ramosOptimaEntry 60 } ramosOptimaMailCC OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The email address of the CC" ::= { ramosOptimaEntry 61 } ramosOptimaAllowIPChange OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This disables the changing of the IP address. The default is to enable changing the IP address" ::= { ramosOptimaEntry 62 } ramosOptimaTimeOfDay OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The time of day in the format day/month/year hour(1-24):minutes:seconds for example 23/10/02 12:45:06" ::= { ramosOptimaEntry 65 } ramosOptimaEnableSysLog OBJECT-TYPE SYNTAX INTEGER { enableLogToFlash(1), enableLogToNetAndFlash(2), disable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This enables sysLog Messages,including logging to the Net. The Destination IP of the net messages is the same as the source IP of the sender of this command" ::= { ramosOptimaEntry 66 } ramosOptimaReadSysLog OBJECT-TYPE SYNTAX INTEGER { lastMessage(1), allMessages(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Return the sysLog Message in the snmp PDU and if enableLogToNetAndFlash in ramosOptimaEnableSysLog, also send in debug message format, A Write of a 2 will return all of the messages in debug format" ::= { ramosOptimaEntry 67 } ramosOptimaClearSysLog OBJECT-TYPE SYNTAX INTEGER { allMessages(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Delete all entries in the sys log" ::= { ramosOptimaEntry 68 } ramosOptimaSyslogDestIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of the Syslog server. Note: This must be in dotted decimal form" ::= { ramosOptimaEntry 69 } ramosOptimaSyslogPort OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The Port Number of the Syslog server." ::= { ramosOptimaEntry 70 } ramosOptimaSetSyslogMsgPrefix OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: The Prefix message of the Syslog message" ::= { ramosOptimaEntry 71 } -- -- ramosOptimaEntry 72 is reserved for ramosOptimaLanFullDuplex ( SP Only ) -- -- -- ramosOptimaEntry 73 is reserved for ramosOptimaExpectedMicrocodeCRC ( SP Only ) -- -- -- ramosOptimaEntry 74 is reserved for ramosOptimaExpectedMicrocodeLength ( SP Only ) -- -- -- ramosOptimaEntry 75 is reserved for ramosOptimaActualMicrocodeCRC ( SP Only ) -- -- -- ramosOptimaEntry 76 is reserved for ramosOptimaExpectedBootCRC ( SP Only ) -- -- -- ramosOptimaEntry 77 is reserved for ramosOptimaActualBootCRC ( SP Only ) -- -- -- ramosOptimaEntry 78 is reserved for ramosOptimaBootVersion ( SP Only ) -- -- -- ramosOptimaEntry 80 is reserved for ramosOptimaAdcCalibrate -- ramosOptimaTimeZone OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "System time zone" ::= { ramosOptimaEntry 81 } -- -- ramosOptimaEntry 82 is reserved for ramosOptimaExtraDryContactEnable ( SP Only ) -- ramosOptimaMegaVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Version number of mega board" ::= { ramosOptimaEntry 83 } ramosOptimaNtpMode OBJECT-TYPE SYNTAX INTEGER { notUse(0), oneTime(1), onSystemStartUp(2), onceAMounth(3), onceAWeek(4), onceADay(5), onceAnHour(6), continuous(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode to synchronous with ntp server" ::= { ramosOptimaEntry 84 } ramosOptimaNtpServer OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "NTP server which this machine synchronous with" ::= { ramosOptimaEntry 85 } -- -- ramosOptimaEntry 86 is reserved for RamosOptimaModel string which is used internaly (CONTEG). -- ramosOptimaSMTPAuth OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This enables the SMTP authentication" ::= { ramosOptimaEntry 87 } ramosOptimaSMTPLogin OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The username used to login into SMTP server" ::= { ramosOptimaEntry 88 } ramosOptimaSMTPPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The password used to login into SMTP server" ::= { ramosOptimaEntry 89 } ramosOptimaDNSServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the DNS server" ::= { ramosOptimaEntry 90 } ramosOptimaAltWebPort OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The alternative for a port number 80 used to access the web interface" ::= { ramosOptimaEntry 91 } ramosOptimaNumberOfSensorPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of sensor ports(regardless of their current state)" ::= { ramosOptimaEntry 92 } ramosOptimaSendTrapsAlive OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "On or off send keep alive traps." ::= { ramosOptimaEntry 93 } ramosOptimaTrapReIntervalAlive OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Time between each keep alive trap." ::= { ramosOptimaEntry 94 } ramosOptimaUseCamera OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } ACCESS read-write STATUS mandatory DESCRIPTION "On or off camera." ::= { ramosOptimaEntry 95 } ramosOptimaAdcCalibratePort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Calibrate value for analog sensor." ::= { ramosOptimaEntry 96 } -- -- ramosOptimaEntry 97 is reseverd for future using with Linux version (CONTEG). -- ramosOptimaMailSubject OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Email Subject." ::= { ramosOptimaEntry 98 } ramosOptimaSnmpPort OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: Port number used to access snmp" ::= { ramosOptimaEntry 99 } ramosOptimaSnmpTrapPort OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "SP Only: Port number used to access trap snmp" ::= { ramosOptimaEntry 100 } ramosOptimaSnmpIndexingMode OBJECT-TYPE SYNTAX INTEGER { index0(0), index1(1) } ACCESS read-write STATUS mandatory DESCRIPTION "CP8 Only: Snmp table index starting from 0 or 1 " ::= { ramosOptimaEntry 101 } -- -- ramosOptimaEntry 102 is reserved for ramosOptimaSensorSummary -- ramosOptimaNotifyBoot OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP2 Only: Enable Notify on boot up" ::= { ramosOptimaEntry 103 } ramosOptimaDelayNotifyBoot OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP2 Only: Delay time for boot up notify" ::= { ramosOptimaEntry 104 } ramosOptimaSmtpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SMTP Port number used to send email" ::= { ramosOptimaEntry 105 } ramosOptimaReboot OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Reboot SP2/SP8 set to 1" ::= { ramosOptimaEntry 106 } ramosOptimaServerEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable database changed notify feature" ::= { ramosOptimaEntry 107 } ramosOptimaFirmwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Current firmware version" ::= { ramosOptimaEntry 108 } ramosOptimaProductType OBJECT-TYPE SYNTAX INTEGER { ramosOptima2(1), ramosOptima8(2), ramosOptimaLinuxWithoutUSB(3), ramosOptimaLinuxWithUSB(4), ramosUltra(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Product type" ::= { ramosOptimaEntry 109 } ramosOptimaRequestResendTrap OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "SP only: Send immediately all traps by set to 1" ::= { ramosOptimaEntry 110 } -- -- ramosOptimaEntry 111 is reserved for Server Project -- ramosOptimaSeparateEmail OBJECT-TYPE SYNTAX INTEGER { notSeparate(0), separate(1) } ACCESS read-write STATUS mandatory DESCRIPTION "SP only: Separate Email by set 1 for not Separate Email set 0" ::= { ramosOptimaEntry 112 } ramosOptimaMailCustom OBJECT-TYPE SYNTAX INTEGER { normal(0), custom(1) } ACCESS read-write STATUS mandatory DESCRIPTION "SP only: Custom mail is removed 'http://' in the mail footer" ::= { ramosOptimaEntry 113 } ramosOptimaUntidePassword OBJECT-TYPE SYNTAX INTEGER { tidePassword(0), untidePassword(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Use web password as SNMP password" ::= { ramosOptimaEntry 114 } ramosOptimaWebPassword OBJECT IDENTIFIER ::= { ramosOptimaEntry 115 } ramosOptimaWebAdminPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Password Admin for login web and other connections" ::= { ramosOptimaWebPassword 1 } ramosOptimaWebUserPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Password User for login web and other connections" ::= { ramosOptimaWebPassword 2 } ramosOptimaReloadNetwork OBJECT-TYPE SYNTAX INTEGER { reload(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set 1 for reload network seting" ::= { ramosOptimaEntry 116 } ramosOptimaStatusNumber OBJECT IDENTIFIER ::= { ramosOptimaEntry 117 } ramosOptimaStatusNumberNotNormal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of sensor status is Warning, Critical and Sensor Error" ::= { ramosOptimaStatusNumber 1 } ramosOptimaStatusNumberCriticalAndError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of sensor status is Critical and Sensor Error" ::= { ramosOptimaStatusNumber 2 } ramosOptimaStatusNumberError OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of sensor status is Sensor Error" ::= { ramosOptimaStatusNumber 3 } ramosOptimaTypeName OBJECT IDENTIFIER ::= { ramosOptimaEntry 118 } ramosOptimaTypeTemperatureName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 1 } ramosOptimaTypeSHT11HumidityName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 2 } ramosOptimaTypeSHT11TempName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 3 } ramosOptimaType4to20MAName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 4 } ramosOptimaTypeDCvoltageName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 5 } ramosOptimaTypeAirflowName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 6 } ramosOptimaTypeDrycontactInoutName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 7 } ramosOptimaTypeDrycontactInputName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 8 } ramosOptimaTypeMotionName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 9 } ramosOptimaTypeWaterName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 10 } ramosOptimaTypeSecurityName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 11 } ramosOptimaTypeSirenName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 12 } ramosOptimaTypeRelayName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 13 } ramosOptimaTypeACvoltageName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 14 } ramosOptimaTypeADE7763VRMSName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 15 } ramosOptimaTypeADE7763IRMSName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 16 } ramosOptimaTypeADE7763WattName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 17 } ramosOptimaTypeADE7763WatthourName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 18 } ramosOptimaTypePCF8574XRelayName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 19 } ramosOptimaTypeThermocoupleName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 20 } ramosOptimaTypeSmokeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 21 } ramosOptimaTypeXDryName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 22 } ramosOptimaTypeTemperatureArrayName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 23 } ramosOptimaTypeWaterRopeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 24 } ramosOptimaTypeFuelLevelName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 25 } ramosOptimaTypeTankSenderName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 26 } ramosOptimaTypeThurmostatName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 128 } ramosOptimaTypeVirtualName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 129 } ramosOptimaTypeSoundName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 130 } ramosOptimaTypeSoftMotionName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 131 } ramosOptimaTypeNoSignalName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 132 } ramosOptimaTypePowerMeterName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 134 } ramosOptimaTypeSHT11Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 135 } ramosOptimaTypeADE7763Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of Sensor Type Name on web interface" ::= { ramosOptimaTypeName 136 } ramosOptimaProductRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SP only: Revision number" ::= { ramosOptimaEntry 119 } ramosUltra OBJECT IDENTIFIER ::= { conteg 2 } secSummary OBJECT IDENTIFIER ::= { ramosUltra 1 } secDevice OBJECT IDENTIFIER ::= { ramosUltra 2 } deviceTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property for every plugged-in device." ::= { secDevice 1 } deviceEntry OBJECT-TYPE SYNTAX DeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the deviceEntry Table" INDEX { deviceIndex } ::= { deviceTable 1 } DeviceEntry ::= SEQUENCE { deviceIndex INTEGER, deviceDescription DisplayString, deviceType INTEGER, deviceInfo DisplayString, deviceStatus INTEGER } deviceIndex OBJECT-TYPE SYNTAX INTEGER (1..184549375) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the device table" ::= { deviceEntry 1 } deviceDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this device" ::= { deviceEntry 2 } deviceType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "..." ::= { deviceEntry 3 } deviceInfo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A information of this device" ::= { deviceEntry 4 } deviceStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "..." ::= { deviceEntry 5 } deviceIntelligentTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceIntelligentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property for every plugged-in device." ::= { secDevice 2 } deviceIntelligentEntry OBJECT-TYPE SYNTAX DeviceIntelligentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the deviceEntry Table" INDEX { deviceIntelligentIndex } ::= { deviceIntelligentTable 1 } DeviceIntelligentEntry ::= SEQUENCE { deviceIntelligentIndex INTEGER, deviceIntelligentDescription DisplayString, deviceIntelligentInfo DisplayString, deviceIntelligentStatus INTEGER, sensorIntelligentTypeSelected INTEGER, sensorIntelligentPort1GoOnline INTEGER, sensorIntelligentPort2GoOnline INTEGER, sensorIntelligentPort3GoOnline INTEGER, sensorIntelligentPort4GoOnline INTEGER, sensorIntelligentPort5GoOnline INTEGER, sensorIntelligentPort6GoOnline INTEGER, sensorIntelligentPort7GoOnline INTEGER, sensorIntelligentPort8GoOnline INTEGER } deviceIntelligentIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the deviceIntelligent table" ::= { deviceIntelligentEntry 1 } deviceIntelligentDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this device" ::= { deviceIntelligentEntry 2 } deviceIntelligentInfo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A information of this device" ::= { deviceIntelligentEntry 4 } deviceIntelligentStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 5 } sensorIntelligentTypeSelected OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 6 } sensorIntelligentPort1GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 100 } sensorIntelligentPort2GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 101 } sensorIntelligentPort3GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 102 } sensorIntelligentPort4GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 103 } sensorIntelligentPort5GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 104 } sensorIntelligentPort6GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 105 } sensorIntelligentPort7GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 106 } sensorIntelligentPort8GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceIntelligentEntry 107 } deviceDryContactTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceDryContactEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property for every plugged-in device." ::= { secDevice 3 } deviceDryContactEntry OBJECT-TYPE SYNTAX DeviceDryContactEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the deviceEntry Table" INDEX { deviceDryContactIndex } ::= { deviceDryContactTable 1 } DeviceDryContactEntry ::= SEQUENCE { deviceDryContactIndex INTEGER, deviceDryContactDescription DisplayString, deviceDryContactInfo DisplayString, deviceDryContactStatus INTEGER, sensorDryContactPort1GoOnline INTEGER, sensorDryContactPort2GoOnline INTEGER, sensorDryContactPort3GoOnline INTEGER, sensorDryContactPort4GoOnline INTEGER, sensorDryContactPort5GoOnline INTEGER, sensorDryContactPort6GoOnline INTEGER, sensorDryContactPort7GoOnline INTEGER, sensorDryContactPort8GoOnline INTEGER, sensorDryContactPort9GoOnline INTEGER, sensorDryContactPort10GoOnline INTEGER, sensorDryContactPort11GoOnline INTEGER, sensorDryContactPort12GoOnline INTEGER, sensorDryContactPort13GoOnline INTEGER, sensorDryContactPort14GoOnline INTEGER, sensorDryContactPort15GoOnline INTEGER, sensorDryContactPort16GoOnline INTEGER } deviceDryContactIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the deviceDryContact table" ::= { deviceDryContactEntry 1 } deviceDryContactDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this device" ::= { deviceDryContactEntry 2 } deviceDryContactInfo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A information of this device" ::= { deviceDryContactEntry 4 } deviceDryContactStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 5 } sensorDryContactPort1GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 100 } sensorDryContactPort2GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 101 } sensorDryContactPort3GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 102 } sensorDryContactPort4GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 103 } sensorDryContactPort5GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 104 } sensorDryContactPort6GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 105 } sensorDryContactPort7GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 106 } sensorDryContactPort8GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 107 } sensorDryContactPort9GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 108 } sensorDryContactPort10GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 109 } sensorDryContactPort11GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 110 } sensorDryContactPort12GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 111 } sensorDryContactPort13GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 112 } sensorDryContactPort14GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 113 } sensorDryContactPort15GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 114 } sensorDryContactPort16GoOnline OBJECT-TYPE SYNTAX INTEGER { goOnline(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "..." ::= { deviceDryContactEntry 115 } secSensor OBJECT IDENTIFIER ::= { ramosUltra 3 } sensorTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 1 } --/* Begin of sensorEntry */ sensorEntry OBJECT-TYPE SYNTAX SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTable Table" INDEX { sensorIndex } ::= { sensorTable 1 } SensorEntry ::= SEQUENCE { sensorIndex INTEGER, sensorDescription DisplayString, sensorType INTEGER, sensorValue INTEGER, sensorUnit DisplayString, sensorStatus INTEGER, sensorGoOffline INTEGER, sensorPort INTEGER, sensorSubPort INTEGER, sensorDeviceIndex INTEGER, sensorDisplayStyle INTEGER, sensorHighCriticalDescription DisplayString, sensorLowCriticalDescription DisplayString, sensorNormalDescription DisplayString, sensorLowWarningDescription DisplayString, sensorHighWarningDescription DisplayString, sensorErrorDescription DisplayString, sensorOnDescription DisplayString, sensorOffDescription DisplayString, sensorHighCriticalColor INTEGER, sensorLowCriticalColor INTEGER, sensorNormalColor INTEGER, sensorLowWarningColor INTEGER, sensorHighWarningColor INTEGER, sensorErrorColor INTEGER, sensorOnColor INTEGER, sensorOffColor INTEGER } sensorIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensorEntry 1 } sensorDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorEntry 2 } sensorType OBJECT-TYPE SYNTAX INTEGER { temperature(1), humidity(2), temperature2(3), four-20mA(4), dcvoltage(5), airflow(6), io(7), drycontact(8), motion(9), water(10), security(11), siren(12), relay(13), acvoltage(14), vrms(15), irms(16), watt(17), watthour(18), xrelay(19), thermocouple(20), smoke(21), drycontact-array(22), temperature-array(23), thermostat(128), virtual(129), sound(130), softmotion(131), camera-dummy(132), board-state(133), nosignal(224), test(255) } ACCESS read-only STATUS mandatory DESCRIPTION "Enter the type of this Sensor" ::= { sensorEntry 3 } sensorValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value in this sensor" ::= { sensorEntry 4 } sensorUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The unit string" ::= { sensorEntry 5 } sensorStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this sensor" ::= { sensorEntry 6 } sensorGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorEntry 8 } sensorPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorEntry 35 } sensorSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorEntry 36 } sensorDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorEntry 37 } sensorDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Temperature display style" ::= { sensorEntry 45 } sensorHighCriticalDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorEntry 46 } sensorLowCriticalDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorEntry 47 } sensorNormalDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorEntry 48 } sensorLowWarningDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorEntry 49 } sensorHighWarningDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorEntry 50 } sensorErrorDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorEntry 51 } sensorOnDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A On Description of this sensor" ::= { sensorEntry 52 } sensorOffDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Off Description of this sensor" ::= { sensorEntry 53 } sensorHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorEntry 54 } sensorLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorEntry 55 } sensorNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorEntry 56 } sensorLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorEntry 57 } sensorHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorEntry 58 } sensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorEntry 59 } sensorOnColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A On Color of this sensor" ::= { sensorEntry 60 } sensorOffColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Off Color of this sensor" ::= { sensorEntry 61 } --/* End of sensorEntry */ --/* Begin of sensorTemperatureEntry */ sensorTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorTemperatureEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every Temperature sensor." ::= { secSensor 2 } sensorTemperatureEntry OBJECT-TYPE SYNTAX SensorTemperatureEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorTemperatureIndex } ::= { sensorTemperatureTable 1 } SensorTemperatureEntry ::= SEQUENCE { sensorTemperatureIndex INTEGER, sensorTemperatureDescription DisplayString, sensorTemperatureType INTEGER, sensorTemperatureDegree INTEGER, sensorTemperatureUnit DisplayString, sensorTemperatureStatus INTEGER, sensorTemperatureGoOffline INTEGER, sensorTemperatureLowCritical INTEGER, sensorTemperatureLowWarning INTEGER, sensorTemperatureHighWarning INTEGER, sensorTemperatureHighCritical INTEGER, sensorTemperatureRearm INTEGER, sensorTemperatureDelayError INTEGER, sensorTemperatureDelayNormal INTEGER, sensorTemperatureDelayLowCritical INTEGER, sensorTemperatureDelayLowWarning INTEGER, sensorTemperatureDelayHighWarning INTEGER, sensorTemperatureDelayHighCritical INTEGER, sensorTemperatureRaw INTEGER, sensorTemperatureOffset INTEGER, sensorTemperaturePort INTEGER, sensorTemperatureSubPort INTEGER, sensorTemperatureDeviceIndex INTEGER, sensorTemperatureDisplayStyle INTEGER, sensorTemperatureHighCriticalDesc DisplayString, sensorTemperatureLowCriticalDesc DisplayString, sensorTemperatureNormalDesc DisplayString, sensorTemperatureLowWarningDesc DisplayString, sensorTemperatureHighWarningDesc DisplayString, sensorTemperatureSensorErrorDesc DisplayString, sensorTemperatureHighCriticalColor INTEGER, sensorTemperatureLowCriticalColor INTEGER, sensorTemperatureNormalColor INTEGER, sensorTemperatureLowWarningColor INTEGER, sensorTemperatureHighWarningColor INTEGER, sensorTemperatureSensorErrorColor INTEGER } sensorTemperatureIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensorTemperatureEntry 1 } sensorTemperatureDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorTemperatureEntry 2 } sensorTemperatureType OBJECT-TYPE SYNTAX INTEGER { temperature(1), dualsensor(3), thermocouple(20) } ACCESS read-only STATUS mandatory DESCRIPTION "Enter the type of this Sensor" ::= { sensorTemperatureEntry 3 } sensorTemperatureDegree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The degrees in this sensor" ::= { sensorTemperatureEntry 4 } sensorTemperatureUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The unit string" ::= { sensorTemperatureEntry 5 } sensorTemperatureStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorTemperatureEntry 6 } sensorTemperatureGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorTemperatureEntry 8 } sensorTemperatureLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { sensorTemperatureEntry 9 } sensorTemperatureLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { sensorTemperatureEntry 10 } sensorTemperatureHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { sensorTemperatureEntry 11 } sensorTemperatureHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { sensorTemperatureEntry 12 } sensorTemperatureRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorTemperatureEntry 13 } sensorTemperatureDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorTemperatureEntry 14 } sensorTemperatureDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorTemperatureEntry 15 } sensorTemperatureDelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensorTemperatureEntry 16 } sensorTemperatureDelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensorTemperatureEntry 17 } sensorTemperatureDelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensorTemperatureEntry 18 } sensorTemperatureDelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensorTemperatureEntry 19 } sensorTemperatureRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The raw degree data from the temperature sensor, slightly higher resolution" ::= { sensorTemperatureEntry 20 } sensorTemperatureOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Temperature Offset reading" ::= { sensorTemperatureEntry 21 } sensorTemperaturePort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorTemperatureEntry 35 } sensorTemperatureSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorTemperatureEntry 36 } sensorTemperatureDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorTemperatureEntry 37 } sensorTemperatureDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Temperature display style" ::= { sensorTemperatureEntry 45 } sensorTemperatureHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorTemperatureEntry 46 } sensorTemperatureLowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorTemperatureEntry 47 } sensorTemperatureNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorTemperatureEntry 48 } sensorTemperatureLowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorTemperatureEntry 49 } sensorTemperatureHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorTemperatureEntry 50 } sensorTemperatureSensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorTemperatureEntry 51 } sensorTemperatureHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorTemperatureEntry 54 } sensorTemperatureLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorTemperatureEntry 55 } sensorTemperatureNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorTemperatureEntry 56 } sensorTemperatureLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorTemperatureEntry 57 } sensorTemperatureHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorTemperatureEntry 58 } sensorTemperatureSensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorTemperatureEntry 59 } --/* End of sensorTemperatureEntry */ --/* Begin of sensorHumidityEntry */ sensorHumidityTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorHumidityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 3 } sensorHumidityEntry OBJECT-TYPE SYNTAX SensorHumidityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorHumidityIndex } ::= { sensorHumidityTable 1 } SensorHumidityEntry ::= SEQUENCE { sensorHumidityIndex INTEGER, sensorHumidityDescription DisplayString, sensorHumidityPercent INTEGER, sensorHumidityUnit DisplayString, sensorHumidityStatus INTEGER, sensorHumidityGoOffline INTEGER, sensorHumidityLowCritical INTEGER, sensorHumidityLowWarning INTEGER, sensorHumidityHighWarning INTEGER, sensorHumidityHighCritical INTEGER, sensorHumidityRearm INTEGER, sensorHumidityDelayError INTEGER, sensorHumidityDelayNormal INTEGER, sensorHumidityDelayLowCritical INTEGER, sensorHumidityDelayLowWarning INTEGER, sensorHumidityDelayHighWarning INTEGER, sensorHumidityDelayHighCritical INTEGER, sensorHumidityRaw INTEGER, sensorHumidityOffset INTEGER, sensorHumidityPort INTEGER, sensorHumiditySubPort INTEGER, sensorHumidityDeviceIndex INTEGER, sensorHumidityDisplayStyle INTEGER, sensorHumidityHighCriticalDesc DisplayString, sensorHumidityLowCriticalDesc DisplayString, sensorHumidityNormalDesc DisplayString, sensorHumidityLowWarningDesc DisplayString, sensorHumidityHighWarningDesc DisplayString, sensorHumiditySensorErrorDesc DisplayString, sensorHumidityHighCriticalColor INTEGER, sensorHumidityLowCriticalColor INTEGER, sensorHumidityNormalColor INTEGER, sensorHumidityLowWarningColor INTEGER, sensorHumidityHighWarningColor INTEGER, sensorHumiditySensorErrorColor INTEGER } sensorHumidityIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensorHumidityEntry 1 } sensorHumidityDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorHumidityEntry 2 } sensorHumidityPercent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The relative humidity percentage measured by this sensor" ::= { sensorHumidityEntry 4 } sensorHumidityUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The unit string" ::= { sensorHumidityEntry 5 } sensorHumidityStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorHumidityEntry 6 } sensorHumidityGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorHumidityEntry 8 } sensorHumidityLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { sensorHumidityEntry 9 } sensorHumidityLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { sensorHumidityEntry 10 } sensorHumidityHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { sensorHumidityEntry 11 } sensorHumidityHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { sensorHumidityEntry 12 } sensorHumidityRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorHumidityEntry 13 } sensorHumidityDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorHumidityEntry 14 } sensorHumidityDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorHumidityEntry 15 } sensorHumidityDelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensorHumidityEntry 16 } sensorHumidityDelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensorHumidityEntry 17 } sensorHumidityDelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensorHumidityEntry 18 } sensorHumidityDelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensorHumidityEntry 19 } sensorHumidityRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { sensorHumidityEntry 20 } sensorHumidityOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Humidity Offset reading" ::= { sensorHumidityEntry 21 } sensorHumidityPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorHumidityEntry 35 } sensorHumiditySubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorHumidityEntry 36 } sensorHumidityDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorHumidityEntry 37 } sensorHumidityDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Humidity display style" ::= { sensorHumidityEntry 45 } sensorHumidityHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorHumidityEntry 46 } sensorHumidityLowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorHumidityEntry 47 } sensorHumidityNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorHumidityEntry 48 } sensorHumidityLowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorHumidityEntry 49 } sensorHumidityHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorHumidityEntry 50 } sensorHumiditySensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorHumidityEntry 51 } sensorHumidityHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorHumidityEntry 54 } sensorHumidityLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorHumidityEntry 55 } sensorHumidityNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorHumidityEntry 56 } sensorHumidityLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorHumidityEntry 57 } sensorHumidityHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorHumidityEntry 58 } sensorHumiditySensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorHumidityEntry 59 } --/* End of sensorHumidityEntry */ --/* Begin of sensorDryContactEntry */ sensorDryContactTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorDryContactEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 4 } sensorDryContactEntry OBJECT-TYPE SYNTAX SensorDryContactEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorDryContactIndex } ::= { sensorDryContactTable 1 } SensorDryContactEntry ::= SEQUENCE { sensorDryContactIndex INTEGER, sensorDryContactDescription DisplayString, sensorDryContactType INTEGER, sensorDryContactStatus INTEGER, sensorDryContactGoOffline INTEGER, sensorDryContactDirection INTEGER, sensorDryContactNormalState INTEGER, sensorDryContactControlMode INTEGER, sensorDryContactOutputManualCycleTime INTEGER, sensorDryContactOutputManualAction INTEGER, sensorDryContactPort INTEGER, sensorDryContactSubPort INTEGER, sensorDryContactDeviceIndex INTEGER, sensorDryContactCriticalDesc DisplayString, sensorDryContactNormalDesc DisplayString, sensorDryContactOnDesc DisplayString, sensorDryContactOffDesc DisplayString, sensorDryContactCriticalColor INTEGER, sensorDryContactNormalColor INTEGER, sensorDryContactOnColor INTEGER, sensorDryContactOffColor INTEGER } sensorDryContactIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorDryContactEntry 1 } sensorDryContactDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorDryContactEntry 2 } sensorDryContactType OBJECT-TYPE SYNTAX INTEGER { drycontact-inout(7), drycontact-input(8), drycontact-array(22) } ACCESS read-only STATUS mandatory DESCRIPTION "Enter the type of this Sensor" ::= { sensorDryContactEntry 3 } sensorDryContactStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), outputLow(8), outputHigh(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorDryContactEntry 6 } sensorDryContactGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorDryContactEntry 8 } sensorDryContactDirection OBJECT-TYPE SYNTAX INTEGER { input(0), output(1) } ACCESS read-write STATUS mandatory DESCRIPTION "To set a switch to input enter 0. To set a switch to output enter 1" ::= { sensorDryContactEntry 22 } sensorDryContactNormalState OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The normal state of an input switch. If an input switch is in this state it is normal, else it is critical. An open switch senses +5 volts. A closed switch senses 0 volts." ::= { sensorDryContactEntry 23 } sensorDryContactControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), sensor-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a sensor output." ::= { sensorDryContactEntry 24 } sensorDryContactOutputManualCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Toggle period in seconds for Manual Cycle action." ::= { sensorDryContactEntry 25 } sensorDryContactOutputManualAction OBJECT-TYPE SYNTAX INTEGER { low(0), high(1), cycle-Low-High-Low(2), cycle-High-Low-High(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the sensor output manualy" ::= { sensorDryContactEntry 26 } sensorDryContactPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorDryContactEntry 35 } sensorDryContactSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorDryContactEntry 36 } sensorDryContactDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorDryContactEntry 37 } sensorDryContactCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Description of this sensor" ::= { sensorDryContactEntry 46 } sensorDryContactNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorDryContactEntry 48 } sensorDryContactOnDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A On Description of this sensor" ::= { sensorDryContactEntry 52 } sensorDryContactOffDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Off Description of this sensor" ::= { sensorDryContactEntry 53 } sensorDryContactCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Color of this sensor" ::= { sensorDryContactEntry 54 } sensorDryContactNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorDryContactEntry 56 } sensorDryContactOnColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A On Color of this sensor" ::= { sensorDryContactEntry 60 } sensorDryContactOffColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Off Color of this sensor" ::= { sensorDryContactEntry 61 } --/* End of sensorDryContactEntry */ --/* Begin of sensor4to20mAEntry */ sensor4to20mATable OBJECT-TYPE SYNTAX SEQUENCE OF Sensor4to20mAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 5 } sensor4to20mAEntry OBJECT-TYPE SYNTAX Sensor4to20mAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensor4to20mAIndex } ::= { sensor4to20mATable 1 } Sensor4to20mAEntry ::= SEQUENCE { sensor4to20mAIndex INTEGER, sensor4to20mADescription DisplayString, sensor4to20mAValue INTEGER, sensor4to20mAUnit DisplayString, sensor4to20mAStatus INTEGER, sensor4to20mAGoOffline INTEGER, sensor4to20mALowCritical INTEGER, sensor4to20mALowWarning INTEGER, sensor4to20mAHighWarning INTEGER, sensor4to20mAHighCritical INTEGER, sensor4to20mARearm INTEGER, sensor4to20mADelayError INTEGER, sensor4to20mADelayNormal INTEGER, sensor4to20mADelayLowCritical INTEGER, sensor4to20mADelayLowWarning INTEGER, sensor4to20mADelayHighWarning INTEGER, sensor4to20mADelayHighCritical INTEGER, sensor4to20mARaw INTEGER, sensor4to20mAOffset INTEGER, sensor4to20mAAmountMaxVoltage INTEGER, sensor4to20mAAmountBaseVoltage INTEGER, sensor4to20mAPort INTEGER, sensor4to20mASubPort INTEGER, sensor4to20mADeviceIndex INTEGER, sensor4to20mAMaxVoltage INTEGER, sensor4to20mABaseVoltage INTEGER, sensor4to20mADisplayStyle INTEGER, sensor4to20mAHighCriticalDesc DisplayString, sensor4to20mALowCriticalDesc DisplayString, sensor4to20mANormalDesc DisplayString, sensor4to20mALowWarningDesc DisplayString, sensor4to20mAHighWarningDesc DisplayString, sensor4to20mASensorErrorDesc DisplayString, sensor4to20mAHighCriticalColor INTEGER, sensor4to20mALowCriticalColor INTEGER, sensor4to20mANormalColor INTEGER, sensor4to20mALowWarningColor INTEGER, sensor4to20mAHighWarningColor INTEGER, sensor4to20mASensorErrorColor INTEGER } sensor4to20mAIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensor4to20mAEntry 1 } sensor4to20mADescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensor4to20mAEntry 2 } sensor4to20mAValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The reading value in this sensor" ::= { sensor4to20mAEntry 4 } sensor4to20mAUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The unit string" ::= { sensor4to20mAEntry 5 } sensor4to20mAStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensor4to20mAEntry 6 } sensor4to20mAGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensor4to20mAEntry 8 } sensor4to20mALowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { sensor4to20mAEntry 9 } sensor4to20mALowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { sensor4to20mAEntry 10 } sensor4to20mAHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { sensor4to20mAEntry 11 } sensor4to20mAHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { sensor4to20mAEntry 12 } sensor4to20mARearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensor4to20mAEntry 13 } sensor4to20mADelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensor4to20mAEntry 14 } sensor4to20mADelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensor4to20mAEntry 15 } sensor4to20mADelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensor4to20mAEntry 16 } sensor4to20mADelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensor4to20mAEntry 17 } sensor4to20mADelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensor4to20mAEntry 18 } sensor4to20mADelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensor4to20mAEntry 19 } sensor4to20mARaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { sensor4to20mAEntry 20 } sensor4to20mAOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "4to20mA Offset reading" ::= { sensor4to20mAEntry 21 } sensor4to20mAAmountMaxVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum scale of 4to20mA conversion." ::= { sensor4to20mAEntry 33 } sensor4to20mAAmountBaseVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The base scale of 4to20mA conversion." ::= { sensor4to20mAEntry 34 } sensor4to20mAPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensor4to20mAEntry 35 } sensor4to20mASubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensor4to20mAEntry 36 } sensor4to20mADeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensor4to20mAEntry 37 } sensor4to20mAMaxVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The max range for use in conversion." ::= { sensor4to20mAEntry 43 } sensor4to20mABaseVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The base range for use in conversion." ::= { sensor4to20mAEntry 44 } sensor4to20mADisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "4to20mA display style" ::= { sensor4to20mAEntry 45 } sensor4to20mAHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensor4to20mAEntry 46 } sensor4to20mALowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensor4to20mAEntry 47 } sensor4to20mANormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensor4to20mAEntry 48 } sensor4to20mALowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensor4to20mAEntry 49 } sensor4to20mAHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensor4to20mAEntry 50 } sensor4to20mASensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensor4to20mAEntry 51 } sensor4to20mAHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensor4to20mAEntry 54 } sensor4to20mALowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensor4to20mAEntry 55 } sensor4to20mANormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensor4to20mAEntry 56 } sensor4to20mALowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensor4to20mAEntry 57 } sensor4to20mAHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensor4to20mAEntry 58 } sensor4to20mASensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensor4to20mAEntry 59 } --/* End of sensor4to20mAEntry */ --/* Begin of sensorDCvoltageEntry */ sensorDCvoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorDCvoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 6 } sensorDCvoltageEntry OBJECT-TYPE SYNTAX SensorDCvoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorDCvoltageIndex } ::= { sensorDCvoltageTable 1 } SensorDCvoltageEntry ::= SEQUENCE { sensorDCvoltageIndex INTEGER, sensorDCvoltageDescription DisplayString, sensorDCvoltageValue INTEGER, sensorDCvoltageUnit DisplayString, sensorDCvoltageStatus INTEGER, sensorDCvoltageGoOffline INTEGER, sensorDCvoltageLowCritical INTEGER, sensorDCvoltageLowWarning INTEGER, sensorDCvoltageHighWarning INTEGER, sensorDCvoltageHighCritical INTEGER, sensorDCvoltageRearm INTEGER, sensorDCvoltageDelayError INTEGER, sensorDCvoltageDelayNormal INTEGER, sensorDCvoltageDelayLowCritical INTEGER, sensorDCvoltageDelayLowWarning INTEGER, sensorDCvoltageDelayHighWarning INTEGER, sensorDCvoltageDelayHighCritical INTEGER, sensorDCvoltageRaw INTEGER, sensorDCvoltageOffset INTEGER, sensorDCvoltageJumper INTEGER, sensorDCvoltageAmountMaxVoltage INTEGER, sensorDCvoltageAmountBaseVoltage INTEGER, sensorDCvoltagePort INTEGER, sensorDCvoltageSubPort INTEGER, sensorDCvoltageDeviceIndex INTEGER, sensorDCvoltageMaxVoltage INTEGER, sensorDCvoltageBaseVoltage INTEGER, sensorDCvoltageDisplayStyle INTEGER, sensorDCvoltageHighCriticalDesc DisplayString, sensorDCvoltageLowCriticalDesc DisplayString, sensorDCvoltageNormalDesc DisplayString, sensorDCvoltageLowWarningDesc DisplayString, sensorDCvoltageHighWarningDesc DisplayString, sensorDCvoltageSensorErrorDesc DisplayString, sensorDCvoltageHighCriticalColor INTEGER, sensorDCvoltageLowCriticalColor INTEGER, sensorDCvoltageNormalColor INTEGER, sensorDCvoltageLowWarningColor INTEGER, sensorDCvoltageHighWarningColor INTEGER, sensorDCvoltageSensorErrorColor INTEGER } sensorDCvoltageIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensorDCvoltageEntry 1 } sensorDCvoltageDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorDCvoltageEntry 2 } sensorDCvoltageValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The reading value in this sensor" ::= { sensorDCvoltageEntry 4 } sensorDCvoltageUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The unit string" ::= { sensorDCvoltageEntry 5 } sensorDCvoltageStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorDCvoltageEntry 6 } sensorDCvoltageGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorDCvoltageEntry 8 } sensorDCvoltageLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { sensorDCvoltageEntry 9 } sensorDCvoltageLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { sensorDCvoltageEntry 10 } sensorDCvoltageHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { sensorDCvoltageEntry 11 } sensorDCvoltageHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { sensorDCvoltageEntry 12 } sensorDCvoltageRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorDCvoltageEntry 13 } sensorDCvoltageDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorDCvoltageEntry 14 } sensorDCvoltageDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorDCvoltageEntry 15 } sensorDCvoltageDelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensorDCvoltageEntry 16 } sensorDCvoltageDelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensorDCvoltageEntry 17 } sensorDCvoltageDelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensorDCvoltageEntry 18 } sensorDCvoltageDelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensorDCvoltageEntry 19 } sensorDCvoltageRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { sensorDCvoltageEntry 20 } sensorDCvoltageOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "DC voltage Offset reading" ::= { sensorDCvoltageEntry 21 } sensorDCvoltageJumper OBJECT-TYPE SYNTAX INTEGER { jumperAt-60(-600), jumperAt-40(-400), jumperAt-30(-300), jumperAt-20(-200), jumperAt-10(-100), jumperAt10(100), jumperAt20(200), jumperAt30(300), jumperAt40(400), jumperAt60(600) } ACCESS read-write STATUS mandatory DESCRIPTION "Selected voltage scale (jumper 0) in DC voltage conversion." ::= { sensorDCvoltageEntry 32 } sensorDCvoltageAmountMaxVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum scale of DC voltage conversion." ::= { sensorDCvoltageEntry 33 } sensorDCvoltageAmountBaseVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The base scale of DC voltage conversion." ::= { sensorDCvoltageEntry 34 } sensorDCvoltagePort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorDCvoltageEntry 35 } sensorDCvoltageSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorDCvoltageEntry 36 } sensorDCvoltageDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorDCvoltageEntry 37 } sensorDCvoltageMaxVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The max voltage range for use in conversion." ::= { sensorDCvoltageEntry 43 } sensorDCvoltageBaseVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The base voltage range for use in conversion." ::= { sensorDCvoltageEntry 44 } sensorDCvoltageDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "DCVoltage display style" ::= { sensorDCvoltageEntry 45 } sensorDCvoltageHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorDCvoltageEntry 46 } sensorDCvoltageLowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorDCvoltageEntry 47 } sensorDCvoltageNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorDCvoltageEntry 48 } sensorDCvoltageLowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorDCvoltageEntry 49 } sensorDCvoltageHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorDCvoltageEntry 50 } sensorDCvoltageSensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorDCvoltageEntry 51 } sensorDCvoltageHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorDCvoltageEntry 54 } sensorDCvoltageLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorDCvoltageEntry 55 } sensorDCvoltageNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorDCvoltageEntry 56 } sensorDCvoltageLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorDCvoltageEntry 57 } sensorDCvoltageHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorDCvoltageEntry 58 } sensorDCvoltageSensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorDCvoltageEntry 59 } --/* End of sensorDCvoltageEntry */ --/* Begin of sensorAirflowEntry */ sensorAirflowTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorAirflowEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 7 } sensorAirflowEntry OBJECT-TYPE SYNTAX SensorAirflowEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorAirflowIndex } ::= { sensorAirflowTable 1 } SensorAirflowEntry ::= SEQUENCE { sensorAirflowIndex INTEGER, sensorAirflowDescription DisplayString, sensorAirflowValue INTEGER, sensorAirflowStatus INTEGER, sensorAirflowGoOffline INTEGER, sensorAirflowLowCritical INTEGER, sensorAirflowLowWarning INTEGER, sensorAirflowHighWarning INTEGER, sensorAirflowHighCritical INTEGER, sensorAirflowRearm INTEGER, sensorAirflowDelayError INTEGER, sensorAirflowDelayNormal INTEGER, sensorAirflowDelayLowCritical INTEGER, sensorAirflowDelayLowWarning INTEGER, sensorAirflowDelayHighWarning INTEGER, sensorAirflowDelayHighCritical INTEGER, sensorAirflowRaw INTEGER, sensorAirflowPort INTEGER, sensorAirflowSubPort INTEGER, sensorAirflowDeviceIndex INTEGER, sensorAirflowDisplayStyle INTEGER, sensorAirflowHighCriticalDesc DisplayString, sensorAirflowLowCriticalDesc DisplayString, sensorAirflowNormalDesc DisplayString, sensorAirflowLowWarningDesc DisplayString, sensorAirflowHighWarningDesc DisplayString, sensorAirflowSensorErrorDesc DisplayString, sensorAirflowHighCriticalColor INTEGER, sensorAirflowLowCriticalColor INTEGER, sensorAirflowNormalColor INTEGER, sensorAirflowLowWarningColor INTEGER, sensorAirflowHighWarningColor INTEGER, sensorAirflowSensorErrorColor INTEGER } sensorAirflowIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorAirflowEntry 1 } sensorAirflowDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorAirflowEntry 2 } sensorAirflowValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The reading value in this sensor" ::= { sensorAirflowEntry 4 } sensorAirflowStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorAirflowEntry 6 } sensorAirflowGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorAirflowEntry 8 } sensorAirflowLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { sensorAirflowEntry 9 } sensorAirflowLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { sensorAirflowEntry 10 } sensorAirflowHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { sensorAirflowEntry 11 } sensorAirflowHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { sensorAirflowEntry 12 } sensorAirflowRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorAirflowEntry 13 } sensorAirflowDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorAirflowEntry 14 } sensorAirflowDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorAirflowEntry 15 } sensorAirflowDelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensorAirflowEntry 16 } sensorAirflowDelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensorAirflowEntry 17 } sensorAirflowDelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensorAirflowEntry 18 } sensorAirflowDelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensorAirflowEntry 19 } sensorAirflowRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage" ::= { sensorAirflowEntry 20 } sensorAirflowPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorAirflowEntry 35 } sensorAirflowSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorAirflowEntry 36 } sensorAirflowDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorAirflowEntry 37 } sensorAirflowDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Airflow display style" ::= { sensorAirflowEntry 45 } sensorAirflowHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorAirflowEntry 46 } sensorAirflowLowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorAirflowEntry 47 } sensorAirflowNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorAirflowEntry 48 } sensorAirflowLowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorAirflowEntry 49 } sensorAirflowHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorAirflowEntry 50 } sensorAirflowSensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorAirflowEntry 51 } sensorAirflowHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorAirflowEntry 54 } sensorAirflowLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorAirflowEntry 55 } sensorAirflowNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorAirflowEntry 56 } sensorAirflowLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorAirflowEntry 57 } sensorAirflowHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorAirflowEntry 58 } sensorAirflowSensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorAirflowEntry 59 } --/* End of sensorAirflowEntry */ --/* Begin of sensorMotionEntry */ sensorMotionTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorMotionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 8 } sensorMotionEntry OBJECT-TYPE SYNTAX SensorMotionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorMotionIndex } ::= { sensorMotionTable 1 } SensorMotionEntry ::= SEQUENCE { sensorMotionIndex INTEGER, sensorMotionDescription DisplayString, sensorMotionStatus INTEGER, sensorMotionGoOffline INTEGER, sensorMotionPort INTEGER, sensorMotionSubPort INTEGER, sensorMotionDeviceIndex INTEGER, sensorMotionCriticalDesc DisplayString, sensorMotionNormalDesc DisplayString, sensorMotionCriticalColor INTEGER, sensorMotionNormalColor INTEGER } sensorMotionIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorMotionEntry 1 } sensorMotionDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorMotionEntry 2 } sensorMotionStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorMotionEntry 6 } sensorMotionGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorMotionEntry 8 } sensorMotionPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorMotionEntry 35 } sensorMotionSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorMotionEntry 36 } sensorMotionDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorMotionEntry 37 } sensorMotionCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Description of this sensor" ::= { sensorMotionEntry 46 } sensorMotionNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorMotionEntry 48 } sensorMotionCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Color of this sensor" ::= { sensorMotionEntry 54 } sensorMotionNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorMotionEntry 56 } --/* End of sensorMotionEntry */ --/* Begin of sensorWaterEntry */ sensorWaterTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorWaterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 9 } sensorWaterEntry OBJECT-TYPE SYNTAX SensorWaterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorWaterIndex } ::= { sensorWaterTable 1 } SensorWaterEntry ::= SEQUENCE { sensorWaterIndex INTEGER, sensorWaterDescription DisplayString, sensorWaterStatus INTEGER, sensorWaterGoOffline INTEGER, sensorWaterPort INTEGER, sensorWaterSubPort INTEGER, sensorWaterDeviceIndex INTEGER, sensorWaterCriticalDesc DisplayString, sensorWaterNormalDesc DisplayString, sensorWaterCriticalColor INTEGER, sensorWaterNormalColor INTEGER } sensorWaterIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorWaterEntry 1 } sensorWaterDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorWaterEntry 2 } sensorWaterStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorWaterEntry 6 } sensorWaterGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorWaterEntry 8 } sensorWaterPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorWaterEntry 35 } sensorWaterSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorWaterEntry 36 } sensorWaterDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorWaterEntry 37 } sensorWaterCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Description of this sensor" ::= { sensorWaterEntry 46 } sensorWaterNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorWaterEntry 48 } sensorWaterCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Color of this sensor" ::= { sensorWaterEntry 54 } sensorWaterNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorWaterEntry 56 } --/* End of sensorWaterEntry */ --/* Begin of sensorSecurityEntry */ sensorSecurityTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorSecurityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 10 } sensorSecurityEntry OBJECT-TYPE SYNTAX SensorSecurityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorSecurityIndex } ::= { sensorSecurityTable 1 } SensorSecurityEntry ::= SEQUENCE { sensorSecurityIndex INTEGER, sensorSecurityDescription DisplayString, sensorSecurityStatus INTEGER, sensorSecurityGoOffline INTEGER, sensorSecurityPort INTEGER, sensorSecuritySubPort INTEGER, sensorSecurityDeviceIndex INTEGER, sensorSecurityCriticalDesc DisplayString, sensorSecurityNormalDesc DisplayString, sensorSecurityCriticalColor INTEGER, sensorSecurityNormalColor INTEGER } sensorSecurityIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorSecurityEntry 1 } sensorSecurityDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorSecurityEntry 2 } sensorSecurityStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorSecurityEntry 6 } sensorSecurityGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorSecurityEntry 8 } sensorSecurityPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorSecurityEntry 35 } sensorSecuritySubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorSecurityEntry 36 } sensorSecurityDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorSecurityEntry 37 } sensorSecurityCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Description of this sensor" ::= { sensorSecurityEntry 46 } sensorSecurityNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorSecurityEntry 48 } sensorSecurityCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Color of this sensor" ::= { sensorSecurityEntry 54 } sensorSecurityNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorSecurityEntry 56 } --/* End of sensorSecurityEntry */ --/* Begin of sensorSirenEntry */ sensorSirenTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorSirenEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 11 } sensorSirenEntry OBJECT-TYPE SYNTAX SensorSirenEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorSirenIndex } ::= { sensorSirenTable 1 } SensorSirenEntry ::= SEQUENCE { sensorSirenIndex INTEGER, sensorSirenDescription DisplayString, sensorSirenStatus INTEGER, sensorSirenGoOffline INTEGER, sensorSirenControlMode INTEGER, sensorSirenManualCycleTime INTEGER, sensorSirenManualAction INTEGER, sensorSirenPort INTEGER, sensorSirenSubPort INTEGER, sensorSirenDeviceIndex INTEGER, sensorSirenOnDesc DisplayString, sensorSirenOffDesc DisplayString, sensorSirenOnColor INTEGER, sensorSirenOffColor INTEGER } sensorSirenIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorSirenEntry 1 } sensorSirenDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorSirenEntry 2 } sensorSirenStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorSirenEntry 6 } sensorSirenGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorSirenEntry 8 } sensorSirenControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), sensor-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a siren." ::= { sensorSirenEntry 24 } sensorSirenManualCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Toggle period in seconds for Manual Cycle action." ::= { sensorSirenEntry 25 } sensorSirenManualAction OBJECT-TYPE SYNTAX INTEGER { turn-On(0), turn-Off(1), cycle-On-Off-On(2), cycle-Off-On-Off(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the siren manualy" ::= { sensorSirenEntry 26 } sensorSirenPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorSirenEntry 35 } sensorSirenSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorSirenEntry 36 } sensorSirenDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorSirenEntry 37 } sensorSirenOnDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A On Description of this sensor" ::= { sensorSirenEntry 52 } sensorSirenOffDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Off Description of this sensor" ::= { sensorSirenEntry 53 } sensorSirenOnColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A On Color of this sensor" ::= { sensorSirenEntry 60 } sensorSirenOffColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Off Color of this sensor" ::= { sensorSirenEntry 61 } --/* End of sensorSirenEntry */ --/* Begin of sensorRelayEntry */ sensorRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorRelayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 12 } sensorRelayEntry OBJECT-TYPE SYNTAX SensorRelayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorRelayIndex } ::= { sensorRelayTable 1 } SensorRelayEntry ::= SEQUENCE { sensorRelayIndex INTEGER, sensorRelayDescription DisplayString, sensorRelayType INTEGER, sensorRelayStatus INTEGER, sensorRelayGoOffline INTEGER, sensorRelayControlMode INTEGER, sensorRelayManualCycleTime INTEGER, sensorRelayManualAction INTEGER, sensorRelayPort INTEGER, sensorRelaySubPort INTEGER, sensorRelayDeviceIndex INTEGER, sensorRelayOnDesc DisplayString, sensorRelayOffDesc DisplayString, sensorRelayOnColor INTEGER, sensorRelayOffColor INTEGER } sensorRelayIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorRelayEntry 1 } sensorRelayDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorRelayEntry 2 } sensorRelayType OBJECT-TYPE SYNTAX INTEGER { relay(13), xrelay(19) } ACCESS read-only STATUS mandatory DESCRIPTION "Enter the type of this Sensor" ::= { sensorRelayEntry 3 } sensorRelayStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorRelayEntry 6 } sensorRelayGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorRelayEntry 8 } sensorRelayControlMode OBJECT-TYPE SYNTAX INTEGER { manual-control(0), sensor-control(1), time-control(2), thermostat-control(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control Mode used for selecting the mode to control a relay." ::= { sensorRelayEntry 24 } sensorRelayManualCycleTime OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Toggle period in seconds for Manual Cycle action." ::= { sensorRelayEntry 25 } sensorRelayManualAction OBJECT-TYPE SYNTAX INTEGER { turn-On(0), turn-Off(1), cycle-On-Off-On(2), cycle-Off-On-Off(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control the relay manualy" ::= { sensorRelayEntry 26 } sensorRelayPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorRelayEntry 35 } sensorRelaySubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorRelayEntry 36 } sensorRelayDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorRelayEntry 37 } sensorRelayOnDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A On Description of this sensor" ::= { sensorRelayEntry 52 } sensorRelayOffDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Off Description of this sensor" ::= { sensorRelayEntry 53 } sensorRelayOnColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A On Color of this sensor" ::= { sensorRelayEntry 60 } sensorRelayOffColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Off Color of this sensor" ::= { sensorRelayEntry 61 } --/* End of sensorRelayEntry */ --/* Begin of sensorACvoltageEntry */ sensorACvoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorACvoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 13 } sensorACvoltageEntry OBJECT-TYPE SYNTAX SensorACvoltageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorACvoltageIndex } ::= { sensorACvoltageTable 1 } SensorACvoltageEntry ::= SEQUENCE { sensorACvoltageIndex INTEGER, sensorACvoltageDescription DisplayString, sensorACvoltageStatus INTEGER, sensorACvoltageGoOffline INTEGER, sensorACvoltagePort INTEGER, sensorACvoltageSubPort INTEGER, sensorACvoltageDeviceIndex INTEGER, sensorACvoltageCriticalDesc DisplayString, sensorACvoltageNormalDesc DisplayString, sensorACvoltageCriticalColor INTEGER, sensorACvoltageNormalColor INTEGER } sensorACvoltageIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorACvoltageEntry 1 } sensorACvoltageDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorACvoltageEntry 2 } sensorACvoltageStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorACvoltageEntry 6 } sensorACvoltageGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To put online enter a 1, to take offline enter a 2" ::= { sensorACvoltageEntry 8 } sensorACvoltagePort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorACvoltageEntry 35 } sensorACvoltageSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorACvoltageEntry 36 } sensorACvoltageDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorACvoltageEntry 37 } sensorACvoltageCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Description of this sensor" ::= { sensorACvoltageEntry 46 } sensorACvoltageNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorACvoltageEntry 48 } sensorACvoltageCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Color of this sensor" ::= { sensorACvoltageEntry 54 } sensorACvoltageNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorACvoltageEntry 56 } --/* End of sensorACvoltageEntry */ --/* Begin of sensorSmokeEntry */ sensorSmokeTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorSmokeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 14 } sensorSmokeEntry OBJECT-TYPE SYNTAX SensorSmokeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorSmokeIndex } ::= { sensorSmokeTable 1 } SensorSmokeEntry ::= SEQUENCE { sensorSmokeIndex INTEGER, sensorSmokeDescription DisplayString, sensorSmokeStatus INTEGER, sensorSmokeGoOffline INTEGER, sensorSmokePort INTEGER, sensorSmokeSubPort INTEGER, sensorSmokeDeviceIndex INTEGER, sensorSmokeCriticalDesc DisplayString, sensorSmokeNormalDesc DisplayString, sensorSmokeCriticalColor INTEGER, sensorSmokeNormalColor INTEGER } sensorSmokeIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorSmokeEntry 1 } sensorSmokeDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorSmokeEntry 2 } sensorSmokeStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7), relayOn(8), relayOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorSmokeEntry 6 } sensorSmokeGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorSmokeEntry 8 } sensorSmokePort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorSmokeEntry 35 } sensorSmokeSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorSmokeEntry 36 } sensorSmokeDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorSmokeEntry 37 } sensorSmokeCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Description of this sensor" ::= { sensorSmokeEntry 46 } sensorSmokeNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorSmokeEntry 48 } sensorSmokeCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Color of this sensor" ::= { sensorSmokeEntry 54 } sensorSmokeNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorSmokeEntry 56 } --/* End of sensorSmokeEntry */ --/* Begin of sensorThermostatEntry */ sensorThermostatTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorThermostatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 20 } sensorThermostatEntry OBJECT-TYPE SYNTAX SensorThermostatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTemperatureEntry Table" INDEX { sensorThermostatIndex } ::= { sensorThermostatTable 1 } SensorThermostatEntry ::= SEQUENCE { sensorThermostatIndex INTEGER, sensorThermostatDescription DisplayString, sensorThermostatDegree INTEGER, sensorThermostatStatus INTEGER, sensorThermostatGoOffline INTEGER, sensorThermostatLowCritical INTEGER, sensorThermostatLowWarning INTEGER, sensorThermostatHighWarning INTEGER, sensorThermostatHighCritical INTEGER, sensorThermostatRearm INTEGER, sensorThermostatDelayError INTEGER, sensorThermostatDelayNormal INTEGER, sensorThermostatDelayLowCritical INTEGER, sensorThermostatDelayLowWarning INTEGER, sensorThermostatDelayHighWarning INTEGER, sensorThermostatDelayHighCritical INTEGER, sensorThermostatPort INTEGER, sensorThermostatSubPort INTEGER, sensorThermostatDeviceIndex INTEGER, sensorThermostatDisplayStyle INTEGER, sensorThermostatHighCriticalDesc DisplayString, sensorThermostatLowCriticalDesc DisplayString, sensorThermostatNormalDesc DisplayString, sensorThermostatLowWarningDesc DisplayString, sensorThermostatHighWarningDesc DisplayString, sensorThermostatSensorErrorDesc DisplayString, sensorThermostatHighCriticalColor INTEGER, sensorThermostatLowCriticalColor INTEGER, sensorThermostatNormalColor INTEGER, sensorThermostatLowWarningColor INTEGER, sensorThermostatHighWarningColor INTEGER, sensorThermostatSensorErrorColor INTEGER } sensorThermostatIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensorThermostatEntry 1 } sensorThermostatDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorThermostatEntry 2 } sensorThermostatDegree OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The degrees in this sensor" ::= { sensorThermostatEntry 4 } sensorThermostatStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorThermostatEntry 6 } sensorThermostatGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorThermostatEntry 8 } sensorThermostatLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { sensorThermostatEntry 9 } sensorThermostatLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { sensorThermostatEntry 10 } sensorThermostatHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { sensorThermostatEntry 11 } sensorThermostatHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { sensorThermostatEntry 12 } sensorThermostatRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorThermostatEntry 13 } sensorThermostatDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorThermostatEntry 14 } sensorThermostatDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorThermostatEntry 15 } sensorThermostatDelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensorThermostatEntry 16 } sensorThermostatDelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensorThermostatEntry 17 } sensorThermostatDelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensorThermostatEntry 18 } sensorThermostatDelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensorThermostatEntry 19 } sensorThermostatPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorThermostatEntry 35 } sensorThermostatSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorThermostatEntry 36 } sensorThermostatDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorThermostatEntry 37 } sensorThermostatDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Thermostat display style" ::= { sensorThermostatEntry 45 } sensorThermostatHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorThermostatEntry 46 } sensorThermostatLowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorThermostatEntry 47 } sensorThermostatNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorThermostatEntry 48 } sensorThermostatLowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorThermostatEntry 49 } sensorThermostatHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorThermostatEntry 50 } sensorThermostatSensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorThermostatEntry 51 } sensorThermostatHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorThermostatEntry 54 } sensorThermostatLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorThermostatEntry 55 } sensorThermostatNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorThermostatEntry 56 } sensorThermostatLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorThermostatEntry 57 } sensorThermostatHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorThermostatEntry 58 } sensorThermostatSensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorThermostatEntry 59 } --/* End of sensorThermostatEntry */ --/* Begin of sensorWaterRopeEntry */ sensorWaterRopeTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorWaterRopeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 21 } sensorWaterRopeEntry OBJECT-TYPE SYNTAX SensorWaterRopeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the SensorWaterRopeEntry Table" INDEX { sensorWaterRopeIndex } ::= { sensorWaterRopeTable 1 } SensorWaterRopeEntry ::= SEQUENCE { sensorWaterRopeIndex INTEGER, sensorWaterRopeDescription DisplayString, sensorWaterRopeLeakLocation INTEGER, sensorWaterRopeUnit DisplayString, sensorWaterRopeStatus INTEGER, sensorWaterRopeGoOffline INTEGER, sensorWaterRopeRaw INTEGER, sensorWaterRopeDeviceIndex INTEGER, sensorWaterRopeCriticalDesc DisplayString, sensorWaterRopeNormalDesc DisplayString, sensorWaterRopeSensorErrorDesc DisplayString, sensorWaterRopeCriticalColor INTEGER, sensorWaterRopeNormalColor INTEGER, sensorWaterRopeSensorErrorColor INTEGER, sensorWaterRopeLength INTEGER, sensorWaterRopeImpedance INTEGER, sensorWaterRopeType INTEGER } sensorWaterRopeIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensorWaterRopeEntry 1 } sensorWaterRopeDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorWaterRopeEntry 2 } sensorWaterRopeLeakLocation OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Location of leakage of water rope sensor." ::= { sensorWaterRopeEntry 4 } sensorWaterRopeUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Display unit of water rope sensor." ::= { sensorWaterRopeEntry 5 } sensorWaterRopeStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorWaterRopeEntry 6 } sensorWaterRopeGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorWaterRopeEntry 8 } sensorWaterRopeRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Raw value of location or length in ohms" ::= { sensorWaterRopeEntry 20 } sensorWaterRopeDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorWaterRopeEntry 37 } sensorWaterRopeCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Description of this sensor" ::= { sensorWaterRopeEntry 46 } sensorWaterRopeNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorWaterRopeEntry 48 } sensorWaterRopeSensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorWaterRopeEntry 51 } sensorWaterRopeCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Critical Color of this sensor" ::= { sensorWaterRopeEntry 54 } sensorWaterRopeNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorWaterRopeEntry 56 } sensorWaterRopeSensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorWaterRopeEntry 59 } sensorWaterRopeLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Length of water rope sensor." ::= { sensorWaterRopeEntry 100 } sensorWaterRopeImpedance OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Sensing wire impedance per meter value times 100" ::= { sensorWaterRopeEntry 101 } sensorWaterRopeType OBJECT-TYPE SYNTAX INTEGER { custom(0), water(1), fuel(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Water rope sensing cable type" ::= { sensorWaterRopeEntry 103 } --/* End of sensorWaterRopeEntry */ --/* Begin of sensorPowerEntry */ sensorPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 22 } sensorPowerEntry OBJECT-TYPE SYNTAX SensorPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorPowerEntry Table" INDEX { sensorPowerIndex } ::= { sensorPowerTable 1 } SensorPowerEntry ::= SEQUENCE { sensorPowerIndex INTEGER, sensorPowerDescription DisplayString, sensorPowerValue INTEGER, sensorPowerUnit DisplayString, sensorPowerStatus INTEGER, sensorPowerGoOffline INTEGER, sensorPowerLowCritical INTEGER, sensorPowerLowWarning INTEGER, sensorPowerHighWarning INTEGER, sensorPowerHighCritical INTEGER, sensorPowerRearm INTEGER, sensorPowerDelayError INTEGER, sensorPowerDelayNormal INTEGER, sensorPowerDelayLowCritical INTEGER, sensorPowerDelayLowWarning INTEGER, sensorPowerDelayHighWarning INTEGER, sensorPowerDelayHighCritical INTEGER, sensorPowerPort INTEGER, sensorPowerSubPort INTEGER, sensorPowerDeviceIndex INTEGER, sensorPowerTimeOut INTEGER, sensorPowerInterval INTEGER, sensorPowerErrorRetryNum INTEGER, sensorPowerMaxValue INTEGER, sensorPowerMinValue INTEGER, sensorPowerDisplayStyle INTEGER, sensorPowerHighCriticalDesc DisplayString, sensorPowerLowCriticalDesc DisplayString, sensorPowerNormalDesc DisplayString, sensorPowerLowWarningDesc DisplayString, sensorPowerHighWarningDesc DisplayString, sensorPowerSensorErrorDesc DisplayString, sensorPowerHighCriticalColor INTEGER, sensorPowerLowCriticalColor INTEGER, sensorPowerNormalColor INTEGER, sensorPowerLowWarningColor INTEGER, sensorPowerHighWarningColor INTEGER, sensorPowerSensorErrorColor INTEGER } sensorPowerIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Switch sensor table" ::= { sensorPowerEntry 1 } sensorPowerDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor Switch" ::= { sensorPowerEntry 2 } sensorPowerValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The reading value in this sensor" ::= { sensorPowerEntry 4 } sensorPowerUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The unit string" ::= { sensorPowerEntry 5 } sensorPowerStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highCritical(4), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor, only input switches have a status" ::= { sensorPowerEntry 6 } sensorPowerGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorPowerEntry 8 } sensorPowerLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a critical event" ::= { sensorPowerEntry 9 } sensorPowerLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How cold this sensor gets before it sends a warning" ::= { sensorPowerEntry 10 } sensorPowerHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a warning" ::= { sensorPowerEntry 11 } sensorPowerHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "How hot this sensor gets before it sends a critical event" ::= { sensorPowerEntry 12 } sensorPowerRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorPowerEntry 13 } sensorPowerDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorPowerEntry 14 } sensorPowerDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorPowerEntry 15 } sensorPowerDelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensorPowerEntry 16 } sensorPowerDelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensorPowerEntry 17 } sensorPowerDelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensorPowerEntry 18 } sensorPowerDelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensorPowerEntry 19 } sensorPowerPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor port" ::= { sensorPowerEntry 35 } sensorPowerSubPort OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor sub port" ::= { sensorPowerEntry 36 } sensorPowerDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorPowerEntry 37 } sensorPowerTimeOut OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "The polling timeout of Power Sensor." ::= { sensorPowerEntry 38 } sensorPowerInterval OBJECT-TYPE SYNTAX INTEGER (5..720) ACCESS read-write STATUS mandatory DESCRIPTION "The polling interval of Power Sensor." ::= { sensorPowerEntry 39 } sensorPowerErrorRetryNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of retry before error." ::= { sensorPowerEntry 40 } sensorPowerMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum scale of Power value." ::= { sensorPowerEntry 41 } sensorPowerMinValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The minimum scale of Power value." ::= { sensorPowerEntry 42 } sensorPowerDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Power display style." ::= { sensorPowerEntry 45 } sensorPowerHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorPowerEntry 46 } sensorPowerLowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorPowerEntry 47 } sensorPowerNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorPowerEntry 48 } sensorPowerLowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorPowerEntry 49 } sensorPowerHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorPowerEntry 50 } sensorPowerSensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorPowerEntry 51 } sensorPowerHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorPowerEntry 54 } sensorPowerLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorPowerEntry 55 } sensorPowerNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorPowerEntry 56 } sensorPowerLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorPowerEntry 57 } sensorPowerHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorPowerEntry 58 } sensorPowerSensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorPowerEntry 59 } --/* End of sensorPowerEntry */ --/* Begin of sensorFuelEntry */ sensorFuelTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorFuelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 24 } sensorFuelEntry OBJECT-TYPE SYNTAX SensorFuelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the SensorFuelEntry Table" INDEX { sensorFuelIndex } ::= { sensorFuelTable 1 } SensorFuelEntry ::= SEQUENCE { sensorFuelIndex INTEGER, sensorFuelDescription DisplayString, sensorFuelValue INTEGER, sensorFuelUnit DisplayString, sensorFuelStatus INTEGER, sensorFuelGoOffline INTEGER, sensorFuelLowCritical INTEGER, sensorFuelLowWarning INTEGER, sensorFuelHighWarning INTEGER, sensorFuelHighCritical INTEGER, sensorFuelRearm INTEGER, sensorFuelDelayError INTEGER, sensorFuelDelayNormal INTEGER, sensorFuelDelayLowCritical INTEGER, sensorFuelDelayLowWarning INTEGER, sensorFuelDelayHighWarning INTEGER, sensorFuelDelayHighCritical INTEGER, sensorFuelRaw INTEGER, sensorFuelAmountMaxValue INTEGER, sensorFuelAmountBaseValue INTEGER, sensorFuelDeviceIndex INTEGER, sensorFuelDisplayStyle INTEGER, sensorFuelHighCriticalDesc DisplayString, sensorFuelLowCriticalDesc DisplayString, sensorFuelNormalDesc DisplayString, sensorFuelLowWarningDesc DisplayString, sensorFuelHighWarningDesc DisplayString, sensorFuelSensorErrorDesc DisplayString, sensorFuelHighCriticalColor INTEGER, sensorFuelLowCriticalColor INTEGER, sensorFuelNormalColor INTEGER, sensorFuelLowWarningColor INTEGER, sensorFuelHighWarningColor INTEGER, sensorFuelSensorErrorColor INTEGER } sensorFuelIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensorFuelEntry 1 } sensorFuelDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorFuelEntry 2 } sensorFuelValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The reading value in this sensor" ::= { sensorFuelEntry 4 } sensorFuelUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The unit string" ::= { sensorFuelEntry 5 } sensorFuelStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorFuelEntry 6 } sensorFuelGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorFuelEntry 8 } sensorFuelLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Level value of this sensor gets before it sends a critical event" ::= { sensorFuelEntry 9 } sensorFuelLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Level value of this sensor gets before it sends a warning" ::= { sensorFuelEntry 10 } sensorFuelHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Level value of this sensor gets before it sends a warning" ::= { sensorFuelEntry 11 } sensorFuelHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Level value of this sensor gets before it sends a critical event" ::= { sensorFuelEntry 12 } sensorFuelRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorFuelEntry 13 } sensorFuelDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorFuelEntry 14 } sensorFuelDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorFuelEntry 15 } sensorFuelDelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensorFuelEntry 16 } sensorFuelDelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensorFuelEntry 17 } sensorFuelDelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensorFuelEntry 18 } sensorFuelDelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensorFuelEntry 19 } sensorFuelRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage." ::= { sensorFuelEntry 20 } sensorFuelAmountMaxValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum scale of value conversion." ::= { sensorFuelEntry 33 } sensorFuelAmountBaseValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The base scale of value conversion." ::= { sensorFuelEntry 34 } sensorFuelDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorFuelEntry 37 } sensorFuelDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Fuel display style" ::= { sensorFuelEntry 45 } sensorFuelHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorFuelEntry 46 } sensorFuelLowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorFuelEntry 47 } sensorFuelNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorFuelEntry 48 } sensorFuelLowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorFuelEntry 49 } sensorFuelHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorFuelEntry 50 } sensorFuelSensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorFuelEntry 51 } sensorFuelHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorFuelEntry 54 } sensorFuelLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorFuelEntry 55 } sensorFuelNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorFuelEntry 56 } sensorFuelLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorFuelEntry 57 } sensorFuelHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorFuelEntry 58 } sensorFuelSensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorFuelEntry 59 } --/* End of sensorFuelEntry */ --/* Begin of sensorTankSenderEntry */ sensorTankSenderTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorTankSenderEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the property and reading value for every sensor." ::= { secSensor 26 } sensorTankSenderEntry OBJECT-TYPE SYNTAX SensorTankSenderEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the sensorTankSenderEntry Table" INDEX { sensorTankSenderIndex } ::= { sensorTankSenderTable 1 } SensorTankSenderEntry ::= SEQUENCE { sensorTankSenderIndex INTEGER, sensorTankSenderDescription DisplayString, sensorTankSenderValue INTEGER, sensorTankSenderUnit DisplayString, sensorTankSenderStatus INTEGER, sensorTankSenderGoOffline INTEGER, sensorTankSenderLowCritical INTEGER, sensorTankSenderLowWarning INTEGER, sensorTankSenderHighWarning INTEGER, sensorTankSenderHighCritical INTEGER, sensorTankSenderRearm INTEGER, sensorTankSenderDelayError INTEGER, sensorTankSenderDelayNormal INTEGER, sensorTankSenderDelayLowCritical INTEGER, sensorTankSenderDelayLowWarning INTEGER, sensorTankSenderDelayHighWarning INTEGER, sensorTankSenderDelayHighCritical INTEGER, sensorTankSenderRaw INTEGER, sensorTankSenderDeviceIndex INTEGER, sensorTankSenderDisplayStyle INTEGER, sensorTankSenderHighCriticalDesc DisplayString, sensorTankSenderLowCriticalDesc DisplayString, sensorTankSenderNormalDesc DisplayString, sensorTankSenderLowWarningDesc DisplayString, sensorTankSenderHighWarningDesc DisplayString, sensorTankSenderSensorErrorDesc DisplayString, sensorTankSenderHighCriticalColor INTEGER, sensorTankSenderLowCriticalColor INTEGER, sensorTankSenderNormalColor INTEGER, sensorTankSenderLowWarningColor INTEGER, sensorTankSenderHighWarningColor INTEGER, sensorTankSenderSensorErrorColor INTEGER } sensorTankSenderIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index into the sensor table" ::= { sensorTankSenderEntry 1 } sensorTankSenderDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Description of this sensor" ::= { sensorTankSenderEntry 2 } sensorTankSenderValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The reading value in this sensor" ::= { sensorTankSenderEntry 4 } sensorTankSenderUnit OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The unit string" ::= { sensorTankSenderEntry 5 } sensorTankSenderStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of this Sensor" ::= { sensorTankSenderEntry 6 } sensorTankSenderGoOffline OBJECT-TYPE SYNTAX INTEGER { online(1), goOffline(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To take offline enter a 2" ::= { sensorTankSenderEntry 8 } sensorTankSenderLowCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Level value of this sensor gets before it sends a critical event" ::= { sensorTankSenderEntry 9 } sensorTankSenderLowWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Level value of this sensor gets before it sends a warning" ::= { sensorTankSenderEntry 10 } sensorTankSenderHighWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Level value of this sensor gets before it sends a warning" ::= { sensorTankSenderEntry 11 } sensorTankSenderHighCritical OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Level value of this sensor gets before it sends a critical event" ::= { sensorTankSenderEntry 12 } sensorTankSenderRearm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal" ::= { sensorTankSenderEntry 13 } sensorTankSenderDelayError OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor has been in error status before report as an error" ::= { sensorTankSenderEntry 14 } sensorTankSenderDelayNormal OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-write STATUS mandatory DESCRIPTION "Time in seconds after the sensor change from error to normal before report as normal" ::= { sensorTankSenderEntry 15 } sensorTankSenderDelayLowCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Critical before accepting new Status." ::= { sensorTankSenderEntry 16 } sensorTankSenderDelayLowWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in Low Warning before accepting new Status." ::= { sensorTankSenderEntry 17 } sensorTankSenderDelayHighWarning OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Warning before accepting new Status." ::= { sensorTankSenderEntry 18 } sensorTankSenderDelayHighCritical OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Continuous time for this sensor to be in High Critical before accepting new Status." ::= { sensorTankSenderEntry 19 } sensorTankSenderRaw OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage." ::= { sensorTankSenderEntry 20 } sensorTankSenderDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device Index of sensor" ::= { sensorTankSenderEntry 37 } sensorTankSenderDisplayStyle OBJECT-TYPE SYNTAX INTEGER { basic(0), gauge(1) } ACCESS read-write STATUS mandatory DESCRIPTION "TankSender display style" ::= { sensorTankSenderEntry 45 } sensorTankSenderHighCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Description of this sensor" ::= { sensorTankSenderEntry 46 } sensorTankSenderLowCriticalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Description of this sensor" ::= { sensorTankSenderEntry 47 } sensorTankSenderNormalDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Description of this sensor" ::= { sensorTankSenderEntry 48 } sensorTankSenderLowWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Description of this sensor" ::= { sensorTankSenderEntry 49 } sensorTankSenderHighWarningDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Description of this sensor" ::= { sensorTankSenderEntry 50 } sensorTankSenderSensorErrorDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Description of this sensor" ::= { sensorTankSenderEntry 51 } sensorTankSenderHighCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighCritical Color of this sensor" ::= { sensorTankSenderEntry 54 } sensorTankSenderLowCriticalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowCritical Color of this sensor" ::= { sensorTankSenderEntry 55 } sensorTankSenderNormalColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A Normal Color of this sensor" ::= { sensorTankSenderEntry 56 } sensorTankSenderLowWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A LowWarning Color of this sensor" ::= { sensorTankSenderEntry 57 } sensorTankSenderHighWarningColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A HighWarning Color of this sensor" ::= { sensorTankSenderEntry 58 } sensorTankSenderSensorErrorColor OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A SensorError Color of this sensor" ::= { sensorTankSenderEntry 59 } --/* End of sensorTankSenderEntry */ -- -- Varbinds used in TRAP Definitions -- ramosOptimaTraps OBJECT IDENTIFIER ::= { ramosOptima 7 } spSensorStatus OBJECT-TYPE SYNTAX INTEGER { noStatus(1), normal(2), highWarning(3), highCritical(4), lowWarning(5), lowCritical(6), sensorError(7), turnOn(8), turnOff(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current integer status of the sensor causing this trap to be sent" ::= { ramosOptimaTraps 1 } spSensorValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current integer value of the sensor causing this trap to be sent" ::= { ramosOptimaTraps 2 } spSensorLevelExceeded OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The integer level that was exceeded causing this trap to be sent" ::= { ramosOptimaTraps 3 } spSensorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The integer index of the sensor causing this trap to be sent" ::= { ramosOptimaTraps 4 } spSensorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the sensor causing this trap to be sent" ::= { ramosOptimaTraps 5 } spSensorDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The description of the sensor causing this trap to be sent" ::= { ramosOptimaTraps 6 } spRamosOptimaKeepAlive OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Keep alive trap to be sent" ::= { ramosOptimaTraps 7 } spSensorType OBJECT-TYPE SYNTAX INTEGER { temperature(1), fourTo20mA(2), humidity(3), water(4), atod(5), security(6), airflow(8), siren(9), dryContact(10), voltage(12), relay(13), motion(14), extradrycontact(16), thermostat(23), smoke(24), power(25), irms(26), vrms(27), watt(28), relayarray(29), virtual(30), watthour(32), temperaturearray(33), waterrope(34), fuellevel(35), tanksender(36), sound(128), softwaremotion(129), nosignal(132), powermeter(134) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of this sensor" ::= { ramosOptimaTraps 8 } spSensorStatusName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the sensor causing this trap to be sent" ::= { ramosOptimaTraps 9 } spSensorSubIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The integer sub index of the sensor causing this trap to be sent. Only for temperaturearray and relayarray" ::= { ramosOptimaTraps 10 } spBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The integer index of the sensor board causing this trap to be sent." ::= { ramosOptimaTraps 11 } spBoardDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The description of the sensor board causing this trap to be sent" ::= { ramosOptimaTraps 12 } spEventTimeStamp OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The time(MM/DD/YYYY HH:MM:SS) of an event causing this trap to be sent" ::= { ramosOptimaTraps 13 } spEventClassNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The user-defined class number associated with this trap" ::= { ramosOptimaTraps 14 } spEventClassName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The user-defined class Name associated with this trap" ::= { ramosOptimaTraps 15 } spSensorDecimalValue OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The current decimal value of the sensor causing this trap to be sent" ::= { ramosOptimaTraps 16 } spSensorAliveHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The highest sensor value in the period" ::= { ramosOptimaTraps 17 } spSensorAliveLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The lowset sensor value in the period" ::= { ramosOptimaTraps 18 } -- TRAP Definitions spNormalStatus TRAP-TYPE ENTERPRISE ramosOptima DESCRIPTION "ramosOptima status is Normal" --#TYPE "ramosOptima Normal Status" --#SEVERITY INFORMATIONAL ::= 1 spWarningStatus TRAP-TYPE ENTERPRISE ramosOptima DESCRIPTION "ramosOptima status went to Warning" --#TYPE "ramosOptima Warning Status" --#SEVERITY MINOR ::= 2 spCriticalStatus TRAP-TYPE ENTERPRISE ramosOptima DESCRIPTION "ramosOptima status went to Critical" --#TYPE "ramosOptima Critical Status" --#SEVERITY MAJOR ::= 3 spDownStatus TRAP-TYPE ENTERPRISE ramosOptima DESCRIPTION "ramosOptima status went to Disabled" --#TYPE "ramosOptima Down Status" --#SEVERITY MINOR ::= 4 spKeepAliveTrap TRAP-TYPE ENTERPRISE ramosOptima DESCRIPTION "ramosOptima send keep alive trap." --#SEVERITY INFORMATIONAL ::= 5 spUnknownStatus TRAP-TYPE ENTERPRISE ramosOptima DESCRIPTION "ramosOptima status went to Unknown" --#TYPE "ramosOptima Unknown Status" --#SEVERITY INFORMATIONAL ::= 7 -- ramosOptimaTrapType = generalTypeTrap(2) spTemperatureStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 10 spTemperatureArray1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 11 spTemperatureArray2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 12 spTemperatureArray3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 13 spTemperatureArray4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 14 spTemperatureArray5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 15 spTemperatureArray6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 16 spTemperatureArray7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 17 spTemperatureArray8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 18 spAnalogueStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 20 spSwitchStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 30 spIRMSStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 40 spVRMSStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 50 spWattStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 60 spRelayArray1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1 sensor trap" --#SEVERITY MAJOR ::= 71 spRelayArray2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2 sensor trap" --#SEVERITY MAJOR ::= 72 spRelayArray3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3 sensor trap" --#SEVERITY MAJOR ::= 73 spRelayArray4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4 sensor trap" --#SEVERITY MAJOR ::= 74 spRelayArray5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5 sensor trap" --#SEVERITY MAJOR ::= 75 spRelayArray6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6 sensor trap" --#SEVERITY MAJOR ::= 77 spRelayArray8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8 sensor trap" --#SEVERITY MAJOR ::= 78 spVirtualStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual sensor trap" --#SEVERITY MAJOR ::= 80 -- ramosOptimaTrapType = statusTypeTraps(4) spSenUnknownStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "ramosOptima sensor status went to Unknown" --#TYPE "ramosOptima Unknown Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY MAJOR --#TIMEINDEX 4 ::= 51 spSenNormalStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "ramosOptima sensor status is Normal" --#TYPE "ramosOptima Normal Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 4 ::= 52 spSenWarningStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "ramosOptima sensor status went to Warning" --#TYPE "ramosOptima Warning Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY MINOR --#TIMEINDEX 4 ::= 53 spSenCriticalStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "ramosOptima sensor status went to Critical" --#TYPE "ramosOptima Critical Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY MAJOR --#TIMEINDEX 4 ::= 54 spSenDownStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "ramosOptima sensor status went to Disabled" --#TYPE "ramosOptima Down Status" --#SUMMARY "%s(%s) Status is now %d on port %d." --#ARGUMENTS {4,5,1,3} --#SEVERITY INFORMATIONAL --#TIMEINDEX 4 ::= 55 -- ramosOptimaTrapType = specificTypeTrap(1) spTemperature1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 101 spTemperature2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 102 spTemperature3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 103 spTemperature4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 104 spTemperature5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 105 spTemperature6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 106 spTemperature7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 107 spTemperature8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 108 spTemperatureArray1-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 111 spTemperatureArray1-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 112 spTemperatureArray1-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 113 spTemperatureArray1-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 114 spTemperatureArray1-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 115 spTemperatureArray1-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 116 spTemperatureArray1-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 117 spTemperatureArray1-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 118 spTemperatureArray2-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 121 spTemperatureArray2-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 122 spTemperatureArray2-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 123 spTemperatureArray2-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 124 spTemperatureArray2-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 125 spTemperatureArray2-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 126 spTemperatureArray2-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 127 spTemperatureArray2-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 128 spTemperatureArray3-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 131 spTemperatureArray3-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 132 spTemperatureArray3-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 133 spTemperatureArray3-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 134 spTemperatureArray3-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 135 spTemperatureArray3-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 136 spTemperatureArray3-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 137 spTemperatureArray3-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 138 spTemperatureArray4-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 141 spTemperatureArray4-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 142 spTemperatureArray4-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 143 spTemperatureArray4-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 144 spTemperatureArray4-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 145 spTemperatureArray4-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 146 spTemperatureArray4-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 147 spTemperatureArray4-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 148 spTemperatureArray5-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 151 spTemperatureArray5-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 152 spTemperatureArray5-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 153 spTemperatureArray5-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 154 spTemperatureArray5-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 155 spTemperatureArray5-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 156 spTemperatureArray5-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 157 spTemperatureArray5-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 158 spTemperatureArray6-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 161 spTemperatureArray6-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 162 spTemperatureArray6-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 163 spTemperatureArray6-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 164 spTemperatureArray6-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 165 spTemperatureArray6-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 166 spTemperatureArray6-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 167 spTemperatureArray6-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 168 spTemperatureArray7-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 171 spTemperatureArray7-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 172 spTemperatureArray7-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 173 spTemperatureArray7-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 174 spTemperatureArray7-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 175 spTemperatureArray7-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 176 spTemperatureArray7-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 177 spTemperatureArray7-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 178 spTemperatureArray8-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 181 spTemperatureArray8-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 182 spTemperatureArray8-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 183 spTemperatureArray8-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 184 spTemperatureArray8-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 185 spTemperatureArray8-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 186 spTemperatureArray8-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 187 spTemperatureArray8-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Temperature sensor trap" --#SEVERITY MAJOR ::= 188 spAnalogue1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 201 spAnalogue2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 202 spAnalogue3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 203 spAnalogue4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 204 spAnalogue5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 205 spAnalogue6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 206 spAnalogue7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 207 spAnalogue8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Analogue Sensor Type" --#SEVERITY MAJOR ::= 208 spSwitch1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 301 spSwitch2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 302 spSwitch3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 303 spSwitch4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 304 spSwitch5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 305 spSwitch6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 306 spSwitch7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 307 spSwitch8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 308 spSwitch9Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 309 spSwitch10Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 310 spSwitch11Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 311 spSwitch12Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 312 spSwitch13Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 313 spSwitch14Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 314 spSwitch15Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 315 spSwitch16Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 316 spSwitch17Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 317 spSwitch18Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 318 spSwitch19Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 319 spSwitch20Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 320 spSwitch21Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 321 spSwitch22Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 322 spSwitch23Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 323 spSwitch24Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 324 spSwitch25Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 325 spSwitch26Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 326 spSwitch27Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 327 spSwitch28Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 328 spSwitch29Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 329 spSwitch30Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 330 spSwitch31Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 331 spSwitch32Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 332 spSwitch33Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 333 spSwitch34Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 334 spSwitch35Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 335 spSwitch36Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 336 spSwitch37Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 337 spSwitch38Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 338 spSwitch39Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 339 spSwitch40Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 340 spSwitch41Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 341 spSwitch42Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 342 spSwitch43Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 343 spSwitch44Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 344 spSwitch45Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 345 spSwitch46Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 346 spSwitch47Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 347 spSwitch48Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 348 spSwitch49Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 349 spSwitch50Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 350 spSwitch51Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 351 spSwitch52Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 352 spSwitch53Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 353 spSwitch54Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 354 spSwitch55Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 355 spSwitch56Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 356 spSwitch57Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 357 spSwitch58Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 358 spSwitch59Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 359 spSwitch60Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 360 spSwitch61Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 361 spSwitch62Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 362 spSwitch63Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 363 spSwitch64Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 364 spSwitch65Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 365 spSwitch66Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 366 spSwitch67Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 367 spSwitch68Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Switch sensor trap" --#SEVERITY MAJOR ::= 368 spIRMS1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 401 spIRMS2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 402 spIRMS3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 403 spIRMS4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 404 spIRMS5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 405 spIRMS6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 406 spIRMS7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 407 spIRMS8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "IRMS sensor trap" --#SEVERITY MAJOR ::= 408 spVRMS1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 501 spVRMS2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 502 spVRMS3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 503 spVRMS4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 504 spVRMS5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 505 spVRMS6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 506 spVRMS7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 507 spVRMS8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "VRMS sensor trap" --#SEVERITY MAJOR ::= 508 spEnergy1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 601 spEnergy2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 602 spEnergy3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 603 spEnergy4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 604 spEnergy5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 605 spEnergy6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 606 spEnergy7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 607 spEnergy8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Energy sensor trap" --#SEVERITY MAJOR ::= 608 spRelayArray1-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1.1 sensor trap" --#SEVERITY MAJOR ::= 711 spRelayArray1-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1.2 sensor trap" --#SEVERITY MAJOR ::= 712 spRelayArray1-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1.3 sensor trap" --#SEVERITY MAJOR ::= 713 spRelayArray1-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1.4 sensor trap" --#SEVERITY MAJOR ::= 714 spRelayArray1-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1.5 sensor trap" --#SEVERITY MAJOR ::= 715 spRelayArray1-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1.6 sensor trap" --#SEVERITY MAJOR ::= 716 spRelayArray1-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1.7 sensor trap" --#SEVERITY MAJOR ::= 717 spRelayArray1-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray1.8 sensor trap" --#SEVERITY MAJOR ::= 718 spRelayArray2-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2.1 sensor trap" --#SEVERITY MAJOR ::= 721 spRelayArray2-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2.2 sensor trap" --#SEVERITY MAJOR ::= 722 spRelayArray2-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2.3 sensor trap" --#SEVERITY MAJOR ::= 723 spRelayArray2-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2.4 sensor trap" --#SEVERITY MAJOR ::= 724 spRelayArray2-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2.5 sensor trap" --#SEVERITY MAJOR ::= 725 spRelayArray2-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2.6 sensor trap" --#SEVERITY MAJOR ::= 726 spRelayArray2-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2.7 sensor trap" --#SEVERITY MAJOR ::= 727 spRelayArray2-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray2.8 sensor trap" --#SEVERITY MAJOR ::= 728 spRelayArray3-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3.1 sensor trap" --#SEVERITY MAJOR ::= 731 spRelayArray3-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3.2 sensor trap" --#SEVERITY MAJOR ::= 732 spRelayArray3-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3.3 sensor trap" --#SEVERITY MAJOR ::= 733 spRelayArray3-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3.4 sensor trap" --#SEVERITY MAJOR ::= 734 spRelayArray3-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3.5 sensor trap" --#SEVERITY MAJOR ::= 735 spRelayArray3-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3.6 sensor trap" --#SEVERITY MAJOR ::= 736 spRelayArray3-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3.7 sensor trap" --#SEVERITY MAJOR ::= 737 spRelayArray3-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray3.8 sensor trap" --#SEVERITY MAJOR ::= 738 spRelayArray4-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4.1 sensor trap" --#SEVERITY MAJOR ::= 741 spRelayArray4-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4.2 sensor trap" --#SEVERITY MAJOR ::= 742 spRelayArray4-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4.3 sensor trap" --#SEVERITY MAJOR ::= 743 spRelayArray4-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4.4 sensor trap" --#SEVERITY MAJOR ::= 744 spRelayArray4-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4.5 sensor trap" --#SEVERITY MAJOR ::= 745 spRelayArray4-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4.6 sensor trap" --#SEVERITY MAJOR ::= 746 spRelayArray4-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4.7 sensor trap" --#SEVERITY MAJOR ::= 747 spRelayArray4-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray4.8 sensor trap" --#SEVERITY MAJOR ::= 748 spRelayArray5-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5.1 sensor trap" --#SEVERITY MAJOR ::= 751 spRelayArray5-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5.2 sensor trap" --#SEVERITY MAJOR ::= 752 spRelayArray5-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5.3 sensor trap" --#SEVERITY MAJOR ::= 753 spRelayArray5-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5.4 sensor trap" --#SEVERITY MAJOR ::= 754 spRelayArray5-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5.5 sensor trap" --#SEVERITY MAJOR ::= 755 spRelayArray5-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5.6 sensor trap" --#SEVERITY MAJOR ::= 756 spRelayArray5-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5.7 sensor trap" --#SEVERITY MAJOR ::= 757 spRelayArray5-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray5.8 sensor trap" --#SEVERITY MAJOR ::= 758 spRelayArray6-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6.1 sensor trap" --#SEVERITY MAJOR ::= 761 spRelayArray6-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6.2 sensor trap" --#SEVERITY MAJOR ::= 762 spRelayArray6-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6.3 sensor trap" --#SEVERITY MAJOR ::= 763 spRelayArray6-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6.4 sensor trap" --#SEVERITY MAJOR ::= 764 spRelayArray6-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6.5 sensor trap" --#SEVERITY MAJOR ::= 765 spRelayArray6-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6.6 sensor trap" --#SEVERITY MAJOR ::= 766 spRelayArray6-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6.7 sensor trap" --#SEVERITY MAJOR ::= 767 spRelayArray6-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray6.8 sensor trap" --#SEVERITY MAJOR ::= 768 spRelayArray7-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray7.1 sensor trap" --#SEVERITY MAJOR ::= 771 spRelayArray7-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray7.2 sensor trap" --#SEVERITY MAJOR ::= 772 spRelayArray7-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray7.3 sensor trap" --#SEVERITY MAJOR ::= 773 spRelayArray7-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray7.4 sensor trap" --#SEVERITY MAJOR ::= 774 spRelayArray7-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray7.5 sensor trap" --#SEVERITY MAJOR ::= 775 spRelayArray7-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray7.6 sensor trap" --#SEVERITY MAJOR ::= 776 spRelayArray7-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray7.7 sensor trap" --#SEVERITY MAJOR ::= 777 spRelayArray7-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray7.8 sensor trap" --#SEVERITY MAJOR ::= 778 spRelayArray8-1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8.1 sensor trap" --#SEVERITY MAJOR ::= 781 spRelayArray8-2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8.2 sensor trap" --#SEVERITY MAJOR ::= 782 spRelayArray8-3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8.3 sensor trap" --#SEVERITY MAJOR ::= 783 spRelayArray8-4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8.4 sensor trap" --#SEVERITY MAJOR ::= 784 spRelayArray8-5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8.5 sensor trap" --#SEVERITY MAJOR ::= 785 spRelayArray8-6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8.6 sensor trap" --#SEVERITY MAJOR ::= 786 spRelayArray8-7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8.7 sensor trap" --#SEVERITY MAJOR ::= 787 spRelayArray8-8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "RelayArray8.8 sensor trap" --#SEVERITY MAJOR ::= 788 spVirtual1Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual1 sensor trap" --#SEVERITY MAJOR ::= 801 spVirtual2Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual2 sensor trap" --#SEVERITY MAJOR ::= 802 spVirtual3Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual3 sensor trap" --#SEVERITY MAJOR ::= 803 spVirtual4Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual4 sensor trap" --#SEVERITY MAJOR ::= 804 spVirtual5Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual5 sensor trap" --#SEVERITY MAJOR ::= 805 spVirtual6Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual6 sensor trap" --#SEVERITY MAJOR ::= 806 spVirtual7Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual7 sensor trap" --#SEVERITY MAJOR ::= 807 spVirtual8Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual8 sensor trap" --#SEVERITY MAJOR ::= 808 spVirtual9Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual9 sensor trap" --#SEVERITY MAJOR ::= 809 spVirtual10Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual10 sensor trap" --#SEVERITY MAJOR ::= 810 spVirtual11Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual11 sensor trap" --#SEVERITY MAJOR ::= 811 spVirtual12Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual12 sensor trap" --#SEVERITY MAJOR ::= 812 spVirtual13Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual13 sensor trap" --#SEVERITY MAJOR ::= 813 spVirtual14Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual14 sensor trap" --#SEVERITY MAJOR ::= 814 spVirtual15Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual15 sensor trap" --#SEVERITY MAJOR ::= 815 spVirtual16Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual16 sensor trap" --#SEVERITY MAJOR ::= 816 spVirtual17Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual17 sensor trap" --#SEVERITY MAJOR ::= 817 spVirtual18Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual18 sensor trap" --#SEVERITY MAJOR ::= 818 spVirtual19Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual19 sensor trap" --#SEVERITY MAJOR ::= 819 spVirtual20Status TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription } DESCRIPTION "Virtual20 sensor trap" --#SEVERITY MAJOR ::= 820 spCustomStatus TRAP-TYPE ENTERPRISE ramosOptima VARIABLES { spSensorStatus, spSensorValue, spSensorLevelExceeded, spSensorIndex, spSensorName, spSensorDescription, spSensorType, spSensorStatusName, spSensorSubIndex, spBoardIndex, spBoardDescription, spEventTimeStamp, spEventClassNumber, spEventClassName } DESCRIPTION "Custom sensor trap" --#SEVERITY MAJOR ::= 1000 END